166/172 Shutdown

Bosch Rexroth AG, MIT: ActiveMover, 3 842 559 521/2018-07
Loc.
LED
Color
B
13
Red
A
14
Red
1 PCBs (gateway) manufactured before mid-2016 that have not had a CPLD firmware update have
the following alert indications:
Loc.
LED
Color
G
10 TEMP
Yellow
and
and
F
11 TEMP
12 Shutdown
The product is a component that does not need to be separately shut down.
Accordingly, this section has been left blank.
Status
Normal status
ON
OFF
ON
OFF
Status
Normal status
ON
Fast flashing
OFF
Motor tem-
perature within
tolerance
Possible fault/error
Power supply shut off due to
excessive load current
• Short circuit in encoder PCB or
encoder connecting cable
Power supply for IR reading head
shut off due to excessive load
current
• Short circuit in IR reading head
or IR reading head connecting
cable
Possible fault/error
Defective thermistor detected
Max. operating temperature
exceeded