Diagnostic Leds; Activemover Controller; Power Supply Pcb - Bosch Rexroth ActiveMover Assembly Instructions Manual

Linear motor system
Hide thumbs Also See for Rexroth ActiveMover:
Table of Contents

Advertisement

164/172 Troubleshooting
Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07

11.4 Diagnostic LEDs

11.4.1

ActiveMover controller

(in control cabinet)
LED
Color
Status
Power Green
ON
Flashing
Red
ON
Flashing
Red/
Flashing
green
HDD
Yellow
Intermittent
flashing
Link
Yellow
ON
Flashing
OFF
Run
Green
ON
Flashing
Red
ON
Flashing
11.4.2

Power supply PCB

(in the section/curve module electronic box)
LED color
Status
Green
ON
OFF
Red
ON
OFF
Normal status
SDL display
connected
No SDL display
connected
Normal status
Possible fault/error
Power supply off
• Turn power supply on.
A/D CPLD (complex programmable logic
device) not programmed
• Contact Customer Service.
Possible fault/error
Controller hardware fault
• Contact Customer Service.
Controller off
• Turn controller on.
Controller hardware fault
• Contact Customer Service.
SDL display power supply interrupted
• Check power cables.
Controller start sequence still
running
• Wait a few minutes.
Controller software error
• Contact Customer Service.