Publishing information B&R Industrial Automation GmbH B&R Strasse 1 5142 Eggelsberg Austria Telephone: +43 7748 6586-0 Fax: +43 7748 6586-26 office@br-automation.com Disclaimer All information in this document is current as of its creation. The contents of this document are subject to change without notice.
Table of contents 1 Introduction......................10 1.1 Manual history...............................10 1.2 Information about this document........................10 1.2.1 Organization of notices..........................10 1.2.2 Guidelines..............................10 2 General safety guidelines..................11 2.1 Intended use..............................11 2.2 Protection against electrostatic discharge....................11 2.2.1 Packaging..............................11 2.2.2 Regulations for proper ESD handling..................... 11 2.3 Regulations and measures...........................
Page 4
Table of contents 4.1.5.9 LED status indicators.........................58 4.1.5.10 Power button / Reset button......................59 4.1.5.11 Battery.............................. 60 4.1.5.12 Slide-in compact slot........................61 4.1.5.13 Slide-in slot............................61 4.1.5.14 Main memory slots...........................62 4.1.5.15 IF options............................63 4.1.5.16 Card slot (PCI / PCIe)........................64 4.1.6 Layout of AP1000 display units......................65 4.1.6.1 Slide-in labels.............................65 4.1.6.2 Key and LED configuration........................66 4.1.6.3 USB interface.............................
Introduction 1 Introduction Information: B&R makes every effort to keep documents as current as possible. The most current versions are available for download on the B&R website (www.br-automation.com). 1.1 Manual history Version Date Change 1.10 September 2022 Updated the following chapters: •...
General safety guidelines 2 General safety guidelines 2.1 Intended use In all cases, it is necessary to observe and comply with applicable national and international standards, regulations and safety measures! The B&R products described in this manual are intended for use in industry and industrial applications. The intended use includes control, operation, monitoring, drive and HMI tasks as part of automation processes in machines and systems.
General safety guidelines • Measuring instruments and devices must be grounded. • Test probes of floating potential measuring instruments must be discharged briefly on suitable grounded surfaces before measurement. Individual components • ESD protective measures for individual components are implemented throughout B&R (conductive floors, shoes, wrist straps, etc.).
General safety guidelines 2.6.2 Ambient conditions - Dust, moisture, aggressive gases The use of operating and monitoring devices (e.g. industrial PCs, Power Panels, Mobile Panels) and uninterruptible power supplies in dusty environments must be avoided. This can otherwise result in dust deposits that affect the functionality of the device, especially in systems with active cooling (fans), which may no longer ensure sufficient cooling.
System overview 3 System overview 3.1 Description of individual modules 3.1.1 AP9x3 panels AP9x3 panels form the basis for the Automation Panel 9x3, Panel PC 900, Panel PC 2100, Panel PC 2200 and Panel PC 3100 system families. They consist of a display and touch screen. Different display diagonals and touch screen technologies are available.
System overview 3.2 Design/Configuration Automation Panel 9x3, Automation Panel 1000, Panel PC 900, Panel PC 2100, Panel PC 2200 and Panel PC 3100 systems can be assembled to meet individual requirements and operating conditions. Automation Panel 9x3, Panel PC 900, Panel PC 2100, Panel PC 2200 and Panel PC 3100 systems are flexible so that an Automation Panel can be converted to a Panel PC or vice versa.
System overview 3.2.1 Base system - Configuration Panel PC 900 systems can be operated with or without a fan kit. This choice plays a role in determining the type of housing to be used. Using a fan kit allows for operation at higher ambient temperatures. For additional information, see section "Maxi- mum ambient temperature for worst-case operation"...
System overview 3.2.3 Configuration options Panel PC 900 without bus unit: Panel PC 900 Panel PC 900 with power supply Figure 1: Panel PC 900 without bus unit Panel PC 900 with 1-slot bus unit: Panel PC 900 with 1-slot bus unit Panel PC 900 with 1-slot bus unit and power supply Figure 2: Panel PC 900 with 1-slot bus unit Panel PC 900 (Skylake) User's manual V 1.10...
Page 19
System overview Panel PC 900 with 2-slot bus unit: Panel PC 900 with 2-slot bus unit Panel PC 900 with 2-slot bus unit and power supply Figure 3: Panel PC 900 with 2-slot bus unit Panel PC 900 (Skylake) User's manual V 1.10...
System overview 3.3 Overview Order number Short description Page Accessories 0TB103.9 Connector 24 VDC - 3-pin, female - Screw clamp terminal block 3.31 mm² 0TB103.91 Connector 24 VDC - 3-pin, female - Cage clamp terminal block 3.31 mm² B&R Linux 10 5SWLIN.0864-MUL B&R Linux 10 - 64-bit - Multilingual - PPC900 chipset QM170/HM170 (UEFI boot) - Installation - Only available with a new device...
Page 21
System overview Order number Short description Page 5AP1120.1906-000 Automation Panel 19.0" SXGA TFT - 1280 x 1024 pixels (5:4) - Single-touch (analog resistive) - Control cabinet installation - Landscape format - Front USB - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules - Compatible with 5AP920.1906-01, 5PC720.1906-00, 5PC820.1906-00 5AP1130.156C-000 Automation Panel 15.6"...
Technical data 4 Technical data 4.1 Complete system 4.1.1 Product labels A unique serial number adhesive label with a barcode (Code 128) is affixed to each B&R device for identification purposes. This serial number represents all of the individual components built into the system (order number, name, revision, serial number, delivery date and duration of warranty).
Page 23
Technical data Searching for a serial number on the website Information: Using this function requires logging into the B&R website (www.br-automation.com). The serial number represents all of the individual components built into the system (serial number, material number, revision, delivery date and duration of warranty). This information is located on the B&R website. For this, the serial number of the complete system must be entered in the search field on the B&R website (www.br-automation.com).
Technical data 4.1.2 Environmental properties 4.1.2.1 Temperature specifications Depending on the display unit and system unit, CPU boards can be combined with various other components such as drives, main memory, additional plug-in cards, etc. The many different configurations possible result in varying maximum ambient temperatures, which can be seen in the following tables in this section.
Page 25
Technical data 4.1.2.1.2 Maximum ambient temperature for worst-case operation Operation with a fan kit All temperature specifications in degrees Celsius (°C) at Maximum ambient temperature (system unit 5PC911.SX00-00) 500 m above sea level, non-condensing. 5PC901.TS17-00 5PC901.TS17-01 5PC901.TS17-02 5PC901.TS17-03 The maximum ambient temperature is typically derated 1°C per 1000 meters i7 (6820EQ) i5 (6440EQ)
Page 26
Technical data Operation without a fan kit Boards 5PC901.TS17-00 and 5PC901.TS17-01 cannot be operated without a fan kit. All temperature specifications in degrees Celsius (°C) at Maximum ambient temperature (system unit 5PC911.SX00-01) 500 m above sea level, non-condensing. 5PC901.TS17-00 5PC901.TS17-01 5PC901.TS17-02 5PC901.TS17-03 The maximum ambient temperature is...
Page 27
Technical data 5CFAST.xxxx-10 ✓ ✓ PCIe cards 5ACPCE.ETH1-00 ✓ ✓ ✓ ✓ 5ACPCE.ETH4-00 The main memory module must be connected in RAM slot 2. The max. ambient temperature depends on the slide-in compact drive being used. For systems with a total system load >90 W, the max. ambient temperature must be reduced by 5°C. Panel PC 900 (Skylake) User's manual V 1.10...
Page 28
Technical data 4.1.2.1.3 Maximum ambient temperature for typical operation Information about typical conditions • BurnInTest 8.1 from PassMark Software for simulating moderate system and interface utilization (2D and 3D graphics, CPU, GPU, RAM, disks C and D, audio test and network on ping station) •...
Page 29
Technical data 5CFAST.xxxx-00 ✓ ✓ ✓ ✓ 5CFAST.xxxx-10 ✓ ✓ ✓ ✓ PCIe cards 5ACPCE.ETH1-00 5ACPCE.ETH4-00 The main memory module must be connected in RAM slot 2. The max. ambient temperature depends on the slide-in compact drive being used. Panel PC 900 (Skylake) User's manual V 1.10...
Page 30
Technical data Operation without a fan kit Boards 5PC901.TS17-00 and 5PC901.TS17-01 cannot be operated without a fan kit. All temperature specifications in degrees Celsius (°C) at Maximum ambient temperature (system unit 5PC911.SX00-01) 500 m above sea level, non-condensing. 5PC901.TS17-00 5PC901.TS17-01 5PC901.TS17-02 5PC901.TS17-03 The maximum ambient temperature is...
Page 31
Technical data 5CFAST.xxxx-10 ✓ ✓ PCIe cards 5ACPCE.ETH1-00 ✓ ✓ ✓ ✓ 5ACPCE.ETH4-00 The main memory module must be connected in RAM slot 2. The max. ambient temperature depends on the slide-in compact drive being used. For systems with a total system load >90 W, the max. ambient temperature must be reduced by 5°C. 4.1.2.1.4 Ambient temperature during storage and transport The individual components can be transported and stored within the following temperature ranges.
Page 32
Technical data Type Model number Storage [°C] Transport [°C] 5ACPCE.ETH1-00 -20 to 60 -20 to 60 PCIe cards 5ACPCE.ETH4-00 -20 to 60 -20 to 60 5AC901.IUPS-00 -20 to 60 -20 to 60 5AC901.IUPS-01 -20 to 60 -20 to 60 Uninterruptible power supplies 5AC901.BUPS-00 -65 to 80 -65 to 80...
Page 33
Technical data 4.1.2.1.5 Determining the ambient temperature 1. Select the system unit. 2. Select the CPU board. 3. The columns specify the maximum temperature of the complete system in connection with the respective CPU board. Information: Maximum temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level.
Page 34
Technical data 4.1.2.1.7 Temperature sensor positions Sensors show temperature values at various areas in the PPC900. These temperatures can be read out in BIOS (menu option Advanced - OEM features - System board features / CPU board features - Temperature values) or Microsoft Windows operating systems using the B&R Control Center Figure 5: Panel PC 900 - Temperature sensor positions ADI sensors...
Technical data 4.1.2.1.8 Fan control The MTCX constantly monitors the temperature using temperature sensors, which directly determines how the fans are controlled. Their speed depends on the measured temperature. Limit values may depend on the MTCX firmware version being used. Position Measurement point...
Technical data 4.1.2.2 Humidity specifications The following tables show the minimum and maximum relative humidity (at 30°C, non-condensing) of the individual components that are relevant for limiting the humidity of the complete system. The smallest or largest value must always be used for this determination. For more detailed information, see technical data or temperature/humidity diagrams of the individual components.
Technical data 4.1.2.3 Vibration and shock The following table provides an overview of the maximum vibrations and shock values of the complete system. Limitations are possible due to individual components. Vibration Operation Storage Transport 1)3) 1)3) Continuous Periodic With SSD drives and CFast cards 2 to 9 Hz: 2 to 9 Hz: 2 to 8 Hz: 7.5 mm amplitude...
Technical data 4.1.3 Mechanical properties 4.1.3.1 Dimensions AP9x3 display units - Dimensions Figure 6: Panel PC 900 with AP9x3 display units - Dimensions All dimensions in mm. Display type Model number 12.1" single-touch 5AP923.1215-00 13.5 15.0" single-touch 5AP923.1505-00 36.5 14.5 19.0"...
Page 39
Technical data AP1000 display units with retaining clips - Dimensions Figure 7: Panel PC 900 with AP1000 display units with retaining clips - Dimensions All dimensions in mm. Display type Model number 10.4" single-touch 5AP1120.1043-000 10.4" single-touch with keys 5AP1180.1043-000 15.6"...
Page 40
Technical data AP1000 display units with clamping blocks - Dimensions Figure 8: Panel PC 900 with AP1000 display units with clamping blocks - Dimensions All dimensions in mm. Display type Model number 10.4" single-touch with keys 5AP1181.1043-000 22.5 21.3 10.4" single-touch with keys 5AP1182.1043-000 355.5 22.5...
