Vehicle Status (Status A - F) - Phoenix Contact EV Charge Control Basic User Manual

Charging controller
Table of Contents

Advertisement

EV Charge Control Basic
Table 5-3
Vehicle status according to IEC 61851-1
Vehicle
Vehicle
status
connected
No
A
B
Yes
C
Yes
D
E
Yes
F
Yes
*
Switch S2 (see
"Control Pilot wiring" on page
Va = measured voltage in the EV Charge Control Basic
Vb = measured voltage in the vehicle
**
EVSE = Electric Vehicle Supply Equipment (charging station)
††
The charging station can be set to an operational state using a signal at the Enable input, or the relevant Modbus command.
26 / 68
PHOENIX CONTACT
5.4

Vehicle status (status A - F)

*
S2
Charging
possible
Open
No
Open
No
Closed
Vehicle
ready
Open
No
Open
No
24)
Va
Description
12 V
Vb
= 0 V
A1
(12 V DC): No vehicle connected
(12 V PWM): Only temporary transition state,
A2
enters the A1 state
9 V
R2 detected
B1
(9 V DC): EVSE
B2
(9 V PWM): EVSE ready
6 V
R3 = 1.3 kΩ ±3%
Ventilation not required
C1
(6 V DC): EVSE not ready, charging process
aborted. Transition state; possible as a perma-
nent state only in the event of a simplified
Control Pilot.
C2
(6 V PWM): Charging process active
3 V
R3 = 270 Ω ±3%
Ventilation of the charging area required
D1
(6 V DC): EVSE not ready, charging process
aborted. Transition state; possible as a perma-
nent state only in the event of a simplified
Control Pilot.
D2
(6 V PWM): Charging process active
0 V
Vb = 0: EVSE
Mains problem or mains not available, short circuit on
the Control Pilot
EVSE not
EVSE not available
available
**
not ready yet
††
106377_en_04