Installing And Aligning The Calibration Set (Optional) - Bosch Rexroth ActiveMover Assembly Instructions Manual

Linear motor system
Hide thumbs Also See for Rexroth ActiveMover:
Table of Contents

Advertisement

148/172 Maintenance and servicing
Please note:
• The calibration set is
required to adjust/calibrate
the measuring system on
the WT.
• Improper use of the
calibration set can
damage the WT and
ActiveMover.
• Remove the calibration set
before start-up.
A:
Position indicator
B:
Fixing element
C:
Aligning block
D:
Knurled thumbscrew
E:
Reference system
F:
Knurled thumbscrew
1.
Set the fixing element
(B) in the groove behind
the sensor unit on a
section module.
The side marked "D"
should be facing the
sensor unit.
2.
Center the fixing element
on an odd-numbered
encoder (see also
Section 10.5.3).
3.
To press the mount back
and align it as parallel
to the V-rail as possible,
insert suitable shims
between the fixing
element and the sensor
unit.
Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07
10.5.4

Installing and aligning the calibration set (optional)

3
Fig. 108:
Installing measuring system adjusting tool (1)
D
E
1
2x
SW
B
1
2
3
A
B
C
F
557 186-108

Advertisement

Table of Contents
loading