Technical data 4.1.3.2 Installation diagrams Information: When installing the Panel PC 900, spacing for air circulation and additional free space for operating and servicing the device must be taken into account. AP9x3 panels - Installation diagrams Figure 9: Panel PC 900 with AP9x3 display units - Installation diagram Panels Type Model number...
Page 42
Technical data AP1000 panels with retaining clips - Installation diagrams Figure 10: Panel PC 900 with AP1000 display units with retaining clips - Installation diagram All dimensions in mm. The cutout tolerances are +0 mm / -0.5 mm. Display type Model number Z min Z max...
Page 43
Technical data AP1000 panels with clamping blocks - Installation diagrams Figure 11: Panel PC 900 with AP1000 display units with retaining clips - Clamping blocks Panels Type Model number Z min. Z max. Number of clamping blocks 10.4" single-touch with keys 5AP1181.1043-000 10.4"...
Technical data 4.1.3.3 Spacing for air circulation To ensure sufficient air circulation, a specified clearance must be provided above, below, to the side and behind the device. For the minimum specified clearance, see the following diagrams. This is valid for all variants. Information: The following figure and table exclusively show the thermal view of the complete system.
Technical data 4.1.3.4 Mounting orientations The following diagrams show the specified mounting orientations of Panel PC 900 devices. An PPC900 system is only permitted to be installed as shown or described below. 0° 0° Mounting orientations when operated without a fan kit Mounting orientation Derating the ambient temperature 0°...
Technical data 4.1.4 Electrical properties 4.1.4.1 Power calculation In order to calculate the total power of the Panel PC, the power rating of the display being used must be entered in the "Display unit, permanent consumer" row of the table below. Information: The power supply's maximum total power of 130 watts is not permitted to be exceeded.
Page 48
Technical data In order to accurately determine the total power of the complete system, the values in this table must be entered in the power calculation table depending on the display unit being used. Type Order number +5 V +3.3 V +12 V Total power consumption...
Technical data 4.1.4.2 Block diagram The following block diagram shows the simplified structure of the Panel PC 900 complete system without a display unit. SO-DIMM DDR4 Ch A DDR4 (Skylake) Female connector 1 / 2 DDR4 Ch B Intel PCH Bus units 5AC902.BX01-00 5AC902.BX01-01...
Technical data 4.1.5 Device interfaces and slots 4.1.5.1 Overview of device interfaces The interfaces available on the device or module are numbered for the purpose of clear differentiation. The numbering used by the operating system may deviate, however. For all connections, only connections within a building are permitted, taking into account maximum lengths.
Technical data 4.1.5.2 Power supply The Panel PC can be operated with 24 VDC or optionally with 100~240 VAC. The 5AC902.PS00-00 power supply is required for AC power. For information about installing or replacing the power supply, see section "Installing or replacing the AC power supply"...
Technical data 4.1.5.2.2 Optional VAC power supply The optional 5AC902.PS00-00 power supply must be installed on the Panel PC in order to operate the Panel PC with AC power. The 3-pin male connector required for the power supply interface is not included in delivery. It can be ordered from B&R using model number 0TB3103.8000.
Technical data 4.1.5.4 Panel/Monitor interface Panel/Monitor interface - SDL (Smart Display Link) / DVI / RGB The following overview lists the video signals available on the panel/monitor output. For details, see the technical data for the CPU board being used. CPU board Video signals with all system unit variants 5PC901.TS17-00...
Page 54
Technical data 4.1.5.4.3 Cable lengths and resolutions for SDL transfer The following table shows the relationship between segment length and maximum resolution depending on the SDL cable: SDL cable Resolution SVGA SXGA UXGA Segment length [m] 640 x 480 800 x 600 1024 x 768 1366 x 768 1280 x 1024...
Technical data 4.1.5.5 Onboard Ethernet interfaces ETH1 This Ethernet controller is integrated in the CPU board and is routed externally via the system unit. Description Image Variant RJ45, female Controller Intel I219 Cabling S/STP (Cat 5e) Transfer rate 10/100/1000 Mbit/s Cable length Max.
Technical data 4.1.5.6 USB interfaces The Panel PC comes equipped with a USB 3.0 (Universal Serial Bus) host controller with multiple USB interfaces, 4 of which are accessible externally for the user. Warning! USB peripheral devices can be connected to the USB interfaces. Due to the variety of USB devices available on the market, B&R cannot guarantee their functionality.
Technical data 4.1.5.7 CFast slot The PPC900 offers an easy-to-access CFast slot behind its front cover so that a CFast card can be used as a removable storage medium for transferring data or performing upgrades. This CFast slot is connected to the chipset internally via SATA 1 with SATA III design (SATA 6 Gbit/s). Description Figure Connection...
Technical data 4.1.5.9 LED status indicators The LED status indicators are located on the right-hand side of the Panel PC when viewed from the front. The following timing is used for the LED status indicators: Block size: 250 ms Repeat interval: 500 ms, 2 boxes thus represent one interval Assignment Color Status...
Technical data 4.1.5.10 Power button / Reset button Due to full ATX power supply support, the power button has various functions. Description Figure The power button can be pressed with a pointed object (e.g. tip of a pen). The power button behaves like the power switch on current desktop PCs with an ATX power supply: Short press: Switches on the Automation PC or performs the action configured in the operating system when pressing the power button (shutdown, sleep, etc.) and switches off the Automation PC.
Technical data 4.1.5.11 Battery The lithium battery (3 V, 950 mAh) buffers the internal real-time clock (RTC). It is located on the back of the Panel PC. The battery is installed in a battery holder, making it very easy to replace. The self-discharge time of the battery is at least 4 years (at 50°C, 8.5 μA for the components being supplied and self-discharge of 40%).
Technical data 4.1.5.12 Slide-in compact slot The slide-in compact slot is connected to the chipset internally via SATA 0 with SATA III design (SATA 6.0 Gbit/s). Description Figure Connection SATA 0 Model number Short description Drives 5AC901.CHDD-01 500 GB hard disk - Slide-in compact - SATA 5AC901.CSSD-03 60 GB SSD MLC - Slide-in compact - SATA 5AC901.CSSD-04...
Technical data 4.1.5.14 Main memory slots The Panel PC 900 provides 2 slots for DDR4 main memory modules. Description Figure Velocity DDR4-2133 (PC4-17000) Order number Short description Main memory 5MMDDR.4096-04 SO-DIMM DDR4, 4096 MB 5MMDDR.8192-04 SO-DIMM DDR4, 8192 MB 5MMDDR.016G-04 SO-DIMM DDR4, 16 GB Information: For information about replacing or installing a main memory module, see section...
Technical data 4.1.5.15 IF options PPC900 system units have 2 slots for interface options: • IF option 1 slot (1) • IF option 2 slot (2) Information: For information about replacing or installing an interface option, see section Installing the inter- face option.
Technical data 4.1.5.16 Card slot (PCI / PCIe) If a bus unit is installed in the Panel PC 900, the bus unit variant being used will determine whether standard PCI 2.2 half-size cards or PCI Express (PCIe) half-size cards can be inserted. They must not exceed the following dimensions.
Technical data 4.1.6 Layout of AP1000 display units A wide selection of different display sizes and display units with touch screen are available. The following table provides an overview of the display units and their features. Display type Model number Resolution Touch screen Function keys...
Technical data 4.1.6.2 Key and LED configuration Each key and LED can be individually configured and adapted to the application. Various tools from B&R are available for configuration: • B&R Key Editor for Windows operating systems • B&R KCF Editor for Windows operating systems •...
Page 67
Technical data 5AP1181.1043-000 5AP1182.1043-000 5AP1180.1505-000 Panel PC 900 (Skylake) User's manual V 1.10...
Page 68
Technical data 5AP1181.1505-000 Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.1.6.3 USB interface AP1000 panels with 10.4", 12.1" (4:3 format only), 15" and 19" display diagonals are equipped with a USB 2.0 interface on the front. This is equipped with a USB interface cover. IP65 protection (front) is only provided if the USB interface cover is correctly installed.
Technical data 4.2 Individual components 4.2.1 AP9x3 panels 4.2.1.1 5AP923.1215-00 4.2.1.1.1 General information • Panel for AP9x3, PPC900, PPC2100, PPC2200 or PPC3100 • 12.1" TFT XGA color display • Single-touch (analog resistive) • Control cabinet installation 4.2.1.1.2 Order data Order number Short description Figure Panels...
Technical data Order number 5AP923.1215-00 Mechanical properties Front Frame Aluminum, coated Panel overlay Material Polyester Light background color RAL 9006 Dark border color around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 315 mm Height 239 mm Weight 2200 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
Technical data 4.2.1.2 5AP923.1505-00 4.2.1.2.1 General information • Panel for AP9x3, PPC900, PPC2100, PPC2200 or PPC3100 • 15.0" TFT XGA color display • Single-touch (analog resistive) • Control cabinet installation 4.2.1.2.2 Order data Order number Short description Figure Panels 5AP923.1505-00 Automation Panel 15.0"...
Page 73
Technical data Order number 5AP923.1505-00 Mechanical properties Front Frame Aluminum, coated Panel overlay Material Polyester Light background color RAL 9006 Dark border color around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 370 mm Height 288 mm Weight 3700 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
Technical data 4.2.1.3 5AP923.1906-00 4.2.1.3.1 General information • Panel for AP9x3, PPC900, PPC2100, PPC2200 or PPC3100 • 19.0" TFT SXGA color display • Single-touch (analog resistive) • Control cabinet installation 4.2.1.3.2 Order data Order number Short description Figure Panels 5AP923.1906-00 Automation Panel 19.0"...
Page 75
Technical data Order number 5AP923.1906-00 Revision Mechanical properties Front Frame Aluminum, coated Panel overlay Material Polyester Light background color RAL 9006 Dark border color around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 440 mm Height 358 mm Weight 5800 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
Page 76
Technical data 5AP923.1906-00 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.1.4 5AP933.156B-00 4.2.1.4.1 General information • Panel for AP9x3, PPC900, PPC2100, PPC2200 or PPC3100 • 15.6" TFT HD color display • Multi-touch (PCT) • Control cabinet installation 4.2.1.4.2 Order data Order number Short description Figure Panels 5AP933.156B-00 Automation Panel 15.6" HD TFT - 1366 x 768 pixels (16:9) - Multi-touch (projected capacitive) - Control cabinet installation - Landscape format - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules...
Page 78
Technical data 4.2.1.4.4 Dimensions 4.2.1.4.5 Temperature/Humidity diagram 5AP933.156B-00 ≥ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5AP933.156B-00 ≤...
Technical data 4.2.1.5 5AP933.185B-00 4.2.1.5.1 General information • Panel for AP9x3, PPC900, PPC2100, PPC2200 or PPC3100 • 18.5" TFT HD color display • Multi-touch (PCT) • Control cabinet installation 4.2.1.5.2 Order data Order number Short description Figure Panels 5AP933.185B-00 Automation Panel 18.5" HD TFT - 1366 x 768 pixels (16:9) - Multi-touch (projected capacitive) - Control cabinet installation - Landscape format - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules...
Page 80
Technical data 4.2.1.5.4 Dimensions 4.2.1.5.5 Temperature/Humidity diagram 5AP933.185B-00 ≥ Rev. D0 RH [%] T [°C] -20 - 0 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5AP933.185B-00 ≤ Rev. C0 RH [%] T [°C] -20 - 0...
Technical data 4.2.1.6 5AP933.215C-00 4.2.1.6.1 General information • Panel for AP9x3, PPC900, PPC2100, PPC2200 or PPC3100 • 21.5" TFT FHD color display • Multi-touch (PCT) • Control cabinet installation 4.2.1.6.2 Order data Order number Short description Figure Panels 5AP933.215C-00 Automation Panel 21.5" Full HD TFT - 1920 x 1080 pixels (16:9) - Multi-touch (projected capacitive) - Control cabinet installation - Landscape format - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules...
Page 82
Technical data 4.2.1.6.4 Dimensions 541.5 4.2.1.6.5 Temperature/Humidity diagram 5AP933.215C-00 ≥ Rev. D0 RH [%] T [°C] -20 - 0 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5AP933.215C-00 ≤ Rev. C0 RH [%] T [°C] -20 - 0...
