138/172 Maintenance and servicing
Required spare parts
• Drive thermistor
3 842 555 971
1.
Open the protective
panel on the electronic
box on the section
module/remove the
protective cover from
the curve module.
2.
Disconnect the
thermistor cable plug
connector from the
power supply PCB.
3.
Remove the thermistor
from the thermistor
mounting.
4.
Install the new
thermistor in reverse
order.
Please note:
The thermistor needs to be
pushed all the way into the
thermistor mounting.
Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07
10.4.20 Replacing drive thermistors
1
2
3
4
Fig. 98:
Replacing drive thermistor
1
2
3
4
557 186-98