Table B-6

Ethernet status flags

Flag
Name
F-152
ETH Module OK
F-153
ETH Communications
Connection Established
F-154
ETH Write Data Watchdog Status On if the Watchdog timer has expired
F-155
ETH DHCP Failed
F-156
ETH BOOTP Failed
F-157
ETH IP Conflict
F-158
ETH Status 06
F-159
ETH Status 07
F-160
ETH Status 08
F-161
ETH Status 09
F-162
ETH Status 10
F-163
ETH Status 11
F-164
ETH Status 12
F-165
ETH Status 13
F-166
ETH Status 14
F-167
ETH Status 15
Description
On if the Ethernet module is operating
properly
On if a Modbus/TCP Ethernet connection
has been established from a host computer
without receiving a Write command from
any connected Modbus/TCP host
computer.
On if the Ethernet module is configured to
obtain its address from a DHCP server, but
either the assignment failed or a DHCP
server is not present on the network
On if the Ethernet module is configured to
obtain its address from a BOOTP server,
but either the assignment failed or a
BOOTP server is not present on the
network
On if another device on the network has the
same IP address as this Ethernet module
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use