Technical data 4.2.1.7 5AP933.240C-00 4.2.1.7.1 General information • Panel for AP9x3, PPC900, PPC2100, PPC2200 or PPC3100 • 24" TFT FHD color display • Multi-touch (PCT) • Control cabinet installation 4.2.1.7.2 Order data Order number Short description Figure Panels 5AP933.240C-00 Automation Panel 24.0" Full HD TFT - 1920 x 1080 pixels (16:9) - Multi-touch (projected capacitive) - Control cabinet installation - Landscape format - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules...
Page 84
Technical data Order number 5AP933.240C-00 Revision Dimensions Width 598.5 mm Height 364 mm Weight Approx. 7800 g Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV certificate for the product family.
Page 85
Technical data 5AP933.240C-00 ≤ Rev. C0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.2 AP1000 panels 4.2.2.1 5AP1120.1043-000 4.2.2.1.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 10.4" TFT VGA color display • Single-touch (analog resistive) • Front USB interface • Control cabinet installation 4.2.2.1.2 Order data Order number Short description Figure...
Page 87
Technical data Order number 5AP1120.1043-000 Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65...
Technical data 4.2.2.2 5AP1180.1043-000 4.2.2.2.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 10.4" TFT VGA color display • Single-touch (analog resistive) • 22 function keys • Front USB interface • Control cabinet installation 4.2.2.2.2 Order data Order number Short description Figure...
Page 89
Technical data Order number 5AP1180.1043-000 Keys Function keys 22 with LED (yellow) System keys Service life >1,000,000 actuations at 1 ±0.3 N to 3 ±0.3 N actuating force LED luminous intensity Yellow Typ. 38 mcd Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65...
Technical data 4.2.2.3 5AP1181.1043-000 4.2.2.3.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 10.4" TFT VGA color display • Single-touch (analog resistive) • 38 function keys and 20 system keys • Front USB interface • Control cabinet installation 4.2.2.3.2 Order data Order number Short description...
Page 91
Technical data Order number 5AP1181.1043-000 Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Keys Function keys 38 with LED (yellow) System keys Numeric keys, cursor block Service life...
Page 92
Technical data 4.2.2.3.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.2.4 5AP1182.1043-000 4.2.2.4.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 10.4" TFT VGA color display • Single-touch (analog resistive) • 44 function keys and 20 system keys • Front USB interface • Control cabinet installation 4.2.2.4.2 Order data Order number Short description...
Page 94
Technical data Order number 5AP1182.1043-000 System keys Numeric keys, cursor block Service life >1,000,000 actuations at 1 ±0.3 N to 3 ±0.3 N actuating force LED luminous intensity Yellow Typ. 38 mcd Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit)
Technical data 4.2.2.5 5AP1120.1214-000 4.2.2.5.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 12.1" TFT SVGA color display • Single-touch (analog resistive) • Front USB interface • Control cabinet installation 4.2.2.5.2 Order data Order number Short description Figure Panels 5AP1120.1214-000...
Page 96
Technical data Order number 5AP1120.1214-000 Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Mechanical properties Front...
Technical data 4.2.2.6 5AP1120.1505-000 4.2.2.6.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 15.0" TFT XGA color display • Single-touch (analog resistive) • Front USB interface • Control cabinet installation 4.2.2.6.2 Order data Order number Short description Figure Panels 5AP1120.1505-000...
Page 98
Technical data Order number 5AP1120.1505-000 Degree of protection per EN 60529 Front: IP65 Back: IP20 (only with installed link module or installed system unit) Degree of protection per UL 50 Front: Type 4X indoor use only Mechanical properties Front Frame Aluminum, naturally anodized Panel overlay Material...
Technical data 4.2.2.7 5AP1180.1505-000 4.2.2.7.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 15.0" TFT XGA color display • Single-touch (analog resistive) • 32 function keys • Front USB interface • Control cabinet installation 4.2.2.7.2 Order data Order number Short description Figure...
Page 100
Technical data Order number 5AP1180.1505-000 Keys Function keys 32 with LED (yellow) System keys Service life >1,000,000 actuations at 1 ±0.3 N to 3 ±0.3 N actuating force LED luminous intensity Yellow Typ. 38 mcd Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65...
Technical data 4.2.2.8 5AP1181.1505-000 4.2.2.8.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 15.0" TFT XGA color display • Single-touch (analog resistive) • 32 function keys • 92 system keys • Front USB interface • Control cabinet installation Information: This Automation Panel is not approved for DVI operation.
Page 102
Technical data Order number 5AP1181.1505-000 Touch screen Technology Analog, resistive Controller B&R, serial, 12-bit Transmittance 81% ±3% Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max.
Page 103
Technical data 4.2.2.8.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.2.9 5AP1120.156B-000 4.2.2.9.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 15.6" TFT HD color display • Single-touch (analog resistive) • Control cabinet installation 4.2.2.9.2 Order data Order number Short description Figure Panels 5AP1120.156B-000 Automation Panel 15.6"...
Page 105
Technical data Order number 5AP1120.156B-000 Mechanical properties Front Frame Aluminum, coated Panel overlay Material Polyester Light background color RAL 9006 Dark border color around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 414 mm Height 258.5 mm Weight 4200 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
Page 106
Technical data Up to hardware revision G0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.2.10 5AP1130.156C-000 4.2.2.10.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 15.6" FHD color display • Multi-touch (projected capacitive) • Control cabinet installation 4.2.2.10.2 Order data Order number Short description Figure Panels 5AP1130.156C-000 Automation Panel 15.6" Full HD TFT - 1920 x 1080 pixels (16:9) - Multi-touch (projected capacitive) - Control cabinet installation - Landscape format - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules...
Page 108
Technical data Order number 5AP1130.156C-000 Dimensions Width 414 mm Height 258.5 mm Weight 3700 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark. Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV certificate for the product family.
Technical data 4.2.2.11 5AP1130.156C-001 4.2.2.11.1 General information • Panel for AP1000, PPC2100, PPC2200 or PPC3100 • 15.6" TFT WXGA color display • Multi-touch (projected capacitive) • Manufactured with optical bonding technology 4.2.2.11.2 Order data Order number Short description Figure Panels 5AP1130.156C-001 Automation Panel 15.6"...
Page 110
Technical data Order number 5AP1130.156C-001 Dimensions Width 414 mm Height 258.5 mm Weight Approx. 3,800 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark. At 25°C ambient temperature. Reducing the brightness by 50% can increase the half-brightness time by approximately 50%. The specifications for the touch screen driver must be taken into account.
Technical data 4.2.2.12 5AP1130.185C-000 4.2.2.12.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 18.5" FHD color display • Multi-touch (projected capacitive) • Control cabinet installation 4.2.2.12.2 Order data Order number Short description Figure Panels 5AP1130.185C-000 Automation Panel 18.5" Full HD TFT - 1920 x 1080 pixels (16:9) - Multi-touch (projected capacitive) - Control cabinet installation - Landscape format - For PPC900/PPC2100/PPC3100/PPC2200 - For link modules...
Page 112
Technical data Order number 5AP1130.185C-000 Dimensions Width 475 mm Height 295 mm Weight 4700 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark. Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV certificate for the product family.
Technical data 4.2.2.13 5AP1120.1906-000 4.2.2.13.1 General information • Panel for AP1000, PPC900, PPC2100, PPC2200 or PPC3100 • 19.0" TFT SXGA color display • Single-touch (analog resistive) • Front USB interface • Control cabinet installation 4.2.2.13.2 Order data Order number Short description Figure Panels 5AP1120.1906-000...
Page 114
Technical data Order number 5AP1120.1906-000 Interfaces Quantity Type USB 2.0 Variant Type A Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) Current-carrying capacity Max. 500 mA Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Degree of protection per EN 60529 Front: IP65...
Page 115
Technical data 4.2.2.13.5 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.3 QM170 CPU boards 4.2.3.1 5PC901.TS17-00, -01 4.2.3.1.1 General information • Intel Core i-series processors • Intel QM170 chipset • 2x DDR4 memory slots • Intel Gen 9 HD graphics • AMI BIOS (UEFI) Information: A fan kit is required when using CPU boards 5PC901.TS17-00 and 5PC901.TS17-01. 4.2.3.1.2 Order data Order number Short description...
Page 117
Technical data Order number 5PC901.TS17-00 5PC901.TS17-01 Processor Type Intel Core i7-6820EQ Intel Core i5-6440EQ Clock frequency 2800 MHz 2700 MHz Number of cores Architecture 14 nm Thermal design power (TDP) 45 W Intel Smart Cache 8 MB 6 MB External bus DMI3, 8 GT/s Intel 64 architecture Intel Turbo Boost Technology...
Page 118
Technical data Order number 5PC901.TS17-00 5PC901.TS17-01 Audio Type Controller Realtek RTL888 Inputs Microphone, Line In Outputs Line Out Slots Slide-in compact drives Quantity Type SATA III (SATA 6.0 Gbit/s) Interface option Add-on UPS slot Slot for fan kit Electrical properties Nominal voltage 24 VDC, SELV 24 VDC ±25%, SELV...
Technical data 4.2.4 HM170 CPU boards 4.2.4.1 5PC901.TS17-02, -03 4.2.4.1.1 General information • Intel Celeron and Intel Core i processors • Intel HM170 chipset • 2x DDR4 memory slots • Intel Gen 9 HD graphics • AMI BIOS (UEFI) Information: The following applies when operated without a fan kit: •...
Page 120
Technical data Order number 5PC901.TS17-02 5PC901.TS17-03 Processor Type Intel Core i3-6100E Intel Celeron G3900E Clock frequency 2700 MHz 2400 MHz Number of cores Architecture 14 nm Thermal design power (TDP) 35 W Intel Smart Cache 3 MB 2 MB External bus DMI3, 8 GT/s Intel 64 architecture Intel Turbo Boost Technology...
Page 121
Technical data Order number 5PC901.TS17-02 5PC901.TS17-03 Audio Type Controller Realtek RTL888 Inputs Microphone, Line In Outputs Line Out Slots Slide-in compact drives Quantity Type SATA III (SATA 6.0 Gbit/s) Interface option Add-on UPS slot Slot for fan kit Electrical properties Nominal voltage 24 VDC ±25%, SELV Nominal current...
Technical data 4.2.5 System units 4.2.5.1 5PC911.SX00-00 4.2.5.1.1 General information The active Panel PC 900 system unit consists of a housing and heat sink. A fan kit is also required for operation. A CPU board, main memory, IF options, fan kit and slide-in compact drive are installed in the system unit. The 5AC902.FA00-00 fan kit is not included with the system unit and must be ordered separately.
Technical data 4.2.5.2 5PC911.SX00-01 4.2.5.2.1 General information The passive Panel PC 900 system unit consists of a housing and heat sink. A CPU board, main memory, IF options and slide-in compact drive are installed in the system unit. 4.2.5.2.2 Order data Order number Short description Figure...
Technical data 4.2.6 Main memory 4.2.6.1 5MMDDR.xxxx-04 4.2.6.1.1 General information These 260-pin DDR4 main memory modules operate with a data rate of 2133 MHz and are available in sizes ranging from 4 GB to 16 GB. If two main memory modules of identical size (e.g. 4 GB) are connected to the CPU board, then dual-channel memory technology is supported.
Technical data 4.2.7 Bus units Information: For information about installing or replacing a bus unit, please refer to the section "Installing the bus unit" on page 222. When installing or replacing a bus unit, it is also necessary to load the default settings in BIOS Setup (Save &...
Page 126
Technical data 4.2.7.1.2 Order data Order number Short description Figure Bus units 5AC902.BX01-00 PPC900 bus unit, 1-slot - 1 PCI - 1 slide-in 5AC902.BX01-01 PPC900 bus unit, 1-slot - 1 PCI Express x8 - 1 slide-in 5AC902.BX02-00 PPC900 bus unit, 2-slot - 2 PCI - 1 slide-in 5AC902.BX02-01 PPC900 2-slot bus unit - 1 PCI - 1 PCI Express x8 - 1 slide-in 5AC902.BX02-02...
