B&R Automation Panel 1000 User Manual page 164

Table of Contents

Advertisement

Accessories
Model number
Transfer properties
Insulation resistance
Operating conditions
Pollution degree per EN 61131-2
Flame-retardant
Oil and hydrolysis resistance
Degree of protection per EN 60529
Cables
RJ45 connector
Ambient conditions
Temperature
Storage
Fixed installation
Flexible installation
Mechanical properties
Dimensions
Length
Diameter
Bend radius
Fixed installation
Flexible installation
Weight
Tension
In operation
During installation
Table 67: 5CASD3.0030-00, 5CASD3.0050-00, 5CASD3.0100-00, 5CASD3.0150-00,
5CASD3.0200-00, 5CASD3.0300-00, 5CASD3.0500-00, 5CASD3.1000-00 - Technical data
1)
Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
At 20°C ambient temperature.
9.4.6.1.4 Bend radius specification
9.4.6.1.5 Dimensions
164
5CASD3.
5CASD3.
5CASD3.
0030-00
0050-00
0100-00
Category 6A / Class EA up to 500 MHz per ISO/IEC
11801 (EN 50173-1), ISO/IEC 24702 (EN 50173-3)
≥500 MΩ/km
-40 to 70°C
3 m
5 m
10 m
6.7 mm
≥5x diameter
≥10x diameter
250 g
500 g
≤70 N
≤70 N
Connector
Bend radius
Figure 91: SDL3/SDL4 - Bend radius specification
Length
Figure 92: 5CASD3.xxxx-00 - Dimensions
5CASD3.
5CASD3.
0150-00
0200-00
Pollution degree 2
IEC 60332-1-2
EN 60811-2-1 (90°C / 7x24 h)
IP20
IP20, only when properly connected
-40 to 70°C
-40 to 70°C
15 m
20 m
700 g
950 g
Automation Panel 1000 user's manual V2.00
5CASD3.
5CASD3.
5CASD3.
0300-00
0500-00
1000-00
Category 7 / Class F up to 600 MHz
per ISO/IEC 11801 (EN 50173-1),
ISO/IEC 24702 (EN 50173-3)
≥5 GΩ/km
-10 to 50°C
30 m
50 m
100 m
8.3 mm
≥4x diameter
≥8x diameter
2150 g
3500 g
6950 g
≤110 N
≤110 N