Appendix A
Calibration Error Codes; Barcode Sensor
Table A-11 lists the various Error Code causes and solutions for the Barode Sensor Calibration Error.
Sensor
Upper Barcode Sensor
Lower Barcode Sensor
Maintenance Equipment
This portion provides product information for the UBA Pro Maintenance Equipment.
Maintenance Equipment
Figure A-2 Additional Maintenance Equipment
Requirements
Ltr.
EDP No.
a
280829
Reference Paper Handling
All JCM Reference Paper should be handled as follows:
1. Do not allow the Reference Papers to endure high temperatures and/or high humidity environments.
2. Store unused Reference Papers in their original Shipping Carton to avoid exposing them to direct
Sunlight and/or bright indoor light. Ensure that the Reference Papers being stored are not damaged as they are
replaced into their shipping carton.
3. Do not use Reference Paper containing damaged areas that are worn, dirty, wrinkled, distorted, discolored and/
or containing foreign objects or oil.
4. Use new Reference Paper every 400 times or when a Reference Paper doesn't meet the requirements defined
above. Incorrect calibration errors may occur when using Reference Paper that has been used for calibrating
more than 400 times.
P/N 960-000211R_Rev. A
UBA™ Pro Series Universal Banknote Acceptor
Table A-11 Barcode Sensor Calibration Error Codes
Error Code
03-00-00-00
Calibration Program process
failed while calibrating the
Upper Barcode Sensor.
03-00-00-01
Calibration Program process
failed while calibrating the
Lower Barcode Sensor.
a
Figure A-2 Additional Maintenance Equipment Requirements
Table A-12 Additional Maintenance Equipment Parts List
JAC No.
Description
N/A
Reference Paper (KS-101)
Solutions
•
Check that a correct Reference Paper is placed
in a proper direction. (Refer to "Placing
Reference Paper" on page 6-5.)
•
Check that a Reference Paper is not damaged
or dirty. (Refer "Reference Paper Handling" on
page A-14.)
•
Clean the relative Sensor. (Refer to "Cleaning
Procedure" on page 2-17.)
•
Check that a correct Reference Paper is placed
in a proper direction. (Refer to "Placing
Reference Paper" on page 6-5.)
•
Check that a Reference Paper is not damaged
or dirty. (Refer "Reference Paper Handling" on
page A-14.)
•
Clean the relative Sensor. (Refer to "Cleaning
Procedure" on page 2-17.)
Qty.
1
© 2020, JAPAN CASH MACHINE CO., LTD.
A - 1 4
Troubleshooting
Relative
Parts/Sensors
•
Barcode Sensor
•
Barcode Sensor
Remark