Technical data 4.2.8 Fan kit Information: Fan kits are subject to wear and must be checked at appropriate intervals and cleaned or replaced when not functioning properly (e.g. due to dirt and grime). For information about replacing fan filters, please refer to the section "Replacing the fan filter"...
Technical data 4.2.8.2 5AC902.FA0X-00 4.2.8.2.1 General information This fan kit includes a fan that is installed to improve the heat dissipation of a PPC900 bus unit. • 1 fan for improved heat dissipation on the bus unit • Simple installation and removal The fan kit is not included in the delivery of the bus unit and must be ordered separately.
Technical data 4.2.9 Drives Information: Current information, such as revision-dependent technical data, is available on the B&R website. 4.2.9.1 5AC901.CHDD-01 4.2.9.1.1 General information This 500 GB slide-in compact hard disk is specified for 24-hour operation. The slide-in compact drive can be used in APC910 and PPC900 system units.
Page 130
Technical data Order number 5AC901.CHDD-01 Supported transfer modes SATA II Data transfer rate Internal Max. 147 MB/s To/From host Max. 150 Mbit/s (SATA I), max. 300 Mbit/s (SATA II) Positioning time Nominal (read access) 11 ms Maximum (read access) 21 ms Operating conditions Pollution degree per EN 61131-2 Pollution degree 2...
Technical data 4.2.9.1.4 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.9.2 5AC901.CSSD-03 4.2.9.2.1 General information This 60 GB slide-in compact solid-state drive (SSD) is based on multi-level cell (MLC) technology and is SATA 3.0 compatible. The slide-in compact drive can be used in APC910 and PPC900 system units. •...
Page 133
Technical data Order number 5AC901.CSSD-03 Revision Interface SATA Servicing None Continuous reading Max. 510 MB/s Continuous writing Max. 430 MB/s IOPS 4k read Max. 50,000 (random) 4k write Max. 25,000 (random) Endurance MLC flash memory Guaranteed data volume Guaranteed 35 TBW 47 TBW Compatibility SATA 3.0 compliant...
Page 134
Technical data 4.2.9.2.4 Temperature/Humidity diagram 5AC901.CSSD-03 Rev. F0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5AC901.CSSD-03 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10...
Technical data 4.2.9.3 5AC901.CSSD-04 4.2.9.3.1 General information This 128 GB slide-in compact solid-state drive (SSD) is based on multi-level cell (MLC) technology and is SATA 3.0 compatible. The slide-in compact drive can be used in APC910 and PPC900 system units. •...
Page 136
Technical data Order number 5AC901.CSSD-04 Revision Interface SATA Servicing None Continuous reading Max. 510 MB/s Continuous writing Max. 450 MB/s IOPS 4k read Max. 80,000 (random) Max. 85,000 (random) 4k write Max. 35,000 (random) Endurance MLC flash memory Guaranteed data volume Guaranteed 74 TBW 100 TBW...
Page 137
Technical data 4.2.9.3.4 Temperature/Humidity diagram 5AC901.CSSD-04 Rev. G0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5AC901.CSSD-04 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10...
Technical data 4.2.9.4 5AC901.CSSD-05 4.2.9.4.1 General information This 256 GB slide-in compact solid-state drive (SSD) is based on multi-level cell (MLC) technology and is SATA 3.0 compatible. The slide-in compact drive can be used in APC910 and PPC900 system units. •...
Page 139
Technical data Order number 5AC901.CSSD-05 Revision Interface SATA Servicing None Continuous reading Max. 510 MB/s Continuous writing Max. 460 MB/s IOPS 4k read Max. 90,000 (random) 4k write Max. 35,000 (random) Endurance MLC flash memory Data volume Theoretical 768 TBW Client workload 148 TBW 200 TBW...
Page 140
Technical data 4.2.9.4.4 Temperature/Humidity diagram 5AC901.CSSD-05 ≥ Rev. E0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5AC901.CSSD-05 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10...
Technical data 4.2.9.5 5AC901.CSSD-06 4.2.9.5.1 General information This 512 GB slide-in compact solid-state drive (SSD) is based on multi-level cell (MLC) technology and is SATA 3.0 compatible. The slide-in compact drive can be used in APC910 and PPC900 system units. •...
Page 142
Technical data Order number 5AC901.CSSD-06 Endurance MLC flash memory Data volume Theoretical 1536 TBW Client workload 400 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature...
Technical data 4.2.9.6 5AC901.CSSD-07 4.2.9.6.1 General information This 1 TB slide-in compact solid-state drive (SSD) is based on multi-level cell (MLC) technology and SATA 3.0 compatible. The slide-in compact drive can be used in APC910 and PPC900 system units. • 1 TB solid-state drive •...
Page 144
Technical data Order number 5AC901.CSSD-07 Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature Operation -40 to 85°C Storage -55 to 95°C Transport -55 to 95°C Relative humidity Operation 10 to 95%, non-condensing Storage 10 to 95%, non-condensing Transport 10 to 95%, non-condensing Vibration...
Technical data 4.2.9.7 5MMSSD.0060-01 4.2.9.7.1 General information This 60 GB solid-state drive (SSD) drive can be used as a replacement part or accessory. The SSD is based on Multi Level Cell (MLC) technology. • Replacement for 5AC801.SSDI-03 or 5AC901.CSSD-03 SSD drives •...
Page 146
Technical data Order number 5MMSSD.0060-01 Revision Endurance MLC flash memory Data volume Theoretical 192 TBW Client workload 35 TBW 47 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature...
Page 147
Technical data 5MMSSD.0060-01 Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5MMSSD.0060-01 ≥ Rev. E0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend...
Technical data 4.2.9.8 5MMSSD.0128-01 4.2.9.8.1 General information This 128 GB solid-state drive (SSD) drive can be used as a replacement part or accessory. The SSD is based on Multi Level Cell (MLC) technology. • Replacement for 5AC801.SSDI-04 or 5AC901.CSSD-04 SSD drives •...
Page 149
Technical data Order number 5MMSSD.0128-01 Revision Endurance MLC flash memory Data volume Theoretical 384 TBW Client workload 74 TBW 100 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature...
Page 150
Technical data 5MMSSD.0128-01 Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing 5MMSSD.0128-01 ≥ Rev. E0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend...
Technical data 4.2.9.9 5MMSSD.0256-00 4.2.9.9.1 General information This 256 GB solid-state drive (SSD) drive can be used as a replacement part or accessory. The SSD is based on Multi Level Cell (MLC) technology. • Replacement for 5AC801.SSDI-05 or 5AC901.CSSD-05 SSD drives •...
Page 152
Technical data Order number 5MMSSD.0256-00 Revision Endurance MLC flash memory Data volume Theoretical 768 TBW Client workload 148 TBW 200 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature...
Page 153
Technical data 5MMSSD.0256-00 ≤ Rev. D0 RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.9.10 5MMSSD.0512-00 4.2.9.10.1 General information This 512 GB solid-state drive (SSD) drive can be used as a replacement part or accessory. The SSD is based on Multi Level Cell (MLC) technology. • Replacement for the SSD drive 5AC901.CSSD-06 4.2.9.10.2 Order data Order number Short description...
Page 155
Technical data Order number 5MMSSD.0512-00 Vibration Operation 10 to 2000 Hz: 20 g Storage 10 to 2000 Hz: 20 g Transport 10 to 2000 Hz: 20 g Shock Operation 1500 g, 0.5 ms Storage 1500 g, 0.5 ms Transport 1500 g, 0.5 ms Mechanical properties Dimensions Width...
Technical data 4.2.9.11 5MMSSD.1024-00 4.2.9.11.1 General information This 1 TB solid-state drive (SSD) drive can be used as a replacement part. The SSD is based on multi-level cell (MLC) technology. • Replacement drive for 5AC901.CSSD-C00 SSD drive 4.2.9.11.2 Order data Order number Short description Figure...
Page 157
Technical data Order number 5MMSSD.1024-00 Data volume Theoretical 3072 TBW Client workload 1172 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Ambient conditions Temperature Operation 0 to 70°C Storage -40 to 85°C Transport -40 to 85°C Relative humidity...
Technical data 4.2.9.12 5AC901.CHDD-99 4.2.9.12.1 General information The slide-in compact kit can be used as a replacement part for the slide-in compact drives (HDD/SSD). It consists of a removal strip, plastic guide rails and the necessary screws. Information: If this slide-in compact kit is used with components not approved by B&R (HDD/SSD), B&R cannot guarantee its fit, form and function.
Technical data 4.2.9.13 5AC901.CCFA-00 4.2.9.13.1 General information This CFast adapter is a slide-in compact adapter that allows a CFast card to be inserted and operated on a B&R industrial PC. The CFast adapter can be used in APC910 and PPC900 system units. •...
Technical data 4.2.9.14 5AC901.SDVW-00 4.2.9.14.1 General information The DVD-R/RW slide-in drive can be used in APC910 system units and PPC900 bus units with a slide-in drive slot. • DVD-R/RW, DVD+R/RW drive • Slide-in 4.2.9.14.2 Order data Order number Short description Figure Drives 5AC901.SDVW-00...
Page 161
Technical data Order number 5AC901.SDVW-00 Access time On average 140 ms (24x) On average 150 ms (8x) Readable media CD/CD-ROM (12 cm, 8 cm), CD-R, CD-RW DVD-ROM, DVD-R, DVD-R (dual layer), DVD-RW. DVD- RAM, DVD+R, DVD+R (dual layer), DVD+RW, DVD-RAM Writable media CD-R, CD-RW DVD-R/RW, DVD-R (dual layer), DVD-RAM (4.7 GB), DVD+R/RW, DVD+R (dual layer)
Page 162
Technical data 4.2.9.14.4 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage RH [%] Relative humidity (RH) in percent and non-condensing Transport Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.9.15 5AC901.SSCA-00 4.2.9.15.1 General information The slide-in compact adapter is a slide-in adapter that allows a slide-in compact drive to be installed and operated on a B&R industrial PC. The slide-in compact adapter can be used in APC910 system units and PPC900 bus units. •...
Page 164
Technical data Order number 5AC901.SSCA-00 Relative humidity Operation Depends on the slide-in compact drive being used Storage Depends on the slide-in compact drive being used Transport Depends on the slide-in compact drive being used Table 102: 5AC901.SSCA-00 - Technical data Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
Technical data 4.2.10 Interface options 4.2.10.1 5AC901.I232-00 4.2.10.1.1 General information Interface option 5AC901.I232-00 is equipped with an RS232 interface. • 1x RS232 interface • Compatible with APC910/PPC900 and APC3100/PPC3100 4.2.10.1.2 Order data Order number Short description Figure Interface options 5AC901.I232-00 Interface card - 1x RS232 interface - For APC910/PPC900/ APC3100/PPC3100 4.2.10.1.3 Technical data...
Page 166
Technical data 4.2.10.1.3.1 Pinout Serial interface COM RS232 Variant DSUB, 9-pin, male Type RS232, modem supported UART 16550-compatible, 16-byte FIFO buffer Galvanic isolation Transfer rate Max. 115 kbit/s Bus length Max. 15 m Pinout The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the numbering used by the respective operating system, however.
Technical data 4.2.10.2 5AC901.I485-00 4.2.10.2.1 General information Interface option 5AC901.I485-00 is equipped with an RS232/RS422/RS485 interface. The operating mode (RS232/ RS422/RS485) is selected automatically depending on the electrical connection. • 1x RS232/RS422/RS485 interface • Compatible with APC910/PPC900 and APC3100/PPC3100 4.2.10.2.2 Order data Order number Short description Figure...
Page 168
Technical data Order number 5AC901.I485-00 Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 34 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark. Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for the product family.
Technical data 4.2.10.2.3.4 Operation as RS485 interface The pins of the RS422 default interface (1, 4, 6 and 9) must be used for operation. To do this, connect the pins as shown. DATA DATA Figure 19: RS232/RS422/RS485 interface - Operation in RS485 mode The RTS line must be switched by the driver for each transmission or reception;...
Technical data 4.2.10.3 5AC901.ICAN-00 4.2.10.3.1 General information Interface option 5AC901.ICAN-00 is equipped with a CAN bus master interface. • 1x CAN bus master interface • Compatible with APC910/PPC900 and APC3100/PPC3100 Simultaneous operation of 2 interface options with a legacy CAN interface in slots IF option 1 and IF option 2 is not possible.
