8
ProBlue Flex OEM User's Guide
Part 1129255_01
Disabling the Applicators
NOTE: Adhesive dispensing applicators are referred to as "guns" in some
previous publications.
All electrical or mechanical devices that provide an activation signal to the
applicators, applicator solenoid valve(s), or the melter pump must be
disabled before work can be performed on or around an applicator that is
connected to a pressurized system.
1. Turn off or disconnect the applicator triggering device (pattern controller,
timer, PLC, etc.).
2. Disconnect the input signal wiring to the applicator solenoid valve(s).
3. Reduce the air pressure to the applicator solenoid valve(s) to zero (0);
then relieve the residual air pressure between the regulator and the
applicator.
General Safety Warnings and Cautions
Table 1 contains the general safety warnings and cautions that apply to
Nordson hot melt and cold adhesive equipment. Review the table and
carefully read all of the warnings or cautions that apply to the type of
equipment described in this manual.
Equipment types are designated in Table 1 as follows:
HM = Hot melt (melters, hoses, applicators, etc.)
PC = Process control
CA = Cold adhesive (dispensing pumps, pressurized container, and
applicators)
E 2020 Nordson Corporation