56
ProBlue Flex OEM User's Guide
Setting
Product Skip
Number of products to ignore before teaching or
Count
monitoring products for out-of-tolerance adhesive
output
Products to
The number of products the system averages to
Average
calculate the Target Add-on value
Notes:
S
The Products to Average value is automatically
determined and set during the Teach process.
S
If you do not use the Teach mode, make sure
the number of products meets or exceeds a
total weight of 8 grams.
S
If you make use of the Teach option, any value
you enter will be overwritten.
S
Use a smaller value if you want a faster time to
alarm for out-of-tolerance products.
Idle Skip Time
The amount of time (in seconds) the system waits
to start skipping products when a product is not
detected for the specified amount of time.
Note:
S
This feature is needed for operations in which
the production line is cleared out after being
stopped and/or before being restarted.
Startup Skip
The additional number of products to skip at start
Count
up before teach mode starts.
Note:
At start up (power on) and when idle skip time is
exceeded, the Startup Skip Count is added to the
products to skip. Under these conditions, the
number of products to skip and Startup Skip Count
must be met before a Teach operation begins.
Part 1129255_01
Description
Default
Minimum
Maximum
10
0
255
10
1
1000
10 Sec
1
255
50
0
1000
E 2020 Nordson Corporation