Page 171
Technical data Order number 5AC901.ICAN-00 Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 33 g Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark. Yes, although applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for the product family.
Page 172
Technical data 4.2.10.3.3.6 Drivers Drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com) (if required and not already included in the operating system). Approved operating systems: • Windows 10 • Automation Runtime Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.10.4 5AC901.ICAN-01 4.2.10.4.1 General information Interface option 5AC901.ICAN-01 is equipped with a CAN bus master interface. • 1x CAN bus master interface (SJA1000) • Compatible with APC910/PPC900 and APC3100/PPC3100 Simultaneous operation of 2 interface options with a legacy CAN interface in slots IF option 1 and IF option 2 is not possible.
Page 174
Technical data 4.2.10.4.3.1 Pinout CAN bus Variant DSUB, 9-pin, male Galvanic isolation Transfer rate Max. 1 Mbit/s Bus length Max. 1000 meters Pinout CAN LOW Reserved CAN HIGH Not connected 4.2.10.4.3.2 I/O address and IRQ Resource Default setting Function I/O address 384h (address register) Defines the register number to be accessed.
Technical data 4.2.10.5 5AC901.ISRM-00 4.2.10.5.1 General information Interface option 5AC901.ISRM-00 is equipped with 2 MB SRAM. • 2 MB SRAM • Compatible with APC910/PPC900 and APC3100/PPC3100 This interface option can only be operated in slot IF option 2. 4.2.10.5.2 Order data Order number Short description Figure...
Page 176
Technical data 4.2.10.5.3.1 Drivers Drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com) (if required and not already included in the operating system). Approved operating systems: • Windows 10 • B&R Linux Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.10.6 5AC901.IPLK-00 4.2.10.6.1 General information Interface option 5AC901.IPLK-00 is equipped with 1 POWERLINK interface and 2 MB SRAM. • 1x POWERLINK interface managing or controlled node • 2 MB SRAM • Compatible with APC910/PPC900 and APC3100/PPC3100 This interface option can only be operated in slot IF option 2. 4.2.10.6.2 Order data Order number Short description...
Page 178
Technical data Order number 5AC901.IPLK-00 Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 35 g Yes, although applies only if all components installed within the complete system have this certification and the complete system itself carries the corresponding mark.
Technical data 4.2.10.7 5AC901.IHDA-00 4.2.10.7.1 General information Interface option 5AC901.IHDA-00 is equipped with an HDA sound chip with externally accessible MIC, Line IN and Line OUT channels. • 1x MIC • 1x Line IN • 1x Line OUT • Compatible with APC910/PPC900 and APC3100/PPC3100 This interface option can only be operated in slot IF option 1.
Page 180
Technical data Order number 5AC901.IHDA-00 Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 21 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark. Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for the product family.
Technical data 4.2.10.8 5AC901.IRDY-00 4.2.10.8.1 General information Ready relay 5AC901.IRDY-00 is switched as soon as the B&R industrial PC has started up and all internal supply voltages are applied. It is possible to connect additional devices to the ready relay; they will also be switched on when the B&R industrial PC starts up.
Technical data 4.2.10.9 5AC901.ISIO-00 4.2.10.9.1 General information The ready relay function of IF option 5AC901.ISIO-00 can be controlled using the MTCX. Corresponding commands must be issued by the MTCX in order to switch the ready relay. In addition to the ready relay function, the reset and power button as well as the power LED of the APC910/PPC900 or APC3100/PPC3100 can be routed externally.
Technical data Order number 5AC901.ISIO-00 Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 30 g Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV certificate for the product family.
Technical data 4.2.10.10 5AC901.IETH-00 4.2.10.10.1 General information Interface option 5AC901.IETH-00 is equipped with a 10/100/1000BASE-T Ethernet interface. • 1x Ethernet interface 10/100/1000BASE-T • Compatible with APC910/PPC900 and APC3100/PPC3100 This interface option can only be operated in slot IF option 2. 4.2.10.10.2 Order data Order number Short description...
Page 185
Technical data 4.2.10.10.3.1 Pinout Ethernet interface (ETH Variant RJ45, female Controller Intel I210 Wiring S/STP (Cat 5e) Transfer rate 10/100/1000 Mbit/s Cable length Max. 100 m (min. Cat 5e) LED "Speed" (a) Green 100 Mbit/s 10 Mbit/s Orange (light) 1000 Mbit/s LED "Link"...
Technical data 4.2.11 Uninterruptible power supply (UPS) With the optionally integrated UPS, the B&R industrial PC ensures that the PC system can complete write oper- ations even after a power failure occurs. If the UPS detects a power failure, it switches to battery operation im- mediately without interruption.
Technical data 4.2.11.2 5AC901.IUPS-00 4.2.11.2.1 General information UPS IF option 5AC901.IUPS-00 used together with battery unit 5AC901.BUPS-00 allows the B&R industrial PC to be switched off properly without data loss during a power failure. This interface option can only be operated in slot IF option 1. Warning! UPS IF option 5AC901.IUPS-00 is only permitted to be operated with battery unit 5AC901.BUPS-00! Information:...
Technical data Order number 5AC901.IUPS-00 Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 28 g Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark. The interface option is short-circuit proof.
Technical data 4.2.11.3 5AC901.IUPS-01 4.2.11.3.1 General information UPS IF option 5AC901.IUPS-01 used together with battery unit 5AC901.BUPS-01 allows the B&R industrial PC to be switched off properly without data loss during a power failure. This interface option can only be operated in slot IF option 1. Warning! UPS IF option 5AC901.IUPS-01 is only permitted to be operated with battery unit 5AC901.BUPS-01! Information:...
Page 190
Technical data Order number 5AC901.IUPS-01 Relative humidity Operation 5 to 90%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Weight Approx. 28 g Yes, although applies only if all components installed within the complete system have this certification and the complete system itself carries the corresponding mark.
Technical data 4.2.11.4 5AC901.BUPS-00 4.2.11.4.1 General information • Battery unit for UPS IF option 5AC901.IUPS-00 • Single-cell rechargeable battery • 2 Hawker Cyclon 12 V, 4.5 Ah rechargeable batteries connected in series • Rated voltage 24 V • Capacity 4.5 Ah The battery unit is subject to wear and should be replaced regularly (after the specified service life at the latest).
Page 192
Technical data Order number 5AC901.BUPS-00 Fuse Battery charging data Charging current Typ. 1 A Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature Operation -30 to 60°C Storage -65 to 80°C Transport -65 to 80°C Relative humidity Operation 5 to 95%, non-condensing Storage...
Technical data 4.2.11.4.5 5AC901.BUPS-00 - Dimensions 4.2.11.4.6 5AC901.BUPS-00 - Drilling template 4.2.11.4.7 Installation 4.2.11.4.8 Precautions for handling and use Spills and leaks: Further leakage must be prevented. Smaller spills must be bonded with dry sand, dirt and vermiculite. The use of flammable materials is not permitted.
Page 194
Technical data Handling and storage: • Store in cool, dry and well-ventilated rooms with impermeable surfaces and appropriate containment con- ditions in case of leakage. • Protect from adverse weather conditions and separate from incompatible materials during storage and transport. •...
Technical data 4.2.11.5 5AC901.BUPS-01 4.2.11.5.1 General information • Battery unit for UPS IF option 5AC901.IUPS-01 • Maintenance-free lead acid rechargeable battery • 2x 12 V, 2.2 Ah rechargeable batteries connected in series • Rated voltage 24 V • Capacity 2.2 Ah The battery unit is subject to wear and should be replaced regularly (after the specified service life at the latest).
Page 196
Technical data Order number 5AC901.BUPS-01 Capacity 2.2 Ah Fuse Battery charging data Charging current Typ. 0.88 A Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature Operation 0 to 40°C Storage -15 to 40°C Transport -15 to 40°C Relative humidity Operation 25 to 85%, non-condensing...
Page 197
Technical data 4.2.11.5.5 5AC901.BUPS-01 - Dimensions 21.6 ø11 4.2.11.5.6 5AC901.BUPS-01 - Drilling template 181.5 ø 11 107.5 4.2.11.5.7 Installation 4.2.11.5.8 Precautions for handling and use Spills and leaks: Further leakage must be prevented. Smaller spills must be bonded with dry sand, dirt and vermiculite. The use of flammable materials is not permitted.
Page 198
Technical data Handling and storage: • Store in cool, dry and well-ventilated rooms with impermeable surfaces and appropriate containment con- ditions in case of leakage. • Protect from adverse weather conditions and separate from incompatible materials during storage and transport. •...
Technical data 4.2.11.6 5CAUPS.xxxx-01 4.2.11.6.1 General information The UPS connection cable establishes the connection between the UPS interface option and battery unit. 4.2.11.6.2 Order data Order number Short description Figure Uninterruptible power supply 5CAUPS.0005-01 UPS cable - 0.5 m - For 5AC901.IUPS-xx 5CAUPS.0010-01 UPS cable - 1 m - For 5AC901.IUPS-xx 5CAUPS.0013-01...
Page 200
Technical data Information: The maximum length of the UPS connection cable depends on the following: • Power output • Voltage drop • Wire cross section • Sensor line 4.2.11.6.4 Installation Panel PC 900 (Skylake) User's manual V 1.10...
Technical data 4.2.12 Power supply 4.2.12.1 5AC902.PS00-00 4.2.12.1.1 General information This AC power supply for the Panel PC can optionally be expanded to allow operation with 100~240 VAC. 4.2.12.1.2 Order data Order number Short description Figure Power supply unit 5AC902.PS00-00 PPC900 power supply 85-264 VAC Required accessories Terminal blocks...
Installation and wiring 5 Installation and wiring 5.1 Installation and wiring 5.1.1 Basic information A damaged device has unpredictable properties and states. The unintentional installation or startup of a damaged device must be prevented. The damaged device must be marked as such and made inaccessible, or it must be returned for repairs immediately.
Installation and wiring • Ventilation openings are not permitted to be covered or blocked. • The device is only permitted to be operated in closed rooms and not permitted to be exposed to direct sunlight. • The climatic and ambient conditions must be taken into account – see "Environmental properties"...
Installation and wiring 24 VDC 0 VDC Installing cage clamp terminal block 0TB103.91 Insert a screwdriver into the cage clamp terminals ③ and secure the conductors with wire end sleeves ① in the terminal contacts ➁ as shown in the figure below. Close the terminal contact by removing the screwdriver. It is important to pay attention to the label on the spring clamp terminal ④.
Installation and wiring • Connect the device to the central grounding point (e.g. the control cabinet or the system) using the shortest possible low-resistance path. • Cable design with at least 2.5 mm² per connection. If a cable with wire end sleeve is used at terminal block 0TB103.9 or 0TB103.91, a cable with a maximum of 1.5 mm²...
Installation and wiring 5.1.3 Installing a Panel PC with an AP9x3 panel The with AP9x3 panel is installed in the installation cutout using retaining clips. The number of retaining clips depends on the panel. The device must be installed on a flat, clean and burr-free surface since tightening screws on an uneven area can result in damage to the display or the ingress of dust and water.
Installation and wiring 5.1.4 Installing the Automation Panel 1000 with retaining clips The with AP1000 panel is installed in the installation cutout using retaining clips. The number of retaining clips depends on the panel. The device must be installed on a flat, clean and burr-free surface since tightening screws on an uneven area can result in damage to the display or the ingress of dust and water.
Installation and wiring 5.1.5 Installing the Automation Panel 1000 with clamping blocks The with AP1000 panel is installed in the installation cutout using clamping blocks. The number of clamping blocks depends on the panel. The device must be installed on a flat, clean and burr-free surface since tightening screws on an uneven area can result in damage to the display or the ingress of dust and water.
Installation and wiring 5.1.6 Installation information for separate shipments Information: If the Panel PC 900 is not delivered as a complete system but as separate shipments, or if individual components are retrofitted, these components must be enabled in BIOS. To do this, launch BIOS during system startup, load the BIOS default values and save the settings.
Installation and wiring 5.1.7 Installing accessories 5.1.7.1 Replacing the CPU board and system unit 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. Information: If a bus unit is mounted on the Panel PC, it must be removed first.
