2338_en_O
To mount the Operator Panel in an enclosure or cabinet:
1.
Clear any components around the desired mounting location on the enclosure.
76.2 ±0.2 mm
(3.00 ±0.008 in.)
Figure 2-12

Cutout dimensions for panel mounting

2.
Using an appropriate tool for the enclosure material, cut a 46.2 x 76.2 ±0.2 mm hole in
the enclosure (see Figure 2-12). Remove any burrs or sharp edges using a file or
appropriate tool.
NOTE:
Do not make the hole in the enclosure too large or the Operator Panel will pass through.
Do not drill holes for the mounting screws; they do not pass through the enclosure wall.
3.
Insert the Operator Panel into the hole from the front.
Display cable
Figure 2-13

Remote Operator Panel installation

Installation and connection of Nanoline components
Mounting
bracket
Mounting
screw
Nut
Gasket
Enclosure
wall
O K
4
9
3
8
2
7
1
6
0
5
IF T
S H
Operator
Panel
21