Manually Adjusting System Air Pressure

E 2020 Nordson Corporation
You can manually adjust the system pressure using a 6mm Hex wrench. Use
the gauge to help define the system air pressure you want.
S
Using a 6mm Hex wrench, turn clockwise to increase pressure and
counterclockwise to decrease pressure to best suit your production
requirements.
Optional pressure gauge
Manual pressure adjustment
ProBlue Flex OEM User's Guide
Picture shown with optional Fill System
29