  • Page 1 Panel PC 2100 Panel mount devices User's manual Version: 2.02 (July 2024) Order no.: MAPPC2100-ENG Translation of the original documentation...
  • Page 2: Publishing Information

    Publishing information B&R Industrial Automation GmbH B&R Strasse 1 5142 Eggelsberg Austria Telephone: +43 7748 6586-0 Fax: +43 7748 6586-26 office@br-automation.com Disclaimer All information in this document is current as of its creation. The contents of this document are subject to change without notice.
  • Page 3: Table Of Contents

    4.1.4.2 +24 VDC power supply........................48 4.1.4.3 Ethernet interfaces..........................49 4.1.4.4 USB interfaces........................... 50 4.1.4.5 CFast slot............................51 4.1.4.6 Power and reset buttons........................51 4.1.4.7 LED status indicators.........................52 4.1.4.8 IF option slot(IF1, IFx)........................53 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 4 5.1 Basic information............................169 5.1.1 Installing a Panel PC with an AP9x3 panel..................171 5.1.2 Installing the Automation Panel 1000 with retaining clips..............173 5.1.3 Installing the Automation Panel 1000 with clamping blocks..............175 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 5 7.1.6.2 CPU configuration..........................202 7.1.6.3 Graphics (IGD) configuration......................204 7.1.6.4 LAN..............................206 7.1.6.5 PCI express configuration........................207 7.1.6.6 USB configuration..........................209 7.1.6.7 SATA configuration.......................... 210 7.1.6.8 Miscellaneous configuration......................210 7.1.6.9 Thermal configuration........................211 7.1.7 Security..............................213 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 6 7.2.1 BIOS upgrade............................220 7.2.1.1 Basic information..........................220 7.2.1.2 Procedure in the EFI shell....................... 221 7.2.2 Upgrading the firmware on the Panel PC 2100..................222 7.2.2.1 Procedure in Windows (ADI Control Center)...................222 7.2.2.2 Procedure in the EFI shell....................... 222 7.2.2.3 Firmware upgrade with Automation Runtime.................. 222 7.3 Multi-touch drivers............................223...
  • Page 7 8.2.2 Image persistence..........................251 8.2.2.1 What causes image persistence?....................251 8.2.2.2 How can image persistence be reduced?..................252 8.3 Information about display properties......................252 8.4 Replacing CFast cards..........................253 8.5 Repairs/Complaints and replacement parts....................253 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 8 A.D.2 Aluminum panel overlay........................280 A.D.3 Coated aluminum front......................... 280 A.D.4 Touch screen............................281 A.E Touch screen.............................. 282 A.E.1 5-wire touch screen (single-touch)....................... 282 A.E.1.1 Technical data..........................282 A.E.1.2 Temperature/Humidity diagram.......................282 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 9 A.H Installation compatibility..........................290 A.H.1 Compatibility overview.......................... 290 A.H.2 Compatibility details..........................292 A.H.2.1 Example............................292 A.H.2.2 5.7" devices.............................292 A.H.2.3 10.4" devices...........................294 A.H.2.4 12.1" devices...........................296 A.H.2.5 15" devices............................297 A.H.2.6 17" devices............................298 A.H.2.7 19" devices............................298 A.H.2.8 21.3" devices...........................299 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 10: Introduction

    Introduction 1 Introduction Information: B&R makes every effort to keep documents as current as possible. The most current versions are available for download on the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 11: Manual History

    9 "International and national certifications". • Documented configuration option for XHCI controller, see "USB configuration" on page 209. • Updated the following panels: ° "5AP1130.0702-000" on page 86 ° "5AP1130.101E-000" on page 92 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 12 Updated section "Touch screen" with "Touch screen (multi-touch generation 2)" "Touch screen (mul- ti-touch generation 3)". • Updated CFast card 5CFAST.256G-10, see "CFast cards" on page 168. Editorial changes are not listed. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 13: Information About This Document

    Up to 6 mm ±0.1 mm Over 6 to 30 mm ±0.2 mm Over 30 to 120 mm ±0.3 mm Over 120 to 400 mm ±0.5 mm Over 400 to 1000 mm ±0.8 mm Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 14: General Safety Guidelines

    Are protected by ESD-suitable packaging. 2.2.2 Regulations for proper ESD handling Electrical assemblies with housing • Do not touch the connector contacts of connected cables. • Do not touch the contact tips on circuit boards. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 15: Regulations And Measures

    • General safety regulations and national accident prevention regulations must be observed. • The electrical installation must be carried out in accordance with relevant regulations (e.g. line cross section, fuse protection, protective ground connection). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 16: Operation

    Internet poses a potential threat to the system. It is the direct responsibility of the user to avert these dangers and to take appropriate measures such as virus protection programs and firewalls to protect against them and to use only software from trustworthy sources. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 17: Cybersecurity Disclaimer For Products

    The term "control systems" refers to all types of B&R products such as controllers (e.g. X20), HMI systems (e.g. Power Panel T30), process control systems (e.g. APROL) and supporting systems such as engineering workstations with Automation Studio. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 18: System Overview

    System overview 3 System overview 3.1 About this user's manual This user's manual contains all relevant information about an operational Panel PC 2100 cabinet-mounted device. Information: All specifications in dimension diagrams and associated tables are in millimeters [mm]. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 19: Description Of Individual Modules

    PPC2100 devices in addition to interface option and CFast card connections. Main memory is permanently built into the system unit and cannot be replaced. If a system unit is installed on a panel, the result is an operational Panel PC 2100. Panel PC 2100 systems are mounted using retaining clips.
  • Page 20: Configuration

    System overview 3.3.1 Configuration The following individual components are required for operation as a Panel PC 2100: • Panel • System unit • CFast card for the operating system • Operating system Base system - Configuration Panels Select 1. Diagonal...
  • Page 21 Windows 10 1TG4600.10-5 5SWWI7.1200-ENG 1TG4601.06-5 5SWW10.0243-MUL 5SWWI7.1200-GER Automation Runtime 1TG4601.06-T 5SWW10.0543-MUL 5SWWI7.1400-MUL Windows Embedded Standard 7 5SWWI7.1543-ENG Linux for B&R 8 Linux for B&R 9 5SWWI7.1643-ENG 5SWLIN.0543-MUL 5SWLIN.0743-MUL 5SWWI7.1743-MUL 5SWLIN.0643-MUL 5SWWI7.1843-MUL Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 22: Order Number Key

    A current order number key is available on the B&R website for easy identification of the device con- figuration: Home > Downloads > Industrial PCs and Panels > Panel PC 2100 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 23: Overview

    5AP1130.185C-000 Automation Panel 18.5" Full HD TFT - 1920 x 1080 pixels (16:9) - Multi-touch (projected capacitive) - Control cabinet installation - Landscape format - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 24 (without Recovery DVD) - Only available with a new device 5SWWI7.1843-MUL Windows Embedded Standard 7 Premium SP1 - 64-bit - Service Pack 1 - Multilingual - PPC2100 - License (without Recovery DVD) - Only available with a new device Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 25: Technical Data

    258.5 105.5 245.5 13.5 18.5" multi-touch 5AP933.185B-00 166.5 13.5 21.5" multi-touch 5AP933.215C-00 541.5 528.5 199.75 13.5 24.0" multi-touch 5AP933.240C-00 598.5 585.5 228.25 System units Type Order number System unit 5PPC2100.BYxx-000 29.7 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 26 105.5 245.5 13.5 15.6" multi-touch 5AP1130.156C-000 258.5 105.5 245.5 13.5 15.6" multi-touch 5AP1130.156C-001 258.5 105.5 245.5 13.5 18.5" multi-touch 5AP1130.185C-000 166.5 13.5 System units Type Order number System unit 5PPC2100.BYxx-000 29.7 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 27 81.5 24.3 15.0" single-touch with keys 5AP1180.1505-000 81.5 24.3 15.0" single-touch with keys 5AP1181.1505-000 81.5 24.3 19.0" single-touch 5AP1120.1906-000 186.5 23.3 19.3 System units Type Order number System unit 5PPC2100.BYxx-000 29.7 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 28: Mounting Orientations

