Technical Data Dependent Upon The Power - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data
10.1 Technical data of the G115D converter with SIMOGEAR geared motor
Property
PROFIsafe
Encoder interface
EM brake
USB interface
Memory card (optional) Slot for SD memory cards
10.1.3

Technical data dependent upon the power

Frame size
FSA
FSB
Typical current consumption on 24 V DC power supply
G115D motor-mounted converter
Communications
PROFINET
The current consumption does not include the consumption of connected sensors at the digital
1)
inputs (maximum 200 mA in total) and the connected sensors at the digital outputs (maximum
500 mA in total).
334
Explanation
2 (DI 0 & DI 1)
Mini-USB
Memory cards (Page 281)
Rated power (kW)
0.37
0.55
0.75
1.1
1.5
2.2
3
4
Frame size
FSA/FSB
Yes
Via 2 digital inputs (DI 0 and DI 1)
HTL, 2-track (A/B)
Power supply: 18 V DC to 30 V DC
Maximum input frequency: 200 kHz
Maximum current consumption: 100 mA
180 V DC
Rated current: 0.8 A
Disconnection on the DC side permits "fast" braking
Input current (A)
1.08
1.47
1.79
2.43
3.18
4.65
6.23
8.16
Typical current consumption
(from the 24 V DC supply, external
24 V DC ± 15 %)
290 mA
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
Power loss (W)
20.22
24.43
28.52
37.47
49.02
64.35
85.89
114.53
1)
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading