130/172 Maintenance and servicing
Please note:
• Disconnect the power
cables from the system
components and not from
the power supply.
• The 230 V power supply
cable is removable.
• The power supply
mounting plate does not
need to be removed.
1.
Disconnect the power
supply cables from the
system components.
2.
Remove the plug
connector (230 V AC)
from the power socket.
3.
Remove the power
supply from the
mounting plate.
Mount and connect the
new power supply in
reverse order.
Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07
10.4.15 Replacing the power supply
1
Fig. 90:
Replacing the power supply
1
3
4x
SW
2
2