Replacing The Coil Fuse (Section/Curve Module) - Bosch Rexroth ActiveMover Assembly Instructions Manual

Linear motor system
Hide thumbs Also See for Rexroth ActiveMover:
Table of Contents

Advertisement

140/172 Maintenance and servicing
Please note:
The coil fuses for the
section/curve modules are
located on the left and right
power supply PCBs.
Required spare parts
• 15 A section/curve module
coil fuse
3 842 555 986
1.
Open the protective
panel on the electronic
box on the section
module/remove the
protective cover from the
curve module.
2.
Pull the coil fuse out of
the fuse holder.
3.
Install the new (15 A)
coil fuse in reverse
order.
Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07

10.4.22 Replacing the coil fuse (section/curve module)

1
2
3
Fig. 100:
Replacing the coil fuse (section/curve module)
1
2
3
557 186-100

Advertisement

Table of Contents
loading

Table of Contents