62
ProBlue Flex OEM User's Guide
LED
DS1
24V Enable for external devices
DS2
CPU Reset
DS3
3.3V Supply Status
DS4
Sensor quadrature status. Indicates the
quadrature relationship between the two flow
meter sensors.
DS5
Flowmeter Sensor B Status
DS6
Flowmeter Sensor A Status
DS7
General Status LED
DS8
24VDC Input
DS9
Trigger 2 State
DS10
Trigger 1 State
DS11
Encoder quadrature status. Indicates the
quadrature relationship between the two
encoder inputs or the state of a single phase
encoder input.
DS12
Ejector State
Part 1129255_01
Description
Color
S
Green: Enabled
S
Amber: enabled with overload condition
S
Red: Disabled with no load connected
S
Off: Disabled
S
Off: Normal operation
S
Red: CPU reset in progress
S
Green: Normal operation
S
Amber or Red: Fault in 3.3V regulator
S
Off: Missing 24VDC
Cycles between off, green, amber, and red
S
Green: Flow detected
S
Amber: Sensor connected, but no flow
detected
S
Red: Sensor failure or not connected
S
Green: Flow detected
S
Amber: Sensor connected, but no flow
detected
S
Red: Sensor failure or not connected
Indicates the overall status of the Flow PCA
S
Green: 24VDC present
S
Red: 24VDC connected backwards
S
Green: Trigger #2 is being driven
S
Off: Trigger #2 is not being driven
S
Green: Trigger #1 is being driven
S
Off: Trigger #1 is not being driven
For quadrature encoders will cycle between off,
green, amber, and red. For single phase
encoders will toggle between off and green.
S
Amber: Ejector active
S
Off: Ejector inactive