Please note:
• To give a better view
of the terminals, the
curve module is shown
here without coil and
measuring system.
• See the circuit diagram
included in the scope
of delivery for more
information on electrical
connections.
1.
Remove the top curve
module cover.
2.
Insert the power supply
cable into the curve
module from below.
3.
Connect the power
cable (28 V DC, blue) to
Terminal A.
4.
Connect the power cable
(0 V, blue/white) to
Terminal B.
7.6.12
Connecting power supply in the curve module
A
A
Fig. 70:
Connecting power supply in the curve module
B
3 842 559 521/2018-07, MIT: ActiveMover, Bosch Rexroth AG
Assembly
95/172
B
557 186-70