Connecting Network And Control Voltage Cables (24 V) (From Left Section/Curve Module) - Bosch Rexroth ActiveMover Assembly Instructions Manual

Linear motor system
Hide thumbs Also See for Rexroth ActiveMover:
Table of Contents

Advertisement

Please note:
• Connecting to an adjacent
curve module is the
same as connecting to an
adjacent section module.
• See the circuit diagram
included in the scope
of delivery for more
information on electrical
connections.
• The control voltage cable
(24 V) can be connected
to either contact on
Terminal G.
1.
Connect the network
cable to Terminal H on
the PCB (gateway).
2.
Connect the control
voltage cable (24 V) to
Terminal G.
7.6.6
Connecting network and control voltage cables (24 V)
(from left section/curve module)
Fig. 64:
Connecting network and control voltage cables (from left section/curve module)
G
H
3 842 559 521/2018-07, MIT: ActiveMover, Bosch Rexroth AG
Assembly
89/172
557 186-64