Please note:
Due to thermal expansion
during operation, the
modules should always have
a min. spacing of 0.5 mm
from each other.
This spacing should never be
less than 0.5 mm.
Required tool
• 0.5 mm plastic feeler gauge
11.
Make sure all modules
have a min. spacing of
0.5 mm from each other.
12.
Tighten the upper
connection plate.
13.
Tighten the side
connection plates
(on both sides).
Add all other system
sections in the same
fashion.
13
12x
SW8
M
=80 Nm
D
Fig. 44:
Connecting system sections (2)
3 842 559 521/2018-07, MIT: ActiveMover, Bosch Rexroth AG
Assembly
67/172
!
11
X = 0,5 mm
!
11
X = 0,5 mm
12
8x
SW8
M
=80 Nm
D
557 186-44