Electronic Pressure Adjust Alarms

Alarm
Short Description
Type
Alert
High Pressure Alert
Alert
Low Pressure Alert
Pressure below detectable
Alert
range
Pressure Control Valve
Alert
Disconnected
Pressure Sensor
Alert
Disconnected
Alert
Minimum System Pressure
Fault
Alert
Maximum System Pressure
Fault
Part 1129255_01
The following table details the troubleshooting tips to resolve Alert and Fault
conditions.
Pressure exceeds the High
Pressure Threshold.
Pressure is below Low
Pressure Threshold.
Pressure input indicates the
pressure is below the
sensing range.
No pressure adjust device is
detected, and is required for
run-up or remote pressure
adjustments.
The system has detected
that the air pressure sensor
is disconnected from the
Low Voltage Control Board.
System pressure is below
the minimum required
system pressure.
System pressure is above
the maximum required
system pressure.
Details
Troubleshooting Tips
Check or do the following:
S
S
S
Check air supply air input for
leaking airline.
Check air supply to the
system for disconnected air
input or leaking airline.
Install or reconnect pressure
adjust device.
Reconnect sensor.
Increase input air pressure.
Reduce input air pressure.
Increase pressure
threshold.
Check supply air
pressure.
Check for defective
transducer.