Section 8
iVIZION™2 Series Banknote Validator Foundation of Intelligent Validation
Status LED
Banknote Length Error
A Banknote was rejected
Green
because it was longer than
Flashes
the acceptable length
(13)
Reserved
Green
Flashes
(14)
Authentic Banknote Iden-
tify Error
Green
A Banknote was rejected due
Flashes
to the authentic Banknote
(15)
Validation result
Detected Holed-Note
Green
A Banknote was rejected
Flashes
because it was holed
(16)
Detected Worn-Out-Note
Green
A Banknote was rejected
Flashes
because it was worn out
(17)
Detected Dog-Ear-Note
Green
A Banknote was rejected
Flashes
because its corner was folded
(18)
Detected Dyed-Note
Green
A Banknote was rejected
Flashes
because it was inked
(19)
LED Reject Codes; Barcode Ticket
Status LED
Unconfigured Barcode Ticket
Barcodes cannot be detected or
Green
were detected on both sides
Flashes
facing up and down.
(1)
Format Error
A Barcode Ticket was rejected due
Green
to the number of characters and/
Flashes
or wide-to-narrow ratio
(2)
P/N 960-000231R_Rev. A
Table 24 LED Reject Codes; Banknote (Continued)
Error
•
Check that the Banknote is a proper
length
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
Table 25 LED Reject Codes; Barcode Ticket
Error
•
Check that a proper Barcode Ticket
is used.
•
Check that the Barcode Ticket is not
damaged or looks unnatural
(abnormal printing, etc).
•
Check that the relative Part(s) are
properly assembled and/or Harness
are connected.
•
Clean and calibrate the relative
Sensor(s).
•
Check that a proper Barcode Ticket
is used.
•
Check that the Barcode Ticket is not
damaged or looks unnatural
(abnormal printing, etc).
•
Check that the relative Part(s) are
properly assembled and/or Harness
are connected.
•
Clean and calibrate the relative
Sensor(s).
Solution
-
Solution
© 2022, JAPAN CASH MACHINE CO., LTD.
3 6
Troubleshooting
Relative Part/Sensor
•
Length of the Banknote
-
•
Sensors of the Validator
•
Sensors of the Validator
•
Sensors of the Validator
•
Sensors of the Validator
•
Sensors of the Validator
Relative Part/Sensor
•
Barcode Ticket
•
CIS
•
MGU Gear
•
Belts of the Validator
•
Motors of the Validator
•
Barcode Ticket
•
CIS
•
MGU Gear
•
Belts of the Validator
•
Motors of the Validator