Ascii Mode - INVT Goodrive20-EU VFD Series Operation Manual

Hide thumbs Also See for Goodrive20-EU VFD Series:
Table of Contents

Advertisement

Goodrive20-EU series VFD
7.3.1.4
Command code: 10H, continuous writing
Command code 10H means that if the master writes data to the VFD, the data number
depends on the "data number" in the command code. The max. continuous reading number is
16.
For example, write 5000 (1388H) to 0004H of the VFD whose slave address is 02H and 50
(0032H) to 0005H, the frame structure is as follows:
The RTU request command is:
START
ADDR
CMD
High bit of write data
Low bit of write data
High bit of data number
Low bit of data number
Byte number
High bit of data 0004H
Low bit of data 0004H
High bit of data 0005H
Low bit of data 0005H
Low bit of CRC
High bit of CRC
END
The RTU response command is:
START
ADDR
CMD
High bit of write data
Low bit of write data
High bit of data number
Low bit of data number
Low bit of CRC
High bit of CRC
END

7.3.2 ASCII mode

Command code: 03H (0000 0011), reading N words (N ≤ 16)
7.3.2.1
For instance: As for the VFD whose slave address is 01H, the starting address of internal
T1-T2-T3-T4 (transmission time of 3.5 bytes)
T1-T2-T3-T4 (transmission time of 3.5 bytes)
T1-T2-T3-T4 (transmission time of 3.5 bytes)
T1-T2-T3-T4 (transmission time of 3.5 bytes)
124
Communication protocol
02H
10H
00H
04H
00H
02H
04H
13H
88H
00H
32H
C5H
6EH
02H
10H
00H
04H
00H
02H
C5H
6EH

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive20-EU VFD Series and is the answer not in the manual?

Questions and answers

Star Electricals Vatva
February 22, 2025

Start stop time

1 comments:
Mr. Anderson
February 22, 2025

The start-stop time for the INVT Goodrive20-EU VFD Series is not explicitly mentioned in the provided context. However, the "Pre-exciting time" (P03.25) is listed as a parameter that helps improve torque performance during startup, with a setting range of 0.000 to 10.000 seconds. If more specific start-stop time details are needed, they may be found in additional documentation.

This answer is automatically generated

Table of Contents

Save PDF