Bosch Rexroth ActiveMover Assembly Instructions Manual page 158

Linear motor system
Hide thumbs Also See for Rexroth ActiveMover:
Table of Contents

Advertisement

158/172 Maintenance and servicing
5.
Start AMpro and
navigate to Diagnostic
Encoders
Encoder
Strip Setup.
6.
Click on the encoder on
which the fixing element
is centered
(odd number).
If the display is green
(±4 µm), the measuring
system is properly
calibrated.
If the display is red,
readjustment is needed.
7.
Slightly loosen the
measuring system
screws.
8.
Carefully adjust the value
with 2 long hex socket
wrenches on the inner
adjusting screws until
the display turns green.
Please note:
• When making
adjustments, it is
recommended to always
loosen one inner adjusting
screw and then slightly
tighten the other.
• Do not overtighten the
adjusting screws.
This could move the
calibration set.
9.
Tighten the measuring
system screws.
10.
Check the display again.
Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07
8
SW
Fig. 118:
Checking calibration set position (2)
6
7
SW
9
SW
M
= Nm
D
8
SW
557 186-118