    4.1.1.2 Mounting orientations Information: When installing the Panel PC 2100, spacing for air circulation and additional free space for operating and servicing the device must be taken into account. All specifications in dimension diagrams and associated tables are in millimeters [mm].
  • Page 29 A 2.5 mm hex screwdriver is needed to tighten and remove the screw on the retaining clips. The maximum tightening torque of the retaining clips is 1 Nm. Information: A minimum circumferential distance of 30 mm must be maintained in order to enable installation with retaining clips. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 30 Dimension "Z" describes the thickness of the wall or control cabinet plate. A 3 mm hex screwdriver is needed to tighten or remove the screw on the clamping blocks. The maximum tightening torque of the clamping block is 0.5 Nm. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 31: Spacing For Air Circulation

    If the spacing specifications for air circulation cannot be observed, then the maximum specified tem- peratures for the temperature sensors (see "Temperature sensor positions" on page 41) must be monitored by the user and appropriate measures taken if they are exceeded. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 32: Mounting Orientations

    Technical data 4.1.1.4 Mounting orientations The following figures show the specified mounting orientations of Panel PC 2100 devices. A PPC2100 is only permitted to be installed as shown and described below. Inclination [°] Derating [°C] Inclination [°] Derating No limitation No limitation Up to ±90...
  • Page 33: Weight Specifications

    19.0" single-touch 5AP1120.1906-000 7300 System units and components Component Model number Weight [g] System units 5PPC2100.BYxx-000 5CFAST.xxxx-00 CFast cards 5CFAST.xxxx-10 5ACCIF01.FPCC-000 5ACCIF01.FPCS-000 5ACCIF01.FPLK-000 5ACCIF01.FPLS-000 5ACCIF01.FPLS-001 Interface options 5ACCIF01.FPSC-000 5ACCIF01.FPSC-001 5ACCIF01.FSS0-000 5ACCIF01.ICAN-000 5ACCIF01.IS00-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 34: Environmental Properties

    • Thermal Analysis Tool (TAT V4.3.4.13.01) from Intel for simulating a 100% processor load • BurnInTest tool (BurnInTest V7.0 Pro from PassMark Software) for simulating a 100% load on the interface using loopback adapters (USB interfaces) • Maximum system expansion and power consumption Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 35 ✓ ✓ 5ACCIF01.FPSC-000 5ACCIF01.FPSC-001 ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.FSS0-000 ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.ICAN-000 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.IS00-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 36 ✓ ✓ 5ACCIF01.FPSC-000 ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.FPSC-001 ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.FSS0-000 5ACCIF01.ICAN-000 ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.IS00-000 ✓ ✓ ✓ ✓ ✓ ✓ Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 37 ✓ ✓ 5ACCIF01.FPSC-000 5ACCIF01.FPSC-001 ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.FSS0-000 ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.ICAN-000 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 5ACCIF01.IS00-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 38 ° If the installed component has a temperature specification (e.g. "45[°C]"), the ambient temperature of the complete system is not permitted to exceed this value. 4. Possible limitations may arise due to the mounting orientation of the Panel PC 2100. For additional informa- tion, see section "Mounting orientations"...
  • Page 39 -20 to 60 5ACCIF01.FPSC-001 -20 to 60 -20 to 60 5ACCIF01.FSS0-000 -20 to 60 -20 to 60 5ACCIF01.ICAN-000 -20 to 60 -20 to 60 5ACCIF01.IS00-000 -20 to 60 -20 to 60 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 40: Temperature Monitoring

    Microsoft Windows or Linux for B&R operating systems. The temperature measured approximates the immediate ambient temperature but may also be influenced by neighboring components. Self-Monitoring, Analysis and Reporting Technology Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 41 Temperature of the processor area (sensor integrated on the CPU board) 95°C System unit sensor 1 Main memory Temperature of the main memory area (sensor integrated on the CPU board) 95°C Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 42: Humidity

    5 to 95 5ACCIF01.FSS0-000 5 to 90 5 to 95 5 to 95 5ACCIF01.ICAN-000 5 to 90 5 to 95 5 to 95 5ACCIF01.IS00-000 5 to 90 5 to 95 5 to 95 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 43: Vibration

    • Installation of all covers or components on interfaces and slots • Compliance with all ambient conditions The Panel PC 2100 with AP9x3 and AP1000 panels additionally has "Type 4X indoor use only" on the front per UL 50 under the same conditions.
  • Page 44: Electrical Properties

    Watchdog eDP2VLDS bridge Power-up sequencing Display connector Power 24 VDC input supply IF option Magnetics Magnetics Legend 2.0_Px USB 2.0 port x Internal interface 3.0_Px USB 3.0 port x External interface Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 45: Power Calculation

    4.1.3.2 Power calculation In order to calculate the total power of the Panel PC 2100, the power rating of the display used (see or ) must be added to the power rating of the system unit; if an interface option or optional CFast card is connected, these power ratings must be added as well.
  • Page 46: Cfast Cards

    12" panel 5AP923.1215-00 4.2 W + 7.2 W = 11.4 W 5PPC2100.BY11-000 system unit 23 W (with USB consumer) 23 W CFast card 5CFAST.064G-10 ≥ E0 1.1 W Total max.: 35.5 W Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 47: Device Interfaces And Slots

    "CFast slot" on page 51 "Grounding" on page 48 "USB interfaces" on page 50 "+24 VDC power supply" on page 48 Only available with installed interface option (configuration-dependent, see "Interface options" on page 132). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 48: Vdc Power Supply

    The wire cross section should be as large as possible (at least 2.5 mm²). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 49: Ethernet Interfaces

    A special driver is required to operate the Ethernet controller. Drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com). Information: Necessary drivers must be downloaded from the B&R website, not from manufacturer websites. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 50: Usb Interfaces

    USB 2.0 interface. For additional information, see section "USB interfaces" in chapter "Device interfaces and slots" on page USB hub interfaces 4-port USB hub 5ACCUSB4.0000-000 provides up to 4 additional USB interfaces for the Panel PC 2100. For additional information, see section "USB hub" on page 270.
  • Page 51: Cfast Slot

    Pressing the reset button triggers a hardware/PCI reset. The PC is restarted. During a reset, the MTCX processor is not reset. Warning! Switching off the power without shutting down or resetting the system can result in data loss! Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 52: Led Status Indicators

    Application in SERVICE mode Controlled by Automation Runtime (ARemb and AR- win). Orange Blinking A license violation has occurred. Two columns form 1 interval of 500 ms each. S5: Soft-off S4: Hibernate (suspend-to-disk) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 53: If Option Slot(If1, Ifx)

    Interface card - 1x CAN interface - For APC2100/ PPC2100 and APC2200/PPC2200 5ACCIF01.IS00-000 Interface card - 1x RS232 interface - For APC2100/ PPC2100/APC2200/PPC2200 Information: Interface options can only be installed and replaced at the B&R factory. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 54: Features Of Ap1000 Panels

    It is also possible to download a template for slide-in labels with individual captions from the B&R website (www.br-automation.com). The slots provided for slide-in labels are accessible on the rear of the Automation Panel devices. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 55: Key And Led Configuration

