Start-Up; Initial Start-Up - Bosch Rexroth ActiveMover Assembly Instructions Manual

Linear motor system
Hide thumbs Also See for Rexroth ActiveMover:
Table of Contents

Advertisement

102/172 Start-up

Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07
8 Start-up

8.1 Initial start-up

Death or serious injury from failing to meet emergency stop safety circuit
specifications
The emergency stop safety circuits must meet the following specifications:
• Stop Category 1 per DIN EN 60204-1
The system should be completely surrounded by a guard as defined
in DIN ISO EN 14120.
• Access doors should have an electrical interlock and a locking mechanism.
• Access doors should remain locked for min. 5 s after power to the curve and
section module motors has been shut off.
• The necessary performance level under DIN EN ISO 13849 should be "d".
• It should not be possible to start the ActiveMover with the safety door open.
Sudden movements, falling objects
Injury due to sudden movements and falling objects.
Make sure the product has been correctly assembled by qualified personnel
(see page 10) before starting it up.
Malfunctions due to incorrect assembly and start-up
The product can be damaged and its service life shortened.
Start-up requires basic mechanical and electrical knowledge.
The product should only be started up by qualified personnel (see page 10).
Damage due to inadequate lubrication
The product can be damaged and its service life shortened.
Make sure there is a WT at least every 2 m along the transport path.
Give the lubricating felt of each WT an additional 20 drops of lubricant
(see Section 10.3.1).
Add lubrication to the V-rail. Use the same lubricant as the WT.
• Perform a risk assessment per DIN EN ISO 12100 before starting up a conveyor
system for the first time or returning one to service.
• Under the EU Machinery Directive (2006/42/EC), the transfer system must be
equipped with EMERGENCY STOP controls.
• Make sure all electrical connections are either used or capped. Make sure all
thread connectors and plug-in connectors are properly seated. All relevant
protective covers must be installed.
DANGER