32
ProBlue Flex OEM User's Guide
Part 1129255_01
6. Select Low Pressure Alert Threshold, then enter the amount of
pressure offset below the set point before the melter enters into an Alert
condition.
Pressure
Default
PSI
(-)10 from
set point
(-)0.69 from
BAR
set point
kPa
(-)69 from
set point
7. Select High Pressure Alert Threshold, then enter the amount of
pressure offset above the set point before the melter enters into an Alert
condition.
Pressure
Default
PSI
(+)10 from
set point
(+)0.69
BAR
from set
point
kPa
(+)69 from
set point
8. When done, press SAVE.
NOTES:
S
The "+" symbol appears next to the High Pressure Alert threshold setting
indicating the offset or delta from the Maximum Pressure Set Point Range
setting.
S
The "-" symbol appears next to the Low Pressure Alert threshold setting
indicating the offset or delta from the Minimum Pressure Set Point Range
setting.
Minimum
Maximum
(-)5 from
(-)70 from
set point
set point
(-)0.34 from
(-)4.83 from
set point
set point
(-)34 from
(-) 483from
set point
set point
Minimum
Maximum
(+)5 from
(+)70 from
set point
set point
(+)0.34
(+)4.83
from set
from set
point
point
(+)34 from
(+)483 from
set point
set point
E 2020 Nordson Corporation