Page 211
Installation and wiring 8. If the Panel PC 900 is converted to an Automation Panel, then the mounting plate must also be removed. To do so, remove the 5 Torx screws (T20) indicated below. 9. Remove the mounting plate from the display unit. 10.The mounting plate is installed by following these instructions in reverse;...
Installation and wiring 5.1.7.2 Installing or replacing the AC power supply 1. The on/off switch must be set to position "0" (off). Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2.
Page 213
Installation and wiring 8. To install an AC power supply on the Panel PC, it must be aligned parallel to the Panel PC. Plug the power supply connector into the female connector on the Panel PC. 9. Fasten the AC power supply with the 4 Torx screws (T20) (max. tightening torque 1.2 Nm). It is important that it is aligned parallel to the housing.
Installation and wiring 5.1.7.3 Replacing main memory Information: The Panel PC has 2 slots for main memory modules. Only the following B&R main memory modules are permitted: 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2.
Page 215
Installation and wiring Caution! If using only one main memory module, it must be installed in RAM slot 2. RAM slot 2 RAM slot 1 9. The cover plate can now be replaced by following these steps in reverse order. The maximum tightening torque of the Torx screws (T10) is 0.5 Nm.
Installation and wiring 5.1.7.4 Installing the interface option 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. Information: If a bus unit is mounted on the Panel PC, it must be removed first.
Page 217
Installation and wiring 5. Remove the cover plate by sliding it upwards and also remove the installed IF option. 6. Insert the interface option in the slot and fasten it to the Panel PC (max. tightening torque 0.5 Nm) with 2 Torx screws (T10).
Page 218
Installation and wiring 8. Secure the cover plate to the B&R Industrial PC using the same Torx screws (T10) from before. The Torx screws indicated by ➁ only need to be tightened if an IF option is mounted (max. tightening torque 0.5 Nm). 9.
Installation and wiring 5.1.7.5 Installing or replacing a slide-in compact drive Information: The slide-in compact drive can only be replaced without removing the PPC from the control cabinet if the wall is less than 5.5 mm thick. Steps 3, 4 and 11 are only necessary if the Panel PC is removed from the cabinet.
Installation and wiring 5.1.7.6 Replacing the fan kit 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3.
Installation and wiring 5.1.7.7 Replacing the fan filter 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3.
Installation and wiring 5.1.7.8 Installing the bus unit Information: Since the 5AC902.BX02-02 bus unit is supported beginning with firmware version V1.14, a firmware upgrade must be carried out before installation. See "Firmware upgrade" on page 291. 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2.
Page 223
Installation and wiring 7. Install the side cover on the bus expansion using the 4 indicated Torx screws (T10) (2 already removed, 2 included in delivery); the tightening torque is approx. 0.5 Nm. 8. The Panel PC can now be installed back in the control cabinet. Panel PC 900 (Skylake) User's manual V 1.10...
Installation and wiring 5.1.7.9 Installing PCI/PCIe cards 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3.
Installation and wiring 7. Install the PCI or PCIe card in the bus unit. Be sure to insert the PCI or PCIe card in the black guide rail at the top of the bus unit. Fasten the PCI or PCIe card using the indicated Torx screws (T10) removed earlier (max.
Installation and wiring 5.1.7.10 Installing a slide-in drive 1. Disconnect the power supply to the B&R Industrial PC (disconnect the power cable). Isolate the system from all potential sources of electrical power! 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3.
Page 227
Installation and wiring 7. Install the slide-in drive in the bus unit. Be sure to insert the slide-in drive in the black guide rails at the top and bottom of the bus unit. Slide-in drive guide rails Slot for slide-in drive 8.
Installation and wiring 5.1.7.11 Installing and connecting the UPS battery unit Warning! Opening the UPS battery unit is not permitted! 1. Disconnect the power supply cable to the B&R industrial PC. 2. Install the battery unit. For the drilling template, see the technical data for the respective UPS battery unit. The spacing between the battery unit and B&R industrial PC must be selected so that they can be connected together with the UPS cable;...
Commissioning 6 Commissioning 6.1 Switching on the device for the first time 6.1.1 General information before switching on the device Checklist Before the device is started up for the first time, the following points must be checked: • Have the installation instructions been observed as described in "Installation and wiring"...
Commissioning 6.2 Touch screen calibration B&R touch screen devices are equipped with a B&R touch controller that supports hardware calibration. These devices come already pre-calibrated from the factory. This feature offers great advantages especially for replace- ment parts since recalibration is usually no longer required when replacing a device (identical model/type). B&R still recommends recalibration for best results and to optimally adapt the touch screen to the needs of the user.
Commissioning 6.4 Configuring a SATA RAID volume with the internal RAID controller Depending on the chipset of the internal RAID controller, either the legacy or the UEFI BIOS boot can be used. 6.4.1 Legacy BIOS boot The following software description applies to the internal RAID controller on the QM77/QM170/HM170/CM236 chipset.
Commissioning The following keys can be used after entering BIOS Setup: Function Cursor ↑ Moves to the previous item. Cursor ↓ Go to next object. Enter Selects an item or opens a submenu. Returns to the previous menu. Ctrl+E Saves any changed settings and exits setup. Table 135: BIOS-relevant keys in the RAID Configuration Utility 6.4.1.1 Create RAID volume Figure 22: Configuration Utility - Create RAID volume (example)
Commissioning 6.4.1.2 Delete RAID volume Menu option "Delete RAID volume" can be used to format the RAID drive, making it non-RAID. The drive to be deleted is selected and then deleted by pressing <DEL>. Information: This option deletes all data on the drive, including the operating system. Figure 23: Configuration Utility - Delete RAID volume (example) 6.4.1.3 Reset disks to non-RAID An existing RAID volume can be deleted using option "Reset disks to non-RAID".
Commissioning 6.4.1.4 Recovery volume options Menu option "Recovery volume options" can be used to enable/disable recovery disk and master disk. Figure 25: Configuration Utility - Recovery volume options (example) Panel PC 900 (Skylake) User's manual V 1.10...
Commissioning 6.4.2 UEFI BIOS boot The following software description only applies to the internal RAID controller on the TS17 CPU modules. Information: B&R recommends using only drives of the same type in a SATA RAID volume (hard disk with hard disk in a set, SSD with SSD in a set;...
Commissioning After the BIOS has been configured for RAID in UEFI mode, menu "Intel(R) Rapid Storage Technology" is visible. Figure 28: Selecting option "Intel(R) Rapid Storage Technology" 6.4.2.1 RAID volume information Figure 29: Calling the information Panel PC 900 (Skylake) User's manual V 1.10...
Commissioning Figure 30: Selecting option "Delete" 6.4.2.2 Create RAID volume Creating a RAID group is done via menu "Create RAID volume". At least two of the available drives must be selected for this. Information: Executing this option will delete all data on the selected drives, including the operating system. Figure 31: Creating a new RAID volume Panel PC 900 (Skylake) User's manual V 1.10...
Commissioning Figure 32: Configuration of the new RAID volume Setting Explanation Configuration options Effect Name Option for entering the RAID name. Name with up to 16 characters Assigns a name to the RAID volume. RAID level Option for setting the RAID level. RAID0 (Stripes) Creates RAID0.
Commissioning Figure 33: Selecting option "Delete" Figure 34: Confirm 6.4.2.4 Reset disks to non-RAID An existing RAID volume can be deleted using menu "Reset to non-RAID". The RAID to be deleted is selected and then deleted by pressing <SPACE> (<ENTER> to confirm). Information: Deleting a RAID volume also deletes all of the data on the drive.
Page 240
Commissioning Figure 35: Selecting option "Reset" Panel PC 900 (Skylake) User's manual V 1.10...
Commissioning 6.5 Known problems/issues • When using a PCI or PCIe RAID controller, we recommend disabling ASPM or power management for the respective PCI or PCIe slot. • If problems occur with the ETH1 and ETH2 interface (connection aborted, slow data transfer, etc.), one possible solution is to disable the EEE feature (Energy Efficient Ethernet) in the driver.
Software 7 Software 7.1 BIOS options 7.1.1 General information BIOS is the abbreviation for "Basic Input and Output System". It is the basic standardized connection between user and system (hardware). The BIOS system used in this B&R industrial PC was developed by American Megatrends, Inc.
Software 7.1.2.1 BIOS Setup buttons The following keys are enabled during POST: Information: The key signals of the USB keyboard are only accepted after initializing the USB controller. Keys Function Del, F2 Access to the BIOS Setup menu. It is possible to boot from the network with F12. Opens the boot menu.
Software 7.1.3 BIOS TS17 Information: The following figures, BIOS menu options and descriptions refer to BIOS version 2.10. It is therefore possible that these figures or BIOS descriptions do not correspond to the installed BIOS version. In addition, the BIOS menu options depend on the system configuration. Information: BIOS default settings are bold and italicized in the tables.
Software 7.1.3.1 Main The BIOS Setup main menu appears immediately after key "Del" is pressed during system startup. 7.1.3.1.1 Platform information Path: Main > Platform Information Panel PC 900 (Skylake) User's manual V 1.10...
Software 7.1.3.2 Advanced 7.1.3.2.1 CPU configuration Information: The settings shown may vary depending on the CPU board being used. Path: Advanced > CPU configuration Panel PC 900 (Skylake) User's manual V 1.10...
Software 7.1.3.2.1.1 Processor information Information: The settings shown may vary depending on the CPU board being used. Path: Advanced > CPU configuration > Processor information 7.1.3.2.1.2 Power management control Path: Advanced > CPU configuration > Power management control Panel PC 900 (Skylake) User's manual V 1.10...
Page 248
Software 7.1.3.2.2 Thermal configuration Path: Advanced > Thermal configuration 7.1.3.2.2.1 CPU thermal configuration Path: Advanced > Thermal configuration > CPU thermal configuration Panel PC 900 (Skylake) User's manual V 1.10...
Page 250
Software 7.1.3.2.3.1 Display interface signal integrity settings Information: The following BIOS settings are system-optimized. Changes to these settings should only be made by system experts who are aware of the effects of the modification. Path: Advanced > IGD display configuration > Display interface signal integrity settings Panel PC 900 (Skylake) User's manual V 1.10...
Page 251
Software 7.1.3.2.4 OEM features Path: Advanced > OEM features Function of "Realtime environment" and "Hypervisor environment" settings: This function is supported in Automation Studio 4.7 and later. Starting with this version, it is possible to configure hypervisor operation with or without hyperthreading for the GPOS (if the CPU used supports this). Option Realtime environment (RTE) Hypervisor environment (HV)
Page 252
Software 7.1.3.2.4.2 Super I/O configuration Path: Advanced > OEM features > Super I/O configuration 7.1.3.2.4.3 CPU board features Path: Advanced > OEM features > CPU board features Panel PC 900 (Skylake) User's manual V 1.10...
Software Temperature values Path: Advanced > OEM features > CPU board features > Temperature values 7.1.3.2.4.4 System board features Path: Advanced > OEM features > System board features Panel PC 900 (Skylake) User's manual V 1.10...
Page 254
Software Statistical values Path: Advanced > OEM features > System board features > Statistical values Temperature values Path: Advanced > OEM features > System board features > Temperature values Panel PC 900 (Skylake) User's manual V 1.10...
Software Voltage values Path: Advanced > OEM features > System board features > Voltage values 7.1.3.2.4.5 Memory module features Path: Advanced > OEM features > Memory module features Panel PC 900 (Skylake) User's manual V 1.10...
Software 7.1.3.2.4.6 Display board features Path: Advanced > OEM features > Display link module features Statistical values Path: Advanced > OEM features > Display link module features > Statistical values Panel PC 900 (Skylake) User's manual V 1.10...
Page 257
Software Temperature values Path: Advanced > OEM features > Display link module features > Temperature values Panel #15 Path: Advanced > OEM features > Display board features > Panel #15 Panel PC 900 (Skylake) User's manual V 1.10...
Page 258
Software 7.1.3.2.4.7 Bus unit features Path: Advanced > OEM features > Bus unit features Statistical values Path: Advanced > OEM features > Bus unit features > Statistical values Panel PC 900 (Skylake) User's manual V 1.10...
