Entrance Motor Speed Test (Forward); Entrance Motor Speed Test (Reverse) - JCM GLOBAL UBA Pro Series Operation And Maintenance Manual

Universal banknote acceptor
Table of Contents

Advertisement

Section 6

Entrance Motor Speed Test (Forward)

To perform the Entrance Motor Speed Test in the for-
ward rotation, proceed as follows:
1. Launch the Performance Test Program (see
page 6-8).
2. Select "
ENTRY_MOTOR_FWD_TEST
6-66 a).
3. Click the "
"
Start
66 b).
Figure 6-66 Entrance Motor Speed Test
b
a
Figure 6-66 Entrance Motor Speed Test
(Forward) 1
4. The measured time will appear in the
" area (Figure 6-67 a) on the Screen.
Motor
5. Confirm that the motor speed is in the acceptable
range: 550mm/sec to 1200mm/sec.
6. Click the "
"
Stop
67 b) to end the test.
Figure 6-67 Entrance Motor Speed Test
b
a
Figure 6-67 Entrance Motor Speed Test
(Forward) 2
P/N 960-000211R_Rev. A
UBA™ Pro Series Universal Banknote Acceptor
" (Figure
Screen Button (Figure 6-
"Entrance
Screen Button (Figure 6-
6 - 1 4

Entrance Motor Speed Test (Reverse)

To perform the Entrance Motor Speed Test in the
reverse rotation, proceed as follows:
1. Launch the Performance Test Program (see
page 6-8).
2. Select "
ENTRY_MOTOR_REV_TEST
6-68 a).
3. Click the "
"
Start
68 b).
Figure 6-68 Entrance Motor Speed Test
b
a
Figure 6-68 Entrance Motor Speed Test
(Reverse) 1
4. The measured time will appear in the "
" area (Figure 6-69 a) on the Screen.
Motor
5. Confirm that the motor speed is in the acceptable
range: 550mm/sec to 1200mm/sec.
6. Click the "
"
Stop
69 b) to end the test.
Figure 6-69 Entrance Motor Speed Test
b
a
Figure 6-69 Entrance Motor Speed Test
(Reverse) 2
© 2020, JAPAN CASH MACHINE CO., LTD.
Calibration and Testing
" (Figure
Screen Button (Figure 6-
"Entrance
Screen Button (Figure 6-

Advertisement

Table of Contents
loading

Table of Contents