Goodrive20-EU series VFD
Function
Name
code
Parameter
P07.01
copy
Key function
P07.02
selection
Detailed instruction of parameters
Please remember all users' passwords.
Retreat editing state of the function codes and
the password protection will become valid in 1
minute. If the password is available, press
PRG/ESC to enter into the editing state of the
function codes, and then "0.0.0.0.0" will be
displayed. Unless input right password, the
operator cannot enter into it.
Note: Restoring to the default value can clear
the password, please use it with caution.
0: No operation
1: Upload the local function parameter to the
keypad
2: Download the keypad function parameter to
local address (including the motor parameters)
3: Download the keypad function parameter to
local address (excluding the motor parameter of
P02 and P12 group)
4: Download the keypad function parameters to
local address (only for the motor parameter of
P02 and P12 group)
Note: After finish 1 – 4, the parameter will restore
to 0 and the uploading and downloading does
not include P29.
0x00 – 0x27
Ones: QUICK/JOG key function
0: Null
1: Jogging
2: Switch display state via shift key
3: Switch between FWD/REV rotation
4: Clear UP/DOWN setting
5: Coast to stop
6: Switch running command ref. mode in order
7: Quick commission mode (based on
non-default parameter)
tens:
0: keys unlocked
1: Lock all keys
68
Function parameters
Default
Modify
value
◎
0
◎
0x01
Need help?
Do you have a question about the Goodrive20-EU VFD Series and is the answer not in the manual?
Questions and answers
Start stop time
The start-stop time for the INVT Goodrive20-EU VFD Series is not explicitly mentioned in the provided context. However, the "Pre-exciting time" (P03.25) is listed as a parameter that helps improve torque performance during startup, with a setting range of 0.000 to 10.000 seconds. If more specific start-stop time details are needed, they may be found in additional documentation.