Page 259
Software 7.1.3.2.4.8 IF option 1 features Path: Advanced > OEM features > IF option 1 features Statistical values Path: Advanced > OEM features > IF option 1 features > Statistical values Panel PC 900 (Skylake) User's manual V 1.10...
Page 260
Software 7.1.3.2.4.9 IF option 2 features Path: Advanced > OEM features > IF option 2 features Statistical values Path: Advanced > OEM features > IF option 2 features > Statistical values Panel PC 900 (Skylake) User's manual V 1.10...
Page 261
Software 7.1.3.2.4.10 Fan unit features Path: Advanced > OEM features > Fan unit features Statistical values Path: Advanced > OEM features > Fan unit features > Statistical values Panel PC 900 (Skylake) User's manual V 1.10...
Page 262
Software RPM values Path: Advanced > OEM features > Fan unit features > RPM values 7.1.3.2.4.11 Fan unit bus features Path: Advanced > OEM features > Fan unit bus features Panel PC 900 (Skylake) User's manual V 1.10...
Page 263
Software Statistical values Path: Advanced > OEM features > Fan unit bus features > Statistical values RPM values Path: Advanced > OEM features > Fan unit bus features > RPM values Panel PC 900 (Skylake) User's manual V 1.10...
Page 264
Software 7.1.3.2.4.12 Slide-in 1 features Path: Advanced > OEM features > Slide-in 1 features Temperature values Path: Advanced > OEM features > Slide-in 1 features > Temperature values Panel PC 900 (Skylake) User's manual V 1.10...
Page 265
Software 7.1.3.2.4.13 Panel control features Path: Advanced > OEM features > Panel control features Panel #x Path: Advanced > OEM features > Panel control features > Panel #X Panel PC 900 (Skylake) User's manual V 1.10...
Page 274
Software 7.1.3.3.1.1 Memory configuration Information: The following BIOS settings are system-optimized. Changes to these settings should only be made by system experts who are aware of the effects of the modification. Path: Chipset > Processor (integrated components) > Memory configuration Panel PC 900 (Skylake) User's manual V 1.10...
Software 7.1.3.3.1.3 DMI configuration Path: Chipset > Processor (integrated components) > DMI configuration 7.1.3.3.1.4 PEG port configuration Path: Chipset > Processor (integrated components) > PEG port configuration Panel PC 900 (Skylake) User's manual V 1.10...
Page 277
Software 7.1.3.3.1.5 Miscellaneous SA configuration Path: Chipset > Processor (integrated components) > Miscellaneous SA configuration 7.1.3.3.2 PCH-IO configuration Path: Chipset > PCH-IO configuration Panel PC 900 (Skylake) User's manual V 1.10...
Page 278
Software 7.1.3.3.2.1 PCI Express configuration Path: Chipset > PCH-IO configuration > PCIe configuration PCI Express Gen3 eq lanes Information: The following BIOS settings are system-optimized. Changes to these settings should only be made by system experts who are aware of the effects of the modification. Panel PC 900 (Skylake) User's manual V 1.10...
Page 280
Software 7.1.3.3.2.2 SATA configuration Path: Chipset > PCH-IO configuration > SATA configuration The following default settings must be observed: BIOS setting Explanation Configuration options Effect SATA mode selection Option for configuring supported serial AHCI The AHCI setting enables the inter- ATA connections.
Page 281
Software Software feature mask configuration Path: Chipset > PCH-IO configuration > SATA configuration > Software feature mask configuration 7.1.3.3.2.3 USB configuration Path: Chipset > USB configuration Panel PC 900 (Skylake) User's manual V 1.10...
Page 282
Software 7.1.3.3.2.4 Audio Path: Chipset > PCH-IO configuration > HD audio configuration HD audio advanced configuration Path: Chipset > PCH-IO configuration > HD audio configuration > Advanced configuration Panel PC 900 (Skylake) User's manual V 1.10...
Software 7.2 Upgrade information Warning! The BIOS and firmware on B&R devices must always be kept up to date. New versions can be down- loaded from the B&R website (www.br-automation.com). 7.2.1 BIOS upgrade An upgrade may be necessary for the following reason, for example: •...
Software 7.2.2 Firmware upgrade Caution! Do not switch off or reset the system during an upgrade under any circumstances!. A current firmware upgrade can be downloaded directly from the Downloads section of the B&R website (www.br- automation.com). 7.2.2.1 Procedure in Windows (ADI Control Center) 1.
Software 7.3 Operating systems 7.3.1 Windows 10 IoT Enterprise 2019 LTSC 7.3.1.1 General information Windows 10 IoT Enterprise 2019 LTSC is a special version of Windows 10 Enterprise for industrial use (Long-Term Servicing Channel) that provides a high level of protection for applications through additional lockdown functions. Information: For detailed information, see the user's manual of the operating system.
Software These are described in detail in the Windows 10 IoT Enterprise 2019 LTSC working guide. This contains infor- mation about installing languages, enabling lockdown and other features. Information: These settings, as well as all features not included in the LTSC version, result in different behavior compared to a standard Windows 10 Enterprise installation.
Software 7.3.1.7 Activation Windows 10 IoT Enterprise 2019 LTSC must be activated like its predecessor version. This takes place at B&R. The activation status can be checked in the Control Panel: The activation carried out by B&R is supported by special B&R extensions in the operating system and is not lost when the hardware is changed (e.g.
Software 7.3.2 B&R Linux 10 (GNU/Linux) 7.3.2.1 General information B&R supports Linux in the form of modified images based on Debian GNU / Linux 10 (codename "buster"). With B&R Linux, B&R offers a variant of Debian optimized for B&R industrial PCs that already includes all B&R- specific modifications and offers the broadest possible basis for various applications.
Software 7.4 Automation software 7.4.1 Licensing B&R Automation Runtime software components (e.g. Automation Runtime, B&R Hypervisor, mapp Technology) require a license. It is possible to choose between the following licensing types: Technology Guarding (TG) Technology Guarding is license protection used for individual software components. The Technology Guard (hard- ware dongle) serves as the license container;...
Software 7.4.4 Automation Runtime 7.4.4.1 General information The real-time operating system Automation Runtime is an integral part of Automation Studio. This real-time oper- ating system forms the software core for running applications on a target system. • Guarantees the highest possible performance of the hardware being used •...
Page 298
Software In addition, the maximum frequency of the GPU (Gfx) can be limited in BIOS under Advanced - Graphics config- uration using option Max. GPU frequency. Limiting the CPU and/or GPU frequency reduces power consumption and prevents the TDP from being exceeded. The optimal settings for real-time operation depend on several factors: 1) CPU variant being used: °...
Software 7.4.5 B&R Hypervisor B&R Hypervisor allows multiple operating systems to operate simultaneously on a single device. The operating systems can communicate with each other via a virtual network. Intelligent distribution of CPU resources B&R Hypervisor allows Windows or Linux to run simul- taneously with Automation Runtime.
Software 7.4.6 mapp Technology mapp is revolutionizing the creation of software for industrial machinery and equipment. mapp components – mapps for short – are as easy to use as smartphone apps. Rather than write lines and lines of code to build a user man- agement system, alarm system or motion control sequence from the ground up, developers of machine software simply configure the ready-made mapps with a few clicks of the mouse.
Software 7.5 Automation Device Interface (ADI) The Automation Device Interface (ADI) enables access to specific functions of B&R devices. 7.5.1 ADI driver 7.5.1.1 Installation The ADI driver is included in B&R Windows operating systems. The ADI driver (also includes the ADI Control Center) and user documentation can be downloaded at no cost from the Downloads section of the B&R website (www.br-automation.com).
Software 7.5.2 ADI Development Kit This software allows ADI functions to be accessed from Windows applications created with Microsoft Visual Studio, for example: Features: • Header files and import libraries • Help files • Example projects • ADI DLL: For testing applications if no ADI driver is installed. The appropriate ADI driver must be installed for the device.
Software 7.5.3 ADI .NET SDK This software allows ADI functions to be accessed from .NET applications created with Microsoft Visual Studio. Features: • ADI .NET class library • Help files (in English) • Sample projects and code snippets • ADI DLL: For testing applications if no ADI driver is installed. The appropriate ADI driver must be installed for the device.
Software 7.5.4 ADI OPC UA Server This document contains technical information about B&R Automation Device Interface OPC UA Server (B&R ADI OPC UA Server). The descriptions and figures refer to B&R ADI OPC UA Server V2.0.0 and later. ADI OPC UA Server provides the functions and information of the Automation Device Interface (ADI) as OPC UA variables.
Software 7.6 Key Editor A frequently occurring requirement for panels is adapting function keys and LEDs to the application software. With the Key Editor, individual adaptation to the application is possible quickly and easily. Features: • Configuration of normal keys like on a keyboard (A, B, C, etc.) •...
Software 7.7 KCF Editor The KCF Editor can be used as a simple alternative to the Key Editor. It can also be used to adapt function keys and LEDs to the application software. In contrast to the Key Editor, operation does not take place using a graphical representation of the device, but via a simple Windows dialog box.
Maintenance 8 Maintenance The following chapter describes the maintenance work that can be carried out by a qualified and trained end user. Information: Only components approved by B&R are permitted to be used for maintenance work. 8.1 General instructions for the temperature test procedure The purpose of these instructions is to explain the general procedure for application-specific temperature tests with B&R industrial PCs or Power Panels.
Maintenance If historical recording of the data is necessary, a separate application can be created. Information: To create a separate application, downloads such as the ADI .NET SDK are available from the B&R website (www.br-automation.com). 8.1.2.2 Evaluating with the BurnInTest tool from Passmark If a separate application is not created or used for temperature evaluation, B&R recommends using the BurnInTest software tool from PassMark.
Maintenance Figure 38: Test overview of a 2-slot PPC900 with DVD The respective test properties may need to be fine-tuned depending on the availability of a loopback plug and DVDs. If no USB loopback adapters are available, USB flash drives can also be used. These must be available in Windows as formatted drives.
Maintenance 8.2 Changing the battery Warning! The battery is only permitted to be replaced with a CR2477N battery. The use of any other battery may present a risk of fire or explosion. The battery can explode if handled improperly. Do not recharge, disassemble or dispose of the battery in fire.
Maintenance 8.3 Exchanging a CFast card Caution! Power must be turned off before exchanging CFast cards. The CFast card can be exchanged quickly and easily using the ejector (see image). Figure 41: Exchanging a CFast card Panel PC 900 (Skylake) User's manual V 1.10...
Maintenance 8.4 Cleaning Danger! In order to prevent unintentional operation (by touching the touch screen or keys), the device is only permitted to be cleaned when the power is switched off. • Use a cloth moistened with dishwashing detergent, screen cleaner or alcohol (ethanol) to clean the device. •...
Maintenance 8.6 Pixel errors Information: Displays can contain faulty pixels (pixel errors) due to the manufacturing process. They are not grounds for initiating a complaint or warranty claim. Panel PC 900 (Skylake) User's manual V 1.10...
Accessories 9 Accessories The following accessories have undergone functional testing by B&R in connection with the device used and can be operated with this device. Possible limitations regarding operation with individual components other than the complete system must be taken into account, however. All individual specifications of the components must be observed when operating the complete system.
Accessories Order number 0TB103.9 0TB103.91 Connection cross section AWG wire 26 to 14 AWG 26 to 12 AWG Wire end sleeves with plastic covering 0.20 to 1.50 mm² Solid wires 0.20 to 2.50 mm² Fine-stranded wires 0.20 to 1.50 mm² 0.20 to 2.50 mm²...
Page 316
Accessories Order number 0TB3103.8000 Tightening torque 0.5 to 0.6 Nm Electrical properties Nominal voltage 400 V Nominal current 20 A Table 153: 0TB3103.8000 - Technical data Yes, although applies only if all components installed within the complete system have this certification and the complete system itself carries the corresponding mark.
Accessories 9.2 Terminal block ready relay 9.2.1 0TB2104.8000 9.2.1.1 General information This 1-row, 4-pin TB2104 terminal block is used for ready relay 5AC901.IRDY-00. 9.2.1.2 Order data Order number Short description Figure Terminal blocks 0TB2104.8000 Connector 24 VDC - 4-pin female - Screw clamp terminal block 2.5 mm²...
