144/172 Maintenance and servicing
Required tool
• 0.2–0.8 mm plastic feeler
gauge
Please note:
Before adjusting, check the
following:
• Guide rollers per Table 7
on page 112
• Measuring system per
Table 7 on page 112
• Proper installation of the
measuring system
(see Section 10.4.5)
1.
Check the spacing (X)
between measuring
system and sensor unit.
Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07

10.5 Adjustment and calibration

10.5.1

Checking and adjusting measuring system distance

!
Fig. 104:
Checking measuring system distance
!
557 186-104