a
E 2020 Nordson Corporation
Draining or Purging the Melter
Use the Drain feature to remove adhesive from the tank. The melter must be
in a Ready State.
1. Using a 4mm Hex driver, remove the front panel (a).
2. Extend the drain pathway (b), and use a large enough pan to collect the
adhesive from the tank.
b
1. Make sure all the following preconditions are met:
S
Wear safety gloves and body protection.
S
Have a pan to collect the adhesive.
S
The melter must be at Temperature Ready.
S
The Master Pump Control must be On.
S
For non-electronic pressure adjust systems, you must manually lower
the hydraulic pressure BEFORE draining.
NOTES:
S
You can manually activate each applicator solenoid to drain adhesive
from the hoses and applicators. Make sure to wear safety gloves and
have a pan to collect the adhesive.
S
If you have a fill system and if the master Fill was switched On, then it is
automatically disabled while Drain is active. You must use the Fill Master
Control to switch it back On.
ProBlue Flex OEM User's Guide
103
Part 1129255_01