9.4.6 SDL3/SDL4 cables

9.4.6.1 5CASD3.xxxx-00

9.4.6.1.1 General information
5CASD3.xxxx-00 SDL3/SDL4 cables are designed to transfer SDL3/SDL4 data and enable easy cable installation.
Due to the RJ45 connector, the cable is also suitable for narrow feed-throughs, e.g. in swing arm shafts.
Caution!
The cable is only permitted to be connected/disconnected when the power is switched off.
9.4.6.1.2 Order data
Model number
Short description
SDL3/SDL4/PoE cables
5CASD3.0030-00
SDL3/SDL4 cable - 3 m
5CASD3.0050-00
SDL3/SDL4 cable - 5 m
5CASD3.0100-00
SDL3/SDL4 cable - 10 m
5CASD3.0150-00
SDL3/SDL4 cable - 15 m
5CASD3.0200-00
SDL3/SDL4 cable - 20 m
5CASD3.0300-00
SDL3/SDL4 cable - 30 m
5CASD3.0500-00
SDL3/SDL4 cable - 50 m
5CASD3.1000-00
SDL3/SDL4 cable - 100 m
Table 66: 5CASD3.0030-00, 5CASD3.0050-00, 5CASD3.0100-00, 5CASD3.0150-00,
5CASD3.0200-00, 5CASD3.0300-00, 5CASD3.0500-00, 5CASD3.1000-00 - Order data
9.4.6.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
General information
Certifications
CE
EAC
UL
HazLoc
Cable construction
Wire cross section
Properties
Outer jacket
Material
Color
Labeling
Lines
Wire insulation
Wire colors
Shield
Type
Connector
Type
Mating cycles
Contacts
Electrical properties
2)
Operating voltage
Conductor resistance
Wave impedance
Table 67: 5CASD3.0030-00, 5CASD3.0050-00, 5CASD3.0100-00, 5CASD3.0150-00,
5CASD3.0200-00, 5CASD3.0300-00, 5CASD3.0500-00, 5CASD3.1000-00 - Technical data
Automation Panel 1000 user's manual V2.00
5CASD3.
5CASD3.
5CASD3.
0030-00
0050-00
0100-00
4x 2x 26/7 AWG
HARTING INDUSTRIAL CABLE S/FTP CAT 6A PUR 4x2xAWG26/7
Green/White-green, orange/white-orange, blue/white-blue, brown/white-brown
Aluminum foil and braided wire shield composed of tinned copper wires
Bare copper strand, 4x 2x 26/7 AWG
≤100 V
≤290 Ω/km
5CASD3.
5CASD3.
0150-00
0200-00
Yes
Yes
cULus E115267
Industrial control equipment
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
Flame-retardant, halogen-free, lead-free
Polyurethane (PUR)
Yellow, RAL 1021
Polyethylene (PE)
2x RJ45, male
Min. 750
8
100 ±5 Ω (at 100 MHz)
Accessories
Figure
5CASD3.
5CASD3.
5CASD3.
0300-00
0500-00
1000-00
1)
4x 2x 23/1 AWG
HARTING INDUSTRIAL INSTALLATION
CABLE S/FTP CAT 7 PUR 4x2xAWG23/1
Bare copper strand, 4x 2x 23/1 AWG
≤125 V
≤75 Ω/km
163