Adjusting The Secondary Measuring System - Bosch Rexroth ActiveMover Assembly Instructions Manual

Linear motor system
Hide thumbs Also See for Rexroth ActiveMover:
Table of Contents

Advertisement

This procedure uses the
primary measuring system
to adjust the secondary
measuring system.
Perform this procedure if:
• Positioning errors occur
in the WT and the primary
measuring system has
already been adjusted.
1.
After adjusting the
primary measuring
system, loosen the
knurled thumbscrew.
2.
Flip the knurled
thumbscrew up.
3.
Move the WT to the right.
4.
Slightly loosen the
measuring system screws.
5.
Install 2 screws as
adjustment aids.
Please note:
Do not overtighten the
helper screws. This could
bend the measuring system.
6.
Carefully move the
reference WT under the
reference system. Do not
let the WT collide with
the reference system.
7.
Flip the knurled
thumbscrew down.
8.
Gently press the WT to
the left and tighten the
knurled thumbscrew
slightly.
10.5.8

Adjusting the secondary measuring system

3
6
Fig. 119:
Adjusting the secondary measuring system (1)
Maintenance and servicing 159/172
2
1
5
6
8
7
3 842 559 521/2018-07, MIT: ActiveMover, Bosch Rexroth AG
4
SW
3x
SW
M2,5 x 10
557 186-119

Advertisement

Table of Contents
loading

Table of Contents