Feed Motor Speed Test (Forward); Feed Motor Speed Test (Reverse) - JCM GLOBAL UBA Pro Series Operation And Maintenance Manual

Universal banknote acceptor
Table of Contents

Advertisement

Section 6

Feed Motor Speed Test (Forward)

To perform the Feed Motor Speed Test in the forward
rotation, proceed as follows:
1. Ensure that the Cash Box is properly installed.
2. Launch the Performance Test Program (see
page 6-8).
3. Select "
FEED_MOTOR_FWD_TEST
46 a).
4. Click the "
"
Start
46 b).
Figure 6-46 Feed Motor Speed Test (Forward)
b
a
Figure 6-46 Feed Motor Speed Test (Forward) 1
5. The measured speed will appear in the "
" area (Figure 6-47 a) on the Screen.
Motor Speed
6. Confirm that the motor speed is in the acceptable
range: 550mm/sec to 1000mm/sec.
7. Click the "
"
Stop
47 b) to end the test.
Figure 6-47 Feed Motor Speed Test (Forward)
b
a
Figure 6-47 Feed Motor Speed Test (Forward) 2
P/N 960-000211R_Rev. A
UBA™ Pro Series Universal Banknote Acceptor
" (Figure 6-
Screen Button (Figure 6-
Feed
Screen Button (Figure 6-
6 - 1 0

Feed Motor Speed Test (Reverse)

To perform the Feed Motor Speed Test in the reverse
rotation, proceed as follows:
1. Ensure that the Cash Box is properly installed.
2. Launch the Performance Test Program (see
page 6-8).
3. Select "
FEED_MOTOR_REV_TEST
48 a).
4. Click the "
"
Start
48 b).
Figure 6-48 Feed Motor Speed Test (Reverse)
b
a
Figure 6-48 Feed Motor Speed Test (Reverse) 1
5. The measured speed will appear in the "
" area (Figure 6-49 a) on the Screen.
Motor Speed
6. Confirm that the motor speed is in the acceptable
range: 550mm/sec to 100mm/sec.
7. Click the "
"
Stop
49 b) to end the test.
Figure 6-49 Feed Motor Speed Test (Reverse)
b
a
Figure 6-49 Feed Motor Speed Test (Reverse) 2
© 2020, JAPAN CASH MACHINE CO., LTD.