    • Hardware numbers of keys are specified in the follow- Operating element with LED ing with black indexes. • Hardware numbers of LEDs are specified in the follow- Key with LED ing with blue indexes. 5AP1151.0573-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 56 Technical data 5AP1180.1043-000 5AP1181.1043-000 5AP1182.1043-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 57 Technical data 5AP1180.1505-000 5AP1181.1505-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 58: Usb Interface

    Full speed (12 Mbit/s) High speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Cable length Max. 5 m (without hub) The USB interface is protected by a maintenance-free "USB current-limiting switch" (max. 500 mA). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 59: Individual Components

    Interface card - 1x CAN interface - For APC2100/PPC2100/ APC2200/PPC2200 - Only available with a new device 5ACCIF01.IS00-000 Interface card - 1x RS232 interface - For APC2100/PPC2100/ APC2200/PPC2200 - Only available with a new device Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 60 Max. dynamic graphics frequency 400 MHz 533 MHz 667 MHz 792 MHz Color depth Max. 32-bit DirectX support OpenGL support Power management ACPI 4.0 Interfaces CFast slot Quantity Type SATA II (SATA 3.0 Gbit/s) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 61 IEC 61010-2-201 requirements must be observed. Only if all interface covers are installed. The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 62: Ap9X3 Panels

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 63: Temperature/Humidity Diagram

    4.2.2.1.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 64: 5Ap923.1505-00

    Direction U = 70° / Direction D = 70° Backlight Type Brightness (dimmable) Typ. 20 to 400 cd/m² Half-brightness time 50,000 h Touch screen Technology Analog, resistive Controller B&R, serial, 12-bit Transmittance 81% ±3% Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 65 4.2.2.2.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 66: 5Ap923.1906-00

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 67 5AP923.1906-00 ≥ Rev. E0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 68 5AP923.1906-00 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 69: 5Ap933.156B-00

    At 25°C ambient temperature. Reducing the brightness by 50% can increase the half-brightness time by approximately 50%. The specifications of the touch screen driver must be taken into account; see section "Multi-touch driver". Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 70 5AP933.156B-00 ≤ Rev. C0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 71: 5Ap933.185B-00

    At 25°C ambient temperature. Reducing the brightness by 50% can increase the half-brightness time by approximately 50%. The specifications of the touch screen driver must be taken into account; see section "Multi-touch driver". Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 72 5AP933.185B-00 ≤ Rev. C0 RH [%] T [°C] -20 - 0 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 73: 5Ap933.215C-00

    At 25°C ambient temperature. Reducing the brightness by 50% can increase the half-brightness time by approximately 50%. The specifications of the touch screen driver must be taken into account; see section "Multi-touch driver". Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 74 5AP933.215C-00 ≤ Rev. C0 RH [%] T [°C] -20 - 0 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 75: 5Ap933.240C-00

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 76 5AP933.240C-00 ≥ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 77 5AP933.240C-00 ≤ Rev. C0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 78: Ap1000 Panels

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 79 5AP1120.0573-000 ≥ Rev. E0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 80 5AP1120.0573-000 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 81: 5Ap1151.0573-000

    Typ. 38 mcd Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 82 5AP1151.0573-000 ≥ Rev. E0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 83 5AP1151.0573-000 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 84: 5Ap1120.0702-000

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 85 4.2.3.3.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 86: 5Ap1130.0702-000

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 87 4.2.3.4.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 88: 5Ap1130.101D-000

    Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Mechanical properties Front Frame Aluminum, coated Design Black Gasket 3 mm fixed gasket Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 89 4.2.3.5.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 90: 5Ap1120.101E-000

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 91 4.2.3.6.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 92: 5Ap1130.101E-000

    Up to hardware revision H0: Typ. 25 to 500 cd/m² Half-brightness time 50,000 h Touch screen Technology Projected capacitive touch (PCT) Transmittance See "Appendix A - Touch screen". Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 93 4.2.3.7.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 94: 5Ap1120.1043-000

    Transmittance 81% ±3% Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 95 4.2.3.8.6 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 96: 5Ap1180.1043-000

    Transmittance 81% ±3% Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 97 10.4" AP1000 panels are supported starting with the following firmware versions: • Firmware V03.11 or later with SDL/DVI receiver 5DLSDL.1001-00 • Firmware V04.08 or later with SDL3 receiver 5DLSD3.1001-00 • Firmware V01.03 or later with PPC2100 system unit 5PPC2100.BYxx-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 98 4.2.3.9.6 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 99: 5Ap1181.1043-000

    Direction U = 80° / Direction D = 80° Backlight Type Brightness (dimmable) Typ. 22.5 to 450 cd/m² Half-brightness time 70,000 h Touch screen Technology Analog, resistive Controller B&R, serial, 12-bit Transmittance 81% ±3% Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 100 10.4" AP1000 panels are supported starting with the following firmware versions: • Firmware V03.11 or later with SDL/DVI receiver 5DLSDL.1001-00 • Firmware V04.08 or later with SDL3 receiver 5DLSD3.1001-00 • Firmware V01.03 or later with PPC2100 system unit 5PPC2100.BYxx-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 101 4.2.3.10.6 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 102: 5Ap1182.1043-000

    USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Keys Function keys 44 with LED (yellow) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 103 10.4" AP1000 panels are supported starting with the following firmware versions: • Firmware V03.11 or later with SDL/DVI receiver 5DLSDL.1001-00 • Firmware V04.08 or later with SDL3 receiver 5DLSD3.1001-00 • Firmware V01.03 or later with PPC2100 system unit 5PPC2100.BYxx-000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 104 4.2.3.11.6 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 105: 5Ap1120.1214-000

    Transmittance 81% ±3% Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 106 4.2.3.12.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 107: 5Ap1120.121E-000

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 108 4.2.3.13.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 109: 5Ap1130.121E-000

    Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Mechanical properties Front Frame Aluminum, coated Design Black Gasket 3 mm fixed gasket Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 110 4.2.3.14.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 111: 5Ap1130.121E-010

    Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Mechanical properties Front Frame Aluminum, coated Design Black Gasket 3 mm fixed gasket Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 112 4.2.3.15.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 113: 5Ap1120.1505-000

    Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 114 4.2.3.16.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 115: 5Ap1180.1505-000

    Transmittance 81% ±3% Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 116 4.2.3.17.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 117: 5Ap1181.1505-000

    Direction R = 80° / Direction L = 80° Vertical Direction U = 70° / Direction D = 70° Backlight Type Brightness (dimmable) Typ. 20 to 400 cd/m² Half-brightness time 50,000 h Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 118 Touch screen drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com). Visual deviations in color and surface quality are possible due to process or batch conditions. 4.2.3.18.4 Dimensions 4.2.3.18.5 Requirements 5AP1181.1505-000 is supported starting with the following firmware versions: Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 119 4.2.3.18.6 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 120: 5Ap1120.156B-000

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 121 Hardware revision H0 and later RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 122 Up to hardware revision G0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 123: 5Ap1130.156C-000

    Typ. 40 to 450 cd/m² Half-brightness time ≥50,000 h Touch screen Technology Projected capacitive touch (PCT) Transmittance See "Appendix A - Touch screen". Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 124 4.2.3.20.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 125: 5Ap1130.156C-001

    Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 126 4.2.3.21.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 127: 5Ap1130.185C-000

    See "Appendix A - Touch screen". Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 128 4.2.3.22.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 129: 5Ap1120.1906-000

    Direction R = 85° / Direction L = 85° Vertical Direction U = 85° / Direction D = 85° Backlight Type Brightness (dimmable) Typ. 35 to 350 cd/m² Half-brightness time 70,000 h Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 130 Touch screen drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com). Visual deviations in color and surface quality are possible due to process or batch conditions. 4.2.3.23.4 Dimensions Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 131 4.2.3.23.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 132: Interface Options

    Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck) ENV3 EC31B Temperature: 5 - 55°C Vibration: 0.7 g EMC: Bridge and open deck Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 133 The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the numbering used by the respective operating system, however. In Automation Studio / Automation Runtime, this interface is referred to as IF1. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 134: Cable Data

    2 interface. LED status indicator "L1" indicates whether IF option the terminating resistor of the CAN bus 1 interface is switched on or off. • ON: Switched on • OFF (default): Switched off Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 135 This interface can only be used in Automation Runtime and is displayed as IF2 in Automation Studio / Automation Runtime. It is not a "PC interface" and therefore not displayed in BIOS. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 136: Led Status Indicators

    The driver is part of the Automation Runtime and the firmware is part of Automation Studio. The module is auto- matically brought up to this level. To update the firmware contained in Automation Studio, a hardware upgrade must be performed (see Project management / Workspace / Upgrades in Automation Help). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 137: 5Accif01.Fpcs-000

    Remanent variables in power failure mode 32 kB (for e.g. Automation Runtime, see Automation Help) Interfaces Quantity Type RS485, not galvanically isolated Variant 10-pin, male UART 16550-compatible, 16-byte FIFO buffer Max. baud rate 115 kbit/s Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 138 The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the numbering used by the respective operating system, however. In Automation Studio / Automation Runtime, this interface is referred to as IF1. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 139 This interface can only be used in Automation Runtime and is displayed as IF3 in Automation Studio / Automation Runtime. It is not a "PC interface" and therefore not displayed in BIOS. CAN driver settings The baud rate can be set either with "predefined values" or via the "bit timing register". For additional information, see Automation Help. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 140 The driver is part of the Automation Runtime and the firmware is part of Automation Studio. The module is auto- matically brought up to this level. To update the firmware contained in Automation Studio, a hardware upgrade must be performed (see Project management / Workspace / Upgrades in Automation Help). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 141: 5Accif01.Fplk-000

    Class I, Division 2, Groups ABCD, T4 Controller nvSRAM Size 512 kB Data retention 20 years Read/Write endurance Min. 1,000,000 Battery-backed Remanent variables in power failure mode 256 kB (for e.g. Automation Runtime, see Automation Help) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 142 The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the numbering used by the respective operating system, however. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 143 The driver is part of the Automation Runtime and the firmware is part of Automation Studio. The module is auto- matically brought up to this level. To update the firmware contained in Automation Studio, a hardware upgrade must be performed (see Project management / Workspace / Upgrades in Automation Help). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 144: 5Accif01.Fpls-000

    32 kB (for e.g. Automation Runtime, see Automation Help) Interfaces Quantity Type RS232, modem supported, not galvanically isolated Variant 10-pin, male UART 16550-compatible, 16-byte FIFO buffer Max. baud rate 115 kbit/s Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 145 This interface (if available) is automatically enabled in BIOS as COMA with default addresses I/O:3F8h and IRQ:4. In Automation Studio / Automation Runtime, this interface is referred to as IF5. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 146 All interfaces of the interface option are supported in Automation Runtime / B&R Hypervisor. General purpose operating system (GPOS) If this interface option is used with a GPOS, only operation of the serial port(s) is supported and the firmware update function cannot be used. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 147: 5Accif01.Fpls-001

    256 kB (for e.g. Automation Runtime, see Automation Help) Interfaces Quantity Type RS232, modem supported, not galvanically isolated Variant 10-pin, male UART 16550-compatible, 16-byte FIFO buffer Max. baud rate 115 kbit/s Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 148 This interface (if available) is automatically enabled in BIOS as COMA with default addresses I/O:3F8h and IRQ:4. In Automation Studio / Automation Runtime, this interface is referred to as IF5. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 149 All interfaces of the interface option are supported in Automation Runtime / B&R Hypervisor. General purpose operating system (GPOS) If this interface option is used with a GPOS, only operation of the serial port(s) is supported and the firmware update function cannot be used. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 150: 5Accif01.Fpsc-000

    32 kB (for e.g. Automation Runtime, see Automation Help) Interfaces Quantity Type RS232, modem not supported, not galvanically isolated Variant 10-pin, male UART 16550-compatible, 16-byte FIFO buffer Max. baud rate 115 kbit/s Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 151 The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the numbering used by the respective operating system, however. In Automation Studio / Automation Runtime, this interface is referred to as IF1. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 152 Bit timing register 1 Baud rate 1000 kbit/s 80h or 00h 500 kbit/s 81h or 01h 250 kbit/s 83h or 03h 125 kbit/s 84h or 04h 100 kbit/s 89h or 09h 50 kbit/s Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 153: Terminating Resistor

    The driver is part of the Automation Runtime and the firmware is part of Automation Studio. The module is auto- matically brought up to this level. To update the firmware contained in Automation Studio, a hardware upgrade must be performed (see Project management / Workspace / Upgrades in Automation Help). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 154: 5Accif01.Fpsc-001

    256 kB (for e.g. Automation Runtime, see Automation Help) Interfaces Quantity Type RS232, modem not supported, not galvanically isolated Variant 10-pin, male UART 16550-compatible, 16-byte FIFO buffer Max. baud rate 115 kbit/s Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 155 The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the numbering used by the respective operating system, however. In Automation Studio / Automation Runtime, this interface is referred to as IF1. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 156 Bit timing register 1 Baud rate 1000 kbit/s 80h or 00h 500 kbit/s 81h or 01h 250 kbit/s 83h or 03h 125 kbit/s 84h or 04h 100 kbit/s 89h or 09h 50 kbit/s Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 157: Cable Data

    In addition, there is a functional ground connection on the interface cover of the system unit and a screw point for cable shields that can also be used for the shielded cables. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 158 The driver is part of the Automation Runtime and the firmware is part of Automation Studio. The module is auto- matically brought up to this level. To update the firmware contained in Automation Studio, a hardware upgrade must be performed (see Project management / Workspace / Upgrades in Automation Help). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 159: 5Accif01.Fss0-000

    Default setting Electrical properties Power consumption Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature Operation -20 to 60°C Storage -20 to 60°C Transport -20 to 60°C Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 160 The cable ends of an RS485 bus should be terminated (at least for longer cable lengths or higher transfer rates). Passive termination can normally be used by connecting the signal lines via a 120 Ω resistor at each of the two bus ends; see "Terminating resistor" for the IF card. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 161 The COM D terminating resistor is switched on. The COM D terminating resistor is switched off. Yellow The COM A terminating resistor is switched on. The COM A terminating resistor is switched off. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 162 • Automation PC 2100: V1.10 • Panel PC 2100: V1.10 The firmware can be downloaded from the B&R website (www.br-automation.com). For information about upgrading the firmware, see section "Upgrading the firmware on the Panel PC 2100" on page 222. 4.2.4.8.3.6 Hardware In order to ensure the functionality of the interface option, the PC must have at least the following hardware revision: •...
  • Page 163: 5Accif01.Ican-000

    Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight 25 g For detailed information, see the temperature tables in the user's manual. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 164 The LEDs of the interface option are located near the ETH1 interface. LED status indicator Color Status Explanation Yellow The CAN bus terminating resistor is switched The CAN bus terminating resistor is switched off. Not connected Not connected Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 165 • Automation PC 2100: V1.06 • Panel PC 2100: V1.06 The firmware can be downloaded from the B&R website (www.br-automation.com). For information about upgrading the firmware, see section "Upgrading the firmware on the Panel PC 2100" on page 222. 4.2.4.9.4 Shielding For the interfaces on the 10-pin female connector, the shield of the interfaces can be connected to pin Shield (pin 2) of the female connector.
  • Page 166: 5Accif01.Is00-000

