Volvo Ingersoll Rand SD-116 TF Series Operator's Manual page 219

Table of Contents

Advertisement

FUEL AND LUBE SPECIFICATIONS
To prevent minor irregularities from developing into serious conditions, the following other
services or checks are recommended for the same intervals as the periodic lubrication:
1. Thoroughly wash all fittings, caps, plugs, etc. with non-flammable, non-toxic
cleaning solution before servicing to prevent dirt from entering while performing
the service.
2. Lubricants must be at operating temperature when draining.
3. During regular lubrication service, visually check the entire unit to ensure that
capscrews, nuts and pins are properly secured.
4. Spot check several capscrews and nuts for proper torque. If any are found
loose, a more thorough investigation must be made.
5. If a defect is detected which requires special maintenance service, stop the
machine operation until the defect has been corrected. If necessary, contact
the local Ingersoll Rand distributor for assistance.
6. This symbol
Periodic lubrication requirements are listed in the following Lubrication Chart. These
requirements include lubricant checks and greasing designated areas of the machine
SD-116F/DX/122D/F/DX/160F/DX/190DX/200F/DX
represents an area where lubrication is required.
SECTION 8
8-3