Defining Adhesive Tracking System Alarms - Nordson ProBlue Flex User Manual

Adhesive melter with an original equipment manufacturer (oem) user interface
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

58
ProBlue Flex OEM User's Guide
SETUP TOOL
Please select how to load a configuration file
LOAD FROM USB/COMPUTER
USE PREVIOUS FILE
CREATE NEW
SYSTEM SETTINGS
FLOW
Setting
Alert
Low Alert Threshold
High Alert Threshold
Alert Delay Count
Stop Alarm
Part 1129255_01

Defining Adhesive Tracking System Alarms

Use the Teach mode to automatically calculate the Target Add-On and
Products to Average values.
1. Log into your BBconn Cloud account, then do the following:
S
Select SETUP TOOL - create or load a .NOR file.
S
Select SYSTEM SETTINGS | FLOW.
2. From the Monitor Alarm Settings section, enter the following
information. When done, select SAVE.
Description
Enables or disables the system from
monitoring and generating flow Alert
alarms
Note: When an Alert alarm is
generated, production continues, but
attention may be needed.
How much lower the add-on weight
(mg) can be from the Target Add-On
value before an Alert alarm is
generated.
How much higher the add-on weight
(mg) can be from the Target Add-On
value before an Alert alarm is
generated.
The number of consecutive
out-of-tolerance products allowed
before the system considers them
defective and generates an Alert
alarm.
Enables or disables the system from
monitoring and generating flow Stop
alarms.
Note: When a Stop alarm is
generated, production is halted.
Immediate attention is required.
Default
Min
Disabled
N/A
.2 * Target
.05 *
add on
Target
value
add on
value
.3 * Target
.05 *
add on
Target
value
add on
value
4
1
Disabled
N/A
E 2020 Nordson Corporation
Max
N/A
.5 * Target
add on
value
.5 * Target
add on
value
15
N/A

Hide quick links:

Advertisement

Table of Contents
loading