    Storage -20 to 60°C Transport -20 to 60°C Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 25 g Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 167 (www.br-automation.com) (if required and not already included in the operating system). Approved operating systems: • Linux for B&R • Windows 10 • Windows Embedded 8.1 Industry • Windows 7 • Windows Embedded Standard 7 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 168: Cfast Cards

    Technical data 4.2.5 CFast cards Detailed information about compatible CFast cards is available on the B&R website (CFast cards). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 169: Installation And Wiring

    If the load-bearing capacity of the mounting surface is insufficient, or if the fastening material is inadequate or incorrect, the device may fall and become damaged. • To avoid overheating, the device is not permitted to be placed near other heat sources. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 170 If third-party devices or components are used, the relevant manufacturer's documentation must be observed. If lim- itations or interactions by or with third-party products are possible, this must be taken into account in the application. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 171: Installing A Panel Pc With An Ap9X3 Panel

    Installation and wiring 5.1.1 Installing a Panel PC with an AP9x3 panel The Panel PC 2100 with AP9x3 panel is installed in the installation cutout using retaining clips. The number of retaining clips depends on the panel. The device must be installed on a flat, clean and burr-free surface since tightening screws on an uneven area can result in damage to the display or the ingress of dust and water.
  • Page 172 4. Secure the retaining clips by alternately tightening the mounting screws with a 2.5 mm hex screwdriver (max. tightening torque 1 Nm). Thickness of the wall or control cabinet Minimum Maximum "Mounting orientations" on page 28 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 173: Installing The Automation Panel 1000 With Retaining Clips

    Installation and wiring 5.1.2 Installing the Automation Panel 1000 with retaining clips The Panel PC 2100 with AP1000 panel is installed in the installation cutout using retaining clips. The number of retaining clips depends on the panel. The device must be installed on a flat, clean and burr-free surface since tightening screws on an uneven area can result in damage to the display or the ingress of dust and water.
  • Page 174 4. Secure the retaining clips by alternately tightening the mounting screws with a 2.5 mm hex screwdriver (max. tightening torque 1 Nm). Thickness of the wall or control cabinet Minimum Maximum "Mounting orientations" on page 28 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 175: Installing The Automation Panel 1000 With Clamping Blocks

    Installation and wiring 5.1.3 Installing the Automation Panel 1000 with clamping blocks The Panel PC 2100 with AP1000 panel is installed in the installation cutout using clamping blocks. The number of clamping blocks depends on the panel. The device must be installed on a flat, clean and burr-free surface since tightening screws on an uneven area can result in damage to the display or the ingress of dust and water.
  • Page 176 0.5 Nm). The mounting screws push the clamping lever downwards, which in turn secures the device to the wall or control cabinet panel. Thickness of the wall or control cabinet Minimum Maximum "Mounting orientations" on page 28 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 177: Installation Information For Individual Components

    5.1.4 Installation information for individual components Information: If the Panel PC 2100 is not delivered as a complete system but as individual components (or individual components are installed afterward), then these components must be enabled in BIOS. This is done by launching BIOS when booting the system, loading the default BIOS values and then saving the set- tings.
  • Page 178: Replacing The System Unit

    7. The system unit can now be replaced by following these steps in reverse order. The maximum tightening torque of the Torx screws (T10) is 0.5 Nm. Only the mounting materials included in delivery are permitted to be used to install the system unit. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 179: Installing The Usb Hub

    The entire power supply to the B&R industrial PC or B&R Automation Panel must be interrupted. Before connecting the DC power cable, it must be checked whether it has been disconnected from the voltage source (e.g. power supply unit). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 180: Wiring

    • Functional ground connection of the power supply • Ground connection The functional ground on the B&R device is marked with the following symbol: The following points must be observed to ensure that electrical interference is safely diverted: Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 181 Legend Power supply connection +24 VDC pin 2 Central grounding point Ground connection At least 1.5 mm² At least 2.5 mm² Legend Central grounding point Ground connection At least 2.5 mm² Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 182: Connecting Cables

    When connecting or installing cables, the bend radius specification must be observed. For this specification, see the technical data of the respective cable. The maximum tightening torque of the locating screws is 0.5 Nm. Bend radius Locating screws Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 183: Commissioning

    • A USB keyboard and USB mouse are connected (optional). 6.2.2 Switching on the device Procedure 1. Connect the power supply and switch it on (e.g. power supply unit). 2. The device is operating and boots; LED Power lights up. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 184: General Instructions About The Procedure For Temperature Testing

    The ADI Control Center can be downloaded from the B&R website (www.br-automation.com) at no cost and uses the ADI (Automation Device Interface). If historical recording of the data is necessary, a separate application can be created. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 185: Evaluating With The Burnintest Tool From Passmark

    Loopback adapters are also available from PassMark. For additional information, see www.pass- mark.com. The following screenshots refer to PassMark BurnInTest Pro V7.1 using a PPC2100 without IF options. Overview of settings: Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 186 Option USB must be deselected under Test selection and duty cycles, and Test this device must then be selected in the Disk settings (Configuration / Test Preferences / Disk). Serial loopback adapters can be easily created by connecting some pins as shown. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 187: Evaluating Temperatures In Other Operating Systems

    The appropriate driver is available for download in the Downloads section of the B&R website (www.br-automation.com). 6.4.1.5 Windows Embedded Standard 7 Embedded / Premium A touch screen driver will be installed automatically if a touch controller is detected during the Windows Embedded Standard 7 installation. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 188: Multi-Touch (Projected Capacitive - Pct)

    BIOS Setup, i.e. the value set in BIOS is used until Windows boots. The value set in BIOS is only applied the first time the ADI Control Center is launched. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 189: Known Problems / Characteristics

    Projects in Automation Studio must be updated with the following HWX upgrades or higher: Order number Order number Order number 5PPC2100.BY01-000 V1.4.2.0 5PPC2100.BY22-000 V2.1.2.0 5PPC2100.BY44-000 V2.1.2.0 5PPC2100.BY11-000 V1.4.2.0 5PPC2100.BY34-000 V2.1.2.0 5PPC2100.BY48-000 V2.1.2.0 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 190: Software

    To enter BIOS Setup, the "F2" key must be pressed after the USB controller has been initialized as soon as the following message appears on the monitor (during POST): "F2 = Setup" 7.1.3 BIOS default settings Setting options marked in bold represent the default value. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 191: Bios Setup Buttons

    Jumps to the first BIOS menu option or object. Jumps to the last BIOS menu option or object. Resets the changes. Loads and sets CMOS default values for all BIOS settings. Saves and closes. Exits the submenu. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 192: Main

    Displays the date the BIOS was created. None Processor type Displays the processor type. None Processor speed Displays the processor frequency. None System memory speed Displays the main memory frequency. None Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 193 Displays the L2 cache size. None Total memory Displays the total main memory size. None Displays the main memory size in slot 1. None Displays the main memory size in slot 2. None Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 194: Advanced

    210. Miscellaneous configura- Configures various settings. Enter Opens this submenu tion "Miscellaneous configuration" on page 210. Thermal configuration Configures the temperature settings. Enter Opens this submenu "Thermal configuration" on page 211. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 195: Oem Features

    Enter Opens this submenu play. "Display board features" on page 199. IF board features Displays device-specific information for the IF Enter Opens this submenu option. "IF board features" on page 201. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 196: Super Io Configuration

    Manual settings for "Base address" and "IRQ" are possible. Default Default settings are used. Base address Sets or displays the I/O address. 2F8h Default setting Any I/O address can be entered. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 197: System Board Features

    B&R via the ADI driver. Statistical values Displays the statistical values. Enter Opens this submenu "Statistical values" on page 198. Temperature Values Displays current temperature values. Enter Opens this submenu "Temperature values" on page 198. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 198: Temperature Values

    (system unit sensor 2) in °C and °F (sensor close to the RAM). Sensor 2 Displays the current temperature of sensor 2 None (system unit sensor 1) in °C and °F (sensor near the CPU). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 199 Displays current temperature values. Enter Opens this submenu "Temperature values" on page 200. Panel #15 Displays the panel properties of the panel. Enter Opens this submenu "Panel #15" on page 200. 7.1.6.1.4.1 Statistical values Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 200 Displays the fan speed of the panel. None Keys/LEDs Displays the available keys and LEDs for the None panel. Temperature Displays the temperature of the panel in °C and None °F. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 201 BIOS setting Explanation Configuration options Effect Total hours Displays the runtime in hours. None Power on cycles Displays the power on cycles - Each restart in- None creases the counter by one. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 202: Cpu Configuration

    Displays whether Intel Hyper-Threading Tech- None Technology nology is supported. CPU power management Configures CPU energy settings. Enter Opens this submenu "CPU power management" on page 203. PROCHOT = Processor Hot Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 203: Cpu Power Management

    0 V. Maximum C state C1. The processor is in sleep mode. Switch between C0 and C1. This setting is only possible if C-states is set to Enabled. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 204: Graphics (Igd) Configuration

    Disables this function. ics controller. Enabled Enables this function. IGD - LCD control Configures the display settings of the PPC2100. Enter Opens this submenu "IGD - LCD control" on page 205. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 205: Igd - Lcd Control

    For example, a dual DVI display configuration is automatically restored when both DVI monitors are reconnected, even if only one DVI monitor was connected and activated during a previous boot procedure. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 206: Lan

    Enabled Enables this function. The Ethernet controller can switch on the system. Network stack Configures the network stack Enter Opens submenu "Network stack" on page 207 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 207: Network Stack

    Option for enabling/disabling IPv4 PXE support. Enables this function. Disabled Disables this function. IPv6 Option for enabling/disabling IPv6 PXE support. Enabled Enables this function. Disabled Disables this function. 7.1.6.5 PCI express configuration Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 208 Automatic assignment by BIOS and the operat- ing system. Assign INT to root port Option for enabling/disabling the IRQ for the Enabled Enables this function. root port. Disabled Disables this function. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 209: Usb Configuration

    The USB port is enabled. USB port #3 Option for enabling/disabling the multi-touch or Disabled The USB port is disabled. the optional front USB interface. Enabled The USB port is enabled. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 210: Sata Configuration

    Phoenix SecureCore Technology Setup Main Advanced Miscellaneous Configuration Item Specific Help Realtime Environment Disabled Enable or Disable the High Prescision Event Timer Hypervisor Environment Disabled PCI MMIO Size [Auto] Extended Temperature Range [Disabled] Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 211: Thermal Configuration

    This is not the case with 64-bit operat- ing systems. Extended temperature Option for setting the RAM refresh rate for ex- Disabled Default RAM refresh rate. range tended temperature. Enabled Increases the RAM refresh rate. 7.1.6.9 Thermal configuration Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 212 55°C / 131°F, 63°C / 145°F, 71°C / 160°F, 79°C / 174°F, 85°C / 185°F, 87°C / 189°F, 90°C / 194°F, 95°C / 203°F, 103°C / 217°F Disabled Disables this function. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 213: Security

    Enabled The user password must be entered for each boot procedure. The setting can only be set if a supervisor password is assigned. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 214: Boot

    ´Del´ 6. USBHDD P2: deletes an unprotected 7. USBHDD P3: device. 8. ATAPI CD: 9. SATA HDD1: 10. PCI LAN0: 11. PCI LAN1: 12. Watchdog 13. Internal Shell Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 215: Boot Configuration

    Enables this function. USB legacy support Option for setting the USB legacy support. Disabled Disables this function. The complete USB support is disabled (mouse, keyboard, USB mass storage, etc.). Enabled Enables this function. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 216 (approx. 130 MB more) is reserved. This setting is only possible if Console redirection is set to Enabled. This setting is only possible if Legacy boot is set to Enabled. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 217: Exit

    (provided they have not yet been saved). Save changes Selecting this option saves any changes made Yes/No to CMOS after confirmation. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 218: Allocation Of Resources

    Advanced Configuration and Power Interface Resistive onboard touchscreen for Panel PC 2100 Monitor/Panel option, SDL/DVI transmitter, SDL3 transmitter 5ACCIF01.FPLS-000 IF option, 5ACCIF01.FPLS-001, COM A. IF option ● ... Default setting ○ ... Optional setting Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 219: Interrupt Assignments In Apic Mode

    PIRQ D PCIe 3 SATA ETH1 APIC IRQ 19 PIRQ E XHCI APIC IRQ 20 PIRQ F APIC IRQ 21 PIRQ G APIC IRQ 22 PIRQ H USB EHCI APIC IRQ 23 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 220: Upgrade Information

    This information is listed on the following BIOS Setup page. • After switching on the PC, press "F2" to access BIOS Setup. • Select "OEM features" from BIOS main menu "Advanced". System BIOS MTCX firmware Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 221: Procedure In The Efi Shell

    5. After a successful upgrade, the system must be rebooted. 6. Reboot and press key "F2" to enter BIOS Setup and load the setup defaults; then select "Save changes and exit". Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 222: Upgrading The Firmware On The Panel Pc 2100

    Software 7.2.2 Upgrading the firmware on the Panel PC 2100 With "Firmware upgrade (MTCX)", it is possible to update the firmware depending on the version of the PPC2100 system. A current firmware upgrade can be downloaded directly from the Downloads section of the B&R website (www.br-...
  • Page 223: Multi-Touch Drivers

    • Linux for B&R 9 • Linux for B&R 8 No guarantee can be given for multi-touch or single-touch operation, compatibility and functionality for operation with other operating systems and/or individual touch screen drivers. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 224: Windows 10 Iot Enterprise 2016 Ltsb

    Configurable (disabled by default in the image by the UWF) Defragmentation service ✓ (Disabled when enabling the UWF) Additional embedded lockdown functions Assigned access Configurable AppLocker Configurable Shell Launcher Configurable ✓ Unified Write Filter Keyboard Filter Configurable Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 225: Installation

    • Unlike standard Windows 10 Enterprise, Windows 10 IoT Enterprise 2016 LTSB does not include Cortana, the Microsoft Edge browser or the Microsoft Store, for example. • The LTSB version is based on build 14393 of Windows 10 and does not receive any feature updates. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 226: Supported Display Resolutions

    Per Microsoft requirements, Windows 10 IoT Enterprise 2016 LTSB requires SVGA resolution (800 x 600) or higher to enable full operation of the Windows user interface (including system dialog boxes, apps, etc.). A lower resolution can be selected for applications. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 227: Windows 10 Iot Enterprise 2015 Ltsb

    Configurable (disabled by default in the image by the UWF) Fast boot Configurable (disabled by default in the image by the UWF) Defragmentation service Configurable (disabled by default in the image by the UWF) Additional embedded lockdown functions Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 228: Installation

    Windows 10 IoT Enterprise 2015 LTSB does not carry out any restarts or show any pop-up messages, which means that it is fully functional at all times. "Personalization" is not possible, however (e.g. setting the desktop background image). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 229: Content Of Delivery Of The Recovery Dvd

    Per Microsoft requirements, Windows 10 IoT Enterprise 2015 LTSB requires SVGA resolution (800 x 600) or higher to enable full operation of the Windows user interface (including system dialog boxes, apps, etc.). A lower resolution can be selected for applications. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 230: Windows Embedded 8.1 Industry Pro