Accessories 9.3 Replacement CMOS batteries 9.3.1 0AC201.91 / 4A0006.00-000 9.3.1.1 General information The lithium battery is needed to retain BIOS CMOS data and to back up the real-time clock (RTC). The battery is subject to wear and must be replaced if the battery capacity is insufficient (state "Bad"). 9.3.1.2 Order data Order number Short description...
Accessories 9.4 PCIe plug-in cards 9.4.1 5ACPCE.ETH1-00 9.4.1.1 General information This PCIe card has a 10/100/1000 Mbit/s network connection and can be used as an additional network interface in a standard PCI Express x1 slot. • PCIe x1 Ethernet card •...
Accessories Order number 5ACPCE.ETH1-00 General information B&R ID code DBF3 Diagnostics Data transfer Yes, using LED status indicators Certifications cULus E115267 Industrial control equipment Product family certification Interfaces Ethernet Quantity Controller Intel I210 Variant Shielded RJ45 Transfer rate 10/100/1000 Mbit/s Line length Max.
Accessories • Windows 7 • Windows 10 • B&R Linux Wake-on-LAN (WoL) and PXE boot are not supported. Information: Necessary drivers must be downloaded from the B&R website, not from manufacturer websites. 9.4.1.5 Dimensions 35.3 68.4 Figure 43: 5ACPCE.ETH1-00 - Dimensions Panel PC 900 (Skylake) User's manual V 1.10...
Accessories 9.4.2 5ACPCE.ETH4-00 9.4.2.1 General information This PCIe card has 4 10/100/1000 Mbit/s network connections and can be used as an additional network interface in a standard PCI Express x4 slot. • PCIe x4 Ethernet card • 4x Ethernet interface (10/100/1000 Mbit/s) 9.4.2.2 Order data Order number Short description...
Accessories Order number 5ACPCE.ETH4-00 Vibration Operation (continuous) 2 to 9 Hz: 1.75 mm amplitude / 9 to 200 Hz: 0.5 g Operation (occasional) 2 to 9 Hz: 3.5 mm amplitude / 9 to 200 Hz: 1 g Storage 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Transport 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Shock...
Accessories 9.5 CFast cards For detailed information about compatible CFast cards, see the aggregate data sheet for CFast cards on the B&R website. 9.6 Cables For additional information about compatible cables, see the B&R website (HMI cable manual). 9.7 USB mass storage device For additional information about compatible USB mass storage devices, see the B&R website (USB mass storage devices).
International and national certifications 10 International and national certifications 10.1 Directives and declarations 10.1.1 CE marking All directives applicable to the respective product and their harmonized EN standards are met. 10.1.2 EMC Directive The products meet the requirements of EU directive "Electromagnetic compatibility 2014/30/EU" and are designed for industrial applications: EN 61131-2:2007 Programmable controllers - Part 2: Equipment requirements and tests...
International and national certifications 10.2 Certifications Danger! A complete system can only receive certification if all individual components installed and connected in it have the corresponding certifications. If an individual component is used that does not have the corresponding certification, the complete system will also not be certified. B&R products and services comply with applicable standards.
International and national certifications 10.2.4 KC Products with this mark are tested by an accredited test laboratory and permitted to be introduced into the Korean market (based on EU conformity). 10.2.5 RCM Products with this mark are tested by an accredited test laboratory and certified by the ACMA.
International and national certifications 10.2.6.1.2 Mounting and installation PPC900 systems with AP923 or AP1000 display units are only permitted to be installed by knowledgeable and qualified personnel in accordance with the PPC900 and AP923 or AP1000 user's manuals. Devices must be in- stalled in a suitable protective housing that can only be opened by using a tool.
Page 330
International and national certifications Danger ! Le non-respect de ces instructions peut entraîner des blessures graves ou mortelles! 10.2.6.1.5 USB connection with the Automation Panel 1000 10.2.6.1.5.1 Introduction The information below describes the use of USB peripheral devices on the front USB interface of the B&R Automa- tion Panel 1000 in hazardous locations Class I, Division 2, Groups A, B, C and D.
Page 331
International and national certifications The unit concept allows the interconnection of nonincendive devices with connected devices with non-specifically tested combinations as a system. For this purpose, the permissible values of V (or U ) and I (or I ) for the connected device must be less than or equal to V ) and I ) for the nonincendive device, the permissible...
Environmentally friendly disposal 11 Environmentally friendly disposal All programmable logic controllers, operating and monitoring devices and uninterruptible power supplies from B&R are designed to have as little impact on the environment as possible. 11.1 Separation of materials To ensure that devices can be recycled in an environmentally friendly manner, it is necessary to separate out the different materials.
Appendix A Appendix A A.1 Maintenance Controller Extended (MTCX) The MTCX controller (FPGA processor) is located on the mainboard (part of every system unit) of the PPC900 device. The MTCX is responsible for the following monitoring and control functions: • Power on (power OK sequencing) and power failure logic •...
Appendix A A.A POWERLINK A.A.1 LED "S/E" (status/error LED) This LED is a green/red dual LED and indicates the state of the POWERLINK interface. The LED states have a different meaning depending on the operating mode of the POWERLINK interface. A.A.1.1 Ethernet mode In this mode, the interface is operated as an Ethernet interface.
Page 335
Appendix A LED "S/E" Green Description Single flash Mode: PRE_OPERATIONAL_1 (approx. 1 Hz) The interface is in mode PRE_OPERATIONAL_1. Managing node (MN) The MN is in "reduced cycle" mode. The CNs are configured in this mode. Cyclic communication is not yet taking place. Controlled node (CN) The CN can be configured by the MN in this mode.
Appendix A A.A.1.3 System stop error codes A system stop error can occur due to incorrect configuration or defective hardware. The error code is indicated by LED "S/E" blinking red. The blinking signal of the error code consists of 4 switch-on phases with short (150 ms) or long (600 ms) duration.
Appendix A A.B Cable data Signal Signal RS232 "RS232 - Bus length and cable type" on page 337 RS422 "RS422 - Bus length and cable type" on page 337 RS485 "RS485 - Bus length and cable type" on page 338 "CAN - Bus length and cable type"...
Appendix A A.B.3 RS485 - Bus length and cable type The maximum transfer rate of 115 kbit/s depends on the cable length and type of cable used. Bus length Transfer rate 1200 m Typ. 115 kbit/s Preferably, the cable material used should have the following properties or deviate only slightly from them in order to achieve an optimal transfer rate.
Appendix A A.D Viewing angles For viewing angle specifications (R, L, U, D) of the display types, see the technical data of the individual compo- nents. 6 o'clock direction Panel PC 900 (Skylake) User's manual V 1.10...
Appendix A A.E Chemical resistance All panels are made of a coated aluminum support frame. A.E.1 Autotex panel overlay (polyester) Unless otherwise specified, the panel overlay is resistant to the following chemicals, materials and substances per DIN 42115 Part 2 when exposed for up to 24 hours without visible changes: •...
Appendix A A.E.2 Aluminum panel overlay Unless otherwise specified, the panel overlay is resistant to the following chemicals, materials and substances per DIN 42115 Part 2 when exposed for up to 24 hours without visible changes: • Acetaldehyde • DRM/PM •...
Appendix A A.E.4 Touch screen 5-wire touch screen (single-touch) Unless otherwise specified, the touch screen is resistant to the following chemicals, materials and substances when exposed for up to 1 hour (at 25°C) with no visible changes: • Acetone • Antifreeze •...
Appendix A A.F Touch screen A.F.1 Touch screen (multi-touch generation 2) A.F.1.1 General information Valid for the following products: • 5AP933.156B-00 with Rev. ≤ C0 • 5AP933.185B-00 with Rev. ≤ C0 • 5AP933.215C-00 with Rev. ≤ C0 • 5AP933.240C-00 with Rev. ≤ C0 A.F.1.2 Technical data Information: The following specified characteristic data, features and limit values are only valid for these individual...
Appendix A A.F.2 Touch screen (multi-touch generation 3) A.F.2.1 General information Valid for the following products: A.F.2.2 Technical data Information: The following specified characteristic data, features and limit values are only valid for these individual components and may differ from those of the complete system. The data specified for the complete system applies to the complete system in which this individual component is used, for example.
Appendix A A.F.3 5-wire touch screen (single-touch) A.F.3.1 Technical data Information: The following specified characteristic data, features and limit values are only valid for these individual components and may differ from those of the complete system. The data specified for the complete system applies to the complete system in which this individual component is used, for example.
Appendix A A.G Installation compatibility This section describes the compatibility of the installation dimensions for Power Panel 100/200, Power Panel 300/400, Power Panel 500, Automation Panel 900, Automation Panel 1000, Panel PC 700 and Panel PC 800 devices depending on the respective device diagonals. The external dimensions of the device types of the respective diagonals are identical.
Page 347
Appendix A Diagonal Format PP100/200 PP300/400 PP500 AP900 AP1000 PPC700 PPC800 Outer dimen- 435 x 330 sions Land- scape1 Installation 415 x 312 415 x 313 415 x 312 415 x 313 415 x 312 dimensions 15" Outer dimen- 435 x 430 435 x 430 sions Por-...
Appendix A A.G.2 Compatibility details A.G.2.1 Example The dimensions (mm) in the subsequent figures have the following meaning. G H I Diagram legend Spacing (left) to device edge Difference value Outer dimensions Installation dimensions/Cutout for PP100/200/300/400 device Spacing (right) to device edge Installation dimensions/Cutout AP900/PP500/PPC700 device Spacing (top) to device edge Outer contour of device...
Page 349
Appendix A Installation compatibility - 5.7" devices - Portrait1 212 x 245 PP100/200/300/400 AP1000 199 x 226.8 199 x 232 PP500 11.7 PP100/200/300/400 6.5 PP500, AP1000 Outer contour of device Cutout for PP100/200/300/400 device Cutout for PP500/AP1000 device The 5.7" Automation Panel 1000 and Power Panel 500 are not 100% compatible with Power Panel 300/400 and Power Panel 100/200 devices in Portrait1 format.
Appendix A A.G.2.3 10.4" devices The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm. The cutout tolerance for the AP1000 is +0 mm / -0.5 mm. Installation compatibility - 10.4" devices - Landscape1 323 x 260 PP100/200/300/400 PP500 AP900/PPC700...
Page 351
Appendix A Installation compatibility - 10.4" devices - Portrait1 323 x 358 PP100/200/300/400 AP900/PPC700 303 x 336 303 x 341 PP500 AP1000 13.5 PP100/200/300/400 8.5 AP900, AP1000, PPC700, PP500 Outer contour of device Cutout for PP100/200/300/400 device Cutout for AP900/AP1000/PPC700/PP500 device Figure 45: Installation compatibility - 10.4"...
Appendix A A.G.2.4 12.1" devices The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm. The cutout tolerance for the AP1000 is +0 mm / -0.5 mm. Installation compatibility - 12.1" devices - Landscape1 10 AP900, PPC700, PP500, AP1000 10 AP900, PPC700, PP500, AP1000 8.5 PP100/200/300/400 8.5 PP100/200/300/400...
Appendix A A.G.2.5 15" devices The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm. The cutout tolerance for the AP1000 is +0 mm / -0.5 mm. Installation compatibility - 15" devices - Landscape1 435 x 330 8.5 PP500, AP1000 PP100/200/300/400, AP900, PPC700, PPC800 AP900/PPC700...
Appendix A A.G.2.6 17" devices The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm. The cutout tolerance for the AP1000 is +0 mm / -0.5 mm. Installation compatibility - 17" devices - Landscape1 477 x 390 460 x 373 AP900/PPC700 Outer contour of device...
Appendix A A.G.2.8 21.3" devices The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm. The cutout tolerance for the AP1000 is +0 mm / -0.5 mm. Installation compatibility - 21.3" devices - Landscape1 583 x 464 566 x 447 AP900 Outer contour of device...
Need help?
Do you have a question about the Multi-Touch 900 and is the answer not in the manual?
Questions and answers