Calibration and Testing
Entrance Motor Operation Test
(Reverse)
To perform the Entrance Motor Operation Test in the
reverse rotation, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches as below (Figure 6-129).
Figure 6-129 Entrance Motor Operation Test
DIP Switches #5, #6, #8 ON
(Reverse) 1
ON
1
2
3
Figure 6-129 Entrance Motor Operation Test
(Reverse) 1
3. Apply electrical power.
4. Confirm that the
lit.
Figure 6-130 E
Figure 6-130 Entrance Motor Operation Test
(Reverse) 2
5. Lift up on the Upper Guide Access Lever to open
the UBA Pro's Cover
6. To start the Test, set the DIP Switch #8 to
(Figure 6-131).
Figure 6-131 Entrance Motor Operation Test
DIP Switch #8 OFF
(Reverse) 3
ON
1
2
3
Figure 6-131 Entrance Motor Operation Test
(Reverse) 3
7. The Rollers will start running in the reverse
direction when the Feed Motor functions prop-
erly.
Figure 6-132 Entrance Motor
Figure 6-132 Entrance Motor Operation Test
(Reverse) 4
8. Set the UBA Pro DIP Switch #8 to
test.
P/N 960-000211R_Rev. A
UBA™ Pro Series Universal Banknote Acceptor
4
5
6
7
8
Green
and
Red
Status LEDs are
Green Red
OFF
4
5
6
7
8
to end the
ON
Entrance and Feed Motors
Simultaneous Operation Test (For-
ward)
To perform the Motor Operation Test of the Entrance
Motor and the Feed Motor in the forward rotation at the
same time, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches as below (Figure 6-133).
Figure 6-133 Entrance and Feed Motors
DIP Switches #1, #6, #8 ON
Simultaneous Speed Test (Forward) 1
ON
1
2
3
Figure 6-133 Entrance and Feed Motors
Simultaneous Speed Test (Forward) 1
3. Apply electrical power.
4. Confirm that the
lit.
Figure 6-134 E
Figure 6-134 Entrance and Feed Motors
Simultaneous Speed Test (Forward) 2
5. Lift up on the Upper Guide Access Lever to open
the UBA Pro's Cover
6. To start the Test, set the DIP Switch #8 to
(Figure 6-135).
Figure 6-135 Entrance and Feed Motors
DIP Switch #8 OFF
Simultaneous Speed Test (Forward) 3
ON
1
2
3
Figure 6-135 Entrance and Feed Motors
Simultaneous Speed Test (Forward) 3
7. The Rollers will start running in the forward
direction when the Entrance and Feed Motors
function properly.
Figure 6-136 Entrance and
Figure 6-136 Entrance and Feed Motors
Simultaneous Speed Test (Forward) 4
8. Set the UBA Pro DIP Switch #8 to
test.
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 2 5
4
5
6
7
8
Green
and
Red
Status LEDs are
Green Red
OFF
4
5
6
7
8
to end the
ON
Section 6