Goodrive20-EU series VFD
Model
GD20-004G-4-EU
GD20-5R5G-4-EU
GD20-7R5G-4-EU
GD20-011G-4-EU
GD20-015G-4-EU
GD20-018G-4-EU
GD20-022G-4-EU
GD20-030G-4-EU
GD20-037G-4-EU
GD20-045G-4-B-EU
GD20-055G-4-B-EU
GD20-075G-4-B-EU
GD20-090G-4-B-EU
GD20-110G-4-B-EU
Note:
Select the resistor and power of the brake unit according to the data our company provided.
The brake resistor may increase the braking torque of the VFD. The resistor power in the
above table is designed on 100% braking torque and 10% braking usage ratio. If the users
need more braking torque, the brake resistor can decrease properly and the power needs to
be magnified.
C.7.2 Placing the brake resistor
Use shielded cables for brake resistor cables.
Install all resistors in a place where they will cool.
Brake
resistor at
Type of
100% of
brake unit
braking
torque (Ω)
122
89.1
65.3
44.5
32.0
Never use a brake resistor with a resistance below the minimum value
specified for the particular drive. The drive and the internal chopper are
not able to handle the overcurrent caused by the low resistance.
Increase the power of the brake resistor properly in the frequent braking
situation (the frequency usage ratio is more than 10%).
The materials near the brake resistor must be non-flammable. The
surface temperature of the resistor is high. Air flowing from the resistor is
of hundreds of degrees Celsius. Protect the resistor against contact.
Consumed power of the brake
10%
braking
0.6
0.75
1.13
1.65
2.25
27
3
22
3
17
5
13
6
10
7
8
8
6.5
11
5.4
14
4.5
17
161
Peripheral options and parts
resistor (kW)
50%
80%
braking
braking
3
4.13
5.63
8.25
13.2
11.3
14
17
23
28
34
41
56
68
108
83
132
Min.
brake
resistor
(Ω)
4.8
80
6.6
60
9
47
31
18
23
22
19
26
17
36
17
44
11.7
54
8
66
8
90
6.4
4.4
4.4

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive20-EU VFD Series and is the answer not in the manual?

Questions and answers

Star Electricals Vatva
February 22, 2025

Start stop time

1 comments:
Mr. Anderson
February 22, 2025

The start-stop time for the INVT Goodrive20-EU VFD Series is not explicitly mentioned in the provided context. However, the "Pre-exciting time" (P03.25) is listed as a parameter that helps improve torque performance during startup, with a setting range of 0.000 to 10.000 seconds. If more specific start-stop time details are needed, they may be found in additional documentation.

This answer is automatically generated

Table of Contents

Save PDF