    Configurable (disabled by default in the image by the UWF) Defragmentation service Configurable (disabled by default in the image by the UWF) Additional embedded lockdown functions Assigned access Configurable Dialog box filter Configurable Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 231: Installation

    Activation may be lost if the hardware is changed (e.g. if components are replaced in case of repair) or if the system is reinstalled (e.g. with the recovery DVD). In this case, a "watermark message" will always be shown on the screen: Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 232: Content Of Delivery Of The Recovery Dvd

    Per Microsoft requirements, Windows Embedded 8.1 Industry Pro requires XGA resolution (1024 x 768) or higher to enable full operation of the Windows user interface (including system dialog boxes, apps, etc.). A lower resolution can be selected for applications. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 233: Windows 7

    The memory space required by additional language packs is not taken into account in the minimum size for the data storage medium. 7.7.4 Installation Windows 7 is preinstalled by B&R on the desired data storage medium (e.g. CFast card). All necessary drivers (graphics, network, etc.) for operation are also installed. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 234: Drivers

    Per Microsoft requirements, Windows 7 requires XGA resolution (1024 x 768) or higher to enable full operation of the Windows user interface (including system dialog boxes, etc.). A lower resolution can be selected for appli- cations. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 235: Windows Embedded Standard 7

    The memory space required by additional language packs is not taken into account in the minimum size for the data storage medium. 7.8.4 Features The feature list shows the most important device functions in Windows Embedded Standard 7. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 236: Installation

    Per Microsoft requirements, Windows Embedded Standard 7 requires XGA resolution (1024 x 768) or higher to enable full operation of the Windows user interface (including system dialog boxes, etc.). A lower resolution can be selected for applications. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 237: Automation Runtime

    • ARwin upgrade AR N4.10 for 5PPC2100.BY48-000 • Automation Studio V4.1.4.0 • Technology Guard Information: In order to operate Automation Runtime Windows (ARwin), BIOS setting Advanced - Miscellaneous configuration - Realtime environment must be set to Enabled. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 238: Automation Runtime Embedded (Aremb)

    Automation Runtime V4.08. A Technology Guard is not necessary in earlier Automation Runtime versions. For additional information about Technology Guarding, see Automation Help. For BIOS versions 1.40 and later: RC6 (render standby) is automatically disabled when Realtime environment is enabled. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 239: B&R Hypervisor

    Windows version, B&R Hypervisor is completely independent of the version of the operating systems used. System requirements The following minimum software versions are required to operate B&R Hypervisor on the Panel PC 2100 : • ARemb upgrade AR F4.44 •...
  • Page 240: Mapp Technology

    Complex algorithms are easy to master. The programmer can concentrate fully on the machine process. Information: For detailed information, see Automation Help or the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 241: Linux For B&R 8 (Gnu/Linux)

    • HMI diagnostics tool • Tool for right-click support via touch screen • Virtual keyboard Detailed instructions about Linux for B&R 8 can be downloaded from the Downloads section of the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 242: Installation

    Installation packages are available for the necessary B&R adjustments; these can also be downloaded from the B&R website (www.br-automation.com). 7.12.6 Drivers The operating system contains all drivers necessary for operation. The current version of B&R-specific drivers can be downloaded and installed from the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 243: Linux For B&R 9 (Gnu/Linux)

    Detailed instructions about Linux for B&R 9 can be downloaded from the Downloads section of the B&R website (www.br-automation.com). 7.13.5 Installation Linux for B&R 9 is preinstalled on the desired data storage medium (e.g. CFast card). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 244: Drivers

    Current drivers for all approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com). Information: Necessary drivers must be downloaded from the B&R website, not from manufacturer websites. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 245: Adi Control Center

    The ADI driver (also includes the ADI Control Center) and user documentation can be downloaded at no cost from the Downloads section of the B&R website (www.br-automation.com). If a more recent version is available, it can be installed later. Information: The Write filter must be disabled during installation. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 246: Adi Development Kit

    For a detailed description of how to use ADI functions, see Automation Help. The ADI Development Kit can be downloaded at no cost from the Downloads section of the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 247: Adi .Net Sdk

    For a detailed description of how to use ADI functions, see Automation Help. The ADI .NET SDK can be downloaded at no cost from the Downloads section of the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 248: Key Editor

    For detailed instructions about configuring keys and LEDs and installing the key configuration on the target system, see the help documentation for the Key Editor. The Key Editor and help documentation can be downloaded at no cost from the Downloads section of the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 249: Kcf Editor

    For detailed instructions about configuring keys and LEDs and installing the key configuration on the target system, see the user documentation for the KCF Editor. The KCF Editor and user documentation can be downloaded at no cost from the Downloads section of the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 250: Hmi Service Center

    HMI Service Center USB flash drive - Hardware diagnostic soft- ware - For APC910/PPC900 - For PPC1200 - For APC2100/ PPC2100 - For APC2200/PPC2200 - For APC3100/PPC3100 - For APC mobile - For AP800/AP900 - For AP9x3/AP9xD - For AP1000/AP5000 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 251: Maintenance

    • Line type: This can result in permanent damage. 8.2.2.1 What causes image persistence? • Static images • No screensaver • Sharp transitions in contrast (e.g. black/white) • High ambient temperatures • Operation outside of specifications Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 252: How Can Image Persistence Be Reduced

    Displays can display colors or color ranges differently due to the manufacturing process, the properties of the components used, environmental influences and aging. This cannot be completely ruled out even with two similar devices of the same revision. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 253: Replacing Cfast Cards

    Repairs are therefore only permitted to be carried out by authorized qualified personnel at the manufacturer's premises. To process a repair/complaint, a repair order or complaint must be created via the B&R Material Return Portal on the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 254: International And National Certifications

    Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission stan- dard for industrial environments Information: Declarations of conformity are available on the B&R website under Downloads > Certificates > Decla- rations of conformity. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 255: Certifications

    Products with this marking are permitted to be imported into Great Britain (England, Wales, Scotland). Information: Declarations of conformity are available on the B&R website under Down- loads > Certificates > Declarations of conformity. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 256: Rcm

    Korean Register of Shipping (KR). Certificates with specifications for permissible environmental conditions are avail- able on the B&R website (Downloads > Certificates > Maritime). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 257: Certifications For Use In Potentially Explosive Environments

    Risk of explosion: Accessories are not permitted to be connected or disconnected when the power is switched on unless the area is considered nonhazardous and is free of ignitable concentrations! Risk of explosion: Replacing components may impair eligibility for Class I, Division 2! Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 258 Danger! Failure to follow this instruction can result in death, serious bodily injury or damage to property! Danger ! Le non-respect de ces instructions peut entraîner des blessures graves ou mortelles! Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 259: Explosion Hazard

    Interface USB1 (USB 3.0): No-load voltage [V 5.13 V Short circuit current [I 2060 mA Associated capacitance [C 20 μF Associated inductance [L 4.8 μH Table 101: Nonincendive circuit parameters for interface USB1 Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 260 The B&R device is suitable for use in Class I, Division 2, Groups A, B, C and D areas. It also provides nonincendive field wiring for devices in Class I, Division 2, Groups A, B, C and D. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 261: Risk Of Explosion

    ) for the nonincendive device, the permissible values of C ) and L ) for the connected device must be greater than or equal to C and L Cable Cable for the nonincendive device with field wiring. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 262 The B&R device is suitable for use in Class I, Division 2, Groups A, B, C and D areas. It also provides nonincendive field wiring for devices in Class I, Division 2, Groups A, B, C and D. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 263 ) for the nonincendive device, the permissible values of C ) and L ) for the connected device must be greater than or equal to C and L Cable Cable for the nonincendive device with field wiring. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 264 The B&R device is suitable for use in Class I, Division 2, Groups A, B, C and D areas. It also provides nonincendive field wiring for devices in Class I, Division 2, Groups A, B, C and D. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 265: Accessories

