B&R Automation Panel 1000 User Manual page 44

Table of Contents

Advertisement

Technical data
4.1.5.1.7 USB In interface
The USB In interface is a USB 2.0 type B interface that is used to transfer USB data. It must be connected to a USB
interface on the output device (e.g. B&R industrial PC) if DVI operation or SDL operation with a USB type A/B cable
was chosen as the transfer method. For possible transfer methods, see section
If the interface is connected to an output device (e.g. B&R industrial PC), then USB 2.0 transfer rates are possible
on the USB1 and USB2 interfaces.
Standard
Variant
Transfer rate
Current-carrying capacity
1)
Cable length
1)
The USB interfaces are protected by a maintenance-free "USB current-limiting switch" (max. 500 mA).
4.1.5.1.8 Brightness controls
The brightness controls can be used to set the brightness of the backlight
on the Automation Panel in DVI operation. Buttons have no function during
SDL operation; the brightness can be set via the B&R Control Center, for
example.
44
Description
USB 2.0
Type B, female
Low speed (1.5 Mbit/s)
Full speed (12 Mbit/s)
High speed (480 Mbit/s)
Max. 500 mA
Max. 5 m (without hub)
-
"Connection options" on page
Figure
Automation Panel 1000 user's manual V2.00
17.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents