B&R Automation Panel 1000 User Manual page 162

Table of Contents

Advertisement

Accessories
9.4.5.1.6 Cable pinout
If you wish to assemble a suitable cable yourself, the cable must be wired according to this pinout.
Information:
Functionality is only guaranteed for the cables available from B&R.
Cable shield
Pin
Pinout
1
TMDS data 2 negative
2
TMDS data 2 positive
3
Shielding TMDS data 2 and SDL
4
SDL negative
5
SDL positive
6
DDC data
7
DDC clock
8
Not connected
9
TMDS data 1 negative
10
TMDS data 1 positive
11
TMDS data 1 and XUSB0 shield
12
XUSB0 negative
9.4.5.1.7 Cable connection
The SDL flex cable with extender must be connected in the correct direction between the B&R industrial PC and
Automation Panel. For this purpose, the signal direction is indicated on the extender unit.
Figure 90: Example for the signal direction of the SDL flex cable with extender
162
DVI (24+1), male
Figure 89: 5CASDL.0xx0-13 - Pinout
Extender unit
Pin
Pinout
13
XUSB0 positive
14
+5 V
15
GND
16
Hot plug detection
17
TMDS data 0 negative
18
TMDS data 0 positive
19
Shielding TMDS data 0 and XUSB1
20
XUSB1 negative
21
XUSB1 positive
22
TMDS data shield
23
TMDS clock positive
24
TMDS clock negative
DVI (24+1), male
Cable shield
B&R industrial PC
Automation Panel 1000 user's manual V2.00

Hide quick links:

Advertisement

Table of Contents
loading