    The following accessories can be ordered for the Automation PC, Panel PC link modules and converters: • Grounding clip 10.1.1 Accessories - Order data Material number Description 5ACCRHMI.0000-000 REP HMI grounding clip Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 266: Installation Accessories

    2.0 Nm - 1x hex head bit 2.5, length 89 mm - 1x hex head bit 3.0, length 89 mm - 1x hex head bit 5.0, length 89 mm - 1x Torx 10 bit, length 90 mm - 1x Torx 20 bit, length 89 mm Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 267: Terminal Block Power Supply

    Pollution degree per EN 61131-2 Pollution degree 2 The cage clamp terminal block cannot be used side by side. The respective limit data of the I/O modules must be taken into account! Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 268: Terminal Block For If Options

    Nominal voltage 300 V Nominal current 10 A Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 The respective limit data of the I/O modules must be taken into account! Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 269: Usb Mass Storage Device

    Accessories 10.5 USB mass storage device For additional information about compatible USB mass storage devices, see the B&R website (USB mass storage devices). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 270: Usb Hub

    Total max. 1 A (sum of all 4 ports) Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Back: IP20 (front: depends on the panel used) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 271: Usb Interfaces

    The USB hub is protected by a maintenance-free "USB current-limiting switch" (max. 1 A). Information: If a Technology Guard (USB dongle) is used, it is recommended to connect it to the USB HUB 3 inter- face. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 272: Dimensions

    Accessories 10.6.1.4 Dimensions 47.5 10.7 Cables For additional information about compatible cables, see the B&R website (HMI cable manual). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 273: Replacement Parts

    10.8.1 Replacement parts - Order data Material number Description 5ACCRPC2.0000-000 PPC2100/2200 mounting screws kit - 4x screw M3x34 mm - 2x special screw for PPC2100 5ACCRPC2.0001-000 xPC2100/2200 interface covers - 1x cover set Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 274: Environmentally Friendly Disposal

    Operating and monitoring devices Uninterruptible power supplies Batteries and rechargeable batteries Cables Paper/Cardboard packaging Paper/Cardboard recycling Plastic packaging material Plastic recycling Disposal must be carried out in accordance with applicable legal regulations. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 275: Abbreviations

    Discrete level specifying the ability of safety-related devices to perform a safety function under foreseeable conditions. Probability of failure per hour Probability of a failure per hour. Safety integrity level Safety integrity level Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 276: Maintenance Controller Extended (Mtcx)

    . The version can be read in BIOS or in approved Microsoft Windows operating systems using the B&R Control Center. Can be downloaded from the Downloads section of the B&R website (www.br-automation.com). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 277: Viewing Angles

    Appendix A A.C Viewing angles For viewing angle specifications (R, L, U, D) of the display types, see the technical data of the individual compo- nents. 6 o'clock direction Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 278: Chemical Resistance

    • AP9x3 single-touch panels < revision B8 were manufactured with an aluminum panel overlay. Touch screen Panel overlay Multi-touch panels • AP9x3 and AP1000 multi-touch panels are equipped with a continuous glass surface. Touch screen Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 279: A.d.1 Autotex Panel Overlay (Polyester)

    • Xylene • Sodium bisulphate • Dibutyl phthalate Per DIN 42115 Part 2, the panel overlay is resistant to exposure to glacial acetic acid for less than one hour without visible damage. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 280: A.d.2 Aluminum Panel Overlay

    • Sidolin • Diesel • Sodium hydroxide <40% • Skydrol • Acetic acid <50% • Petroleum The coated aluminum front is not resistant to the following chemicals: • Acetone • Ethyl acetate Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 281: A.d.4 Touch Screen

    • Water • Hydrogen chloride <6% • Methylbenzene • White wine vinegar • Coca-Cola • Methyl ethyl ketone • Windex Original • Dimethylbenzene • Naphtha • Ethanol • Nitric acid <70% Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 282: Touch Screen

    90% RH at max. 60°C for 504 hours A.E.1.2 Temperature/Humidity diagram Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 283: A.e.2 Touch Screen (Multi-Touch Generation 2)

    A.E.2.3 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 284: A.e.3 Touch Screen (Multi-Touch Generation 3)

    A.E.3.3 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 285: Cable Data

    Pair shielding with aluminum foil Cable cross section 1x 0.34 mm² (22AWG/19), tinned copper stranded wire Wire insulation Conductor resistance ≤59 Ω/km Outer jacket Material PUR compound Properties Halogen-free Cable shield Tinned copper wire Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 286: A.f.3 Rs485 - Bus Length And Cable Type

    Pair shielding with aluminum foil Cable cross section 1x 0.34 mm² (22AWG/19), tinned copper stranded wire Wire insulation Conductor resistance ≤59 Ω/km Outer jacket Material PUR compound Properties Halogen-free Cable shield Tinned copper wire Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 287: Powerlink

    This mode can only be exited by resetting the controller. Controlled node (CN) If POWERLINK communication is detected during this mode, the interface enters mode PRE_OPERATIONAL_1. Table: LED "S/E" - Interface state (interface in POWERLINK mode) Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 288 MN. Table: LED "S/E" - Interface state (interface in POWERLINK mode) Blink times Triple flash 1000 Double flash 1000 Single flash 1000 Blinking Flickering All times in ms Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 289: A.g.1.3 System Stop Error Codes

    240. If the POWERLINK node is operated as a controlled node (CN), a node number from 1 to 239 can be set in the POWERLINK configuration in Automation Studio. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 290: Installation Compatibility

    323 x 358 sions Por- trait1 Installation 303 x 336 303 x 341 dimensions Outer dimen- 362 x 284 sions Land- 12.1" scape1 Installation 345 x 267 342 x 267 dimensions Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 291 583 x 464 mensions Land- 21.3" scape1 Installation 566 x 447 dimensions Device designation "AP1000" refers to the Automation Panel 1000 as well as to Panel PCs installed on AP1000 panels. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 292: A.h.2 Compatibility Details

    PP100/200/300/400 289 x 174 PP500 Outer contour of device Cutout for device The 5.7" Power Panel 500, Power Panel 300/400 and Power Panel 100/200 devices in Landscape2 format are 100% compatible. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 293 If this is not the case, the retaining clips can no longer grip and impermeability is no longer ensured by the circumferential cord gasket (IP65). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 294: A.h.2.3 10.4" Devices

    If this is not the case, the retaining clips can no longer grip and impermeability is no longer ensured by the circumferential cord gasket (IP65). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 295 If this is not the case, the retaining clips can no longer grip and impermeability is no longer ensured by the circumferential cord gasket (IP65). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 296: A.h.2.4 12.1" Devices

    The larger cutout can be used conditionally for all devices: • During installation, it is important to ensure that the AP1000, AP900, PPC700 and PP500 devices are positioned and installed as centrally as possible in the cutout. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 297: A.h.2.5 15" Devices

    If this is not the case, the retaining clips can no longer grip and impermeability is no longer ensured by the circumferential cord gasket (IP65). Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 298: A.h.2.6 17" Devices

    510 x 404 PPC800 Outer contour of device Cutout for device The 19" Automation Panel 1000, Automation Panel 900, Panel PC 700 and Panel PC 800 in Landscape1 format are 100% compatible. Panel PC 2100 Panel mount devices User's manual V2.02...
  • Page 299: A.h.2.8 21.3" Devices

    The cutout tolerance for the AP1000 is +0 mm / -0.5 mm. Installation compatibility - 21.3" devices - Landscape1 583 x 464 566 x 447 AP900 Outer contour of device Cutout for device Panel PC 2100 Panel mount devices User's manual V2.02...