ProBlue Flex OEM User's Guide
Problem
3.
Under limit alarm (Alarm
Lower Limit)
4.
System not displaying
or generating alarms
5.
Add-On/Product value
erratic or 0
6.
System stuck in Teach
mode
Part 1129255_01
General and Flow Control Alarms
Possible Cause
Failed solenoid, module, or nozzle
Operator changed setting:
temperature, pump air pressure,
adhesive pattern, line speed,
carton size, or an ATS setting
Alert and or Stop Alarms are
disabled.
Enabled Output or Alarm Output
wiring loose or disconnected
Product detector out of calibration
Flow meter sensor loose
No products passing the product
detector when the system is in Skip
mode, or the system is in Teach
mode and Products to Skip is
zero (0)
(contd)
Corrective Action
Refer to the applicator manual to
troubleshoot applicator problems.
Repair or replace failed components
as needed.
Re-teach the ATS system for the
current settings.
Enable the Alert and Stop Alarms.
Check and correct the wiring.
Adjust the gain to ensure that the
product detector is triggered during
the complete carton cycle.
Check the flow meter sensors on the
manifold and re-tighten loose sensors
to hand-tight.
Press the CLEAR ALARM key to exit
the skip or Teach modes.