Recommended Wire; With Jcm External Harness; Not Using Jcm External Harness - JCM GLOBAL UBA Pro Series Operation And Maintenance Manual

Universal banknote acceptor
Table of Contents

Advertisement

Section 2

Recommended Wire

Caution: The wiring harness must be UL1061 AWG#22 with the specified length (the
acceptable electrical resistance of a wire: Approximately 150mΩ). For 12V DC, the thinner
or longer wiring harness than recommended specifications may cause the UBA Pro Unit to
reset caused by voltage drop.

With JCM External Harness

Connector

Not using JCM External Harness

POWER 1
P/N 960-000211R_Rev. A
UBA™ Pro Series Universal Banknote Acceptor
0.1m
UL1061
AWG#22
POWER 1
② ③
GND 2
3
20
Housing
NOTE: Refer to "Connector Pin Assignment" on
page 2-7 for details.
70107-0001
70066-0176
GND 2
3
20
2.5m or shorter
UL1061
AWG#22
JCM External Harness
Terminal
16-02-0115
16-02-0103
2.5m or shorter
UL1061
AWG#22
2 - 6
Power
Manufacture
Molex
Molex
Power
© 2020, JAPAN CASH MACHINE CO., LTD.