Appendix A
The 5.7" Power Panel 500, Power Panel 300/400 and Power Panel 100/200 devices in Landscape2 format are
100% compatible.
The 5.7" Automation Panel 1000 and Power Panel 500 are not 100% compatible with Power Panel 300/400 and
Power Panel 100/200 devices in Portrait1 format. Automation Panel 1000 and Power Panel 500 devices need a
cutout that is 5.2 mm larger (bottom edge).
The larger cutout can be used conditionally for all devices:
• During installation, it is important to ensure that the PP100/200 and PP300/400 devices are positioned and
installed as centrally as possible in the cutout. If this is not the case, the retaining clips can no longer grip
and impermeability is no longer ensured by the circumferential cord gasket (IP65).
196
6.5
PP100/200/300/400
PP500
Figure 104: Installation compatibility - 5.7" devices - Landscape2
6.5
PP100/200/300/400
PP500
Outer contour of device
Cutout for PP100/200/300/400 device
Cutout for PP500/AP1000 device
Figure 105: Installation compatibility - 5.7" devices - Portrait1
302 x 187
289 x 174
Outer contour of device
Cutout for device
212 x 245
6.5
6.5
199 x 226.8
199 x 232
11.7 PP100/200/300/400
6.5 PP500, AP1000