Calibration and Testing
Calibration
This section provides instructions for performing a
calibration of the UBA Pro Sensors.
When to Calibrate
Calibration should be performed when one of the
following five (5) conditions occur:
•
The Unit is disassembled or reassembled.
•
One of Sensors is removed or replaced.
•
The UBA Pro Main Board is removed or replaced.
•
Dirt adheres to the Sensors (See "Cleaning
Procedure" on page 2-17.).
•
The Banknote Acceptance Rate becomes drastically
degraded.
Placing Reference Paper
NOTE: Do not touch the Paper Surfaces on
either side of the KS-101 Reference Paper
(Figure 6-20).
Figure 6-20 KS-101
Paper
Surface
Figure 6-20 KS-101 Reference Paper
Perform the following steps to properly place a
selected Reference Paper (KS-101) into the UBA
Pro Unit.
1. Lift up on the Upper Guide Access Lever to open
the UBA Pro's Cover (Figure 6-21 a).
2. Slide the selected Reference Paper (Figure 6-21
b) into the Unit until its Catch Edges evenly
touch both the left and right side of the Frame
(Figure 6-21
).
A
Figure 6-21 Placing Reference Paper 1
ID Sticker
Slide In
A
NOTE: Place the Reference Paper upward so
the ID Sticker is visible; otherwise, calibration
will not be performed correctly.
Figure 6-21 Placing Reference Paper 1
P/N 960-000211R_Rev. A
UBA™ Pro Series Universal Banknote Acceptor
KS-101
a
b
3. Firmly close the Upper Guide (Figure 6-22 a)
until it "clicks" in place, and ensure that both
sides are tightly closed and locked.
Figure 6-22 Placing Reference Paper 2
a
Click
Figure 6-22 Placing Reference Paper 2
Sensor Calibration
To calibrate the UBA Pro sensors, proceed as
follows:
1. Remove electrical power from the UBA Pro Unit.
2. Set DIP Switches as below (Figure 6-23).
Figure 6-23 Sensor Calibration 1
DIP Switch #8 ON
ON
1
2
3
Figure 6-23 Sensor Calibration 1
3. Connect the UBA Pro Unit to the PC.
NOTE: Refer to Figure 6-1 for the
necessary Tool and Harness
Connections and USB Cable Type
Requirements respectively.
4. Apply electrical power to the UBA Pro Unit.
5. The
Green
and
Red
6. Launch the "
JCM Tool Suite Standard Edition
Application.
7. Click and hold-down the "
Down Menu.
8. Select "
Sensor Adjustment
Figure 6-24 Sensor Calibration 2
Figure 6-24 Sensor Calibration 2
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 5
Section 6
4
5
6
7
8
Status LEDs will be lit.
"
" Pull-
Service Mode
" (Figure 6-24 a).
a