Jcm Tool Suite Standard Edition Mode; Software Download; Figure 6-9 Normal Mode Selection; Figure 6-10 Test Mode Selection - JCM GLOBAL UBA Pro Series Operation And Maintenance Manual

Universal banknote acceptor
Table of Contents

Advertisement

Calibration and Testing
JCM Tool Suite Standard Edition
Mode
The following two (2) mode feature types exist in
the "
JCM Tool Suite Standard Edition
Normal Mode
Test Mode
"
" (DIP Switches All OFF) is a
Normal Mode
mode designed to provide the UBA Pro Operating
Software to be downloaded. 
The "
" contains three (3) available
Service Mode
choices shown in Figure 6-9 as follows:
Download (for downloading software)
Statistics (for observing log data)
Utility (for ICB and Bar Ticket settings)

Figure 6-9 Normal Mode Selection

Figure 6-9 Normal Mode Selection
"
" (DIP Switch #8
Test Mode
designed to perform UBA Pro Calibration and Per-
formance Testing. The "
five (5) available choices in its Pull-down Menu
shown in Figure 6-10 as follows:
Download (for downloading software)
Statistics (for observing log data)
Sensor Adjustment (for calibration)
Performance Test (for performance testing)
Utility (for ICB and Bar Ticket settings)

Figure 6-10 Test Mode Selection

Figure 6-10 Test Mode Selection

Software Download

The following two (2) procedures are available to
download the Software Program with a PC (JCM
Tool Suite Standard Edition):
The Software Program is loaded on the Unit
(Upgrade)
The Software Program is not loaded on the Unit
(Initial) (e.g., after replacing the CPU Board)
To download the Software Program, proceed as
follows:
1. Remove electrical power from the UBA Pro Unit.
P/N 960-000211R_Rev. A
UBA™ Pro Series Universal Banknote Acceptor
" package:
a
) is a mode
ON
" contains
Service Mode
a
2. When upgrading the Software, set DIP Switches
as below (Figure 6-11).
Figure 6-11 Software Download (Upgrade) 1
DIP Switches All OFF (Normal Mode)
ON
1
2
3
or
DIP Switch #8 ON (Test Mode)
ON
1
2
3
Figure 6-11 Software Download (Upgrade) 1
When downloading to a Unit (software not previ-
ously installed), set the DIP Switches as below
(Figure 6-12).
Figure 6-12 Software Download (Initial) 1
DIP Switches #6, #7, #8 ON
ON
1
2
3
Figure 6-12 Software Download (Initial) 1
3. Connect the UBA Pro Unit to the PC. (Refer to
Figure 6-1 for the Tool Requirements and Har-
ness Connector locations.)
4. Apply electrical power to the UBA Pro Unit.
5. The
Green
and
Red
JCM Tool Suite Standard 
6. Launch the "
" Application.
Edition
7. The Main Screen (Figure 6-13) will appear.
Figure 6-13 Software Download (Upgrade) 2
Figure 6-13 Software Download (Upgrade) 2
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 3
Section 6
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
Status LEDs will be lit.