Mechanical requirements
Vibration resistance according to IEC/EN 60068-2-6
Shock resistance according to IEC/EN 60068-2-7
EMC conformity according to 61000-6-2
ESD according to IEC/EN 61000-4-2
Electromagnetic fields according to IEC/EN 61000-4-3
Fast transient according to IEC/EN 61000-4-4
Surge voltage according to IEC/EN 61000-4-5
Conducted Interference IEC/EN 61000-4-6
Noise emissions according to 61000-6-4
EN 55011
2338_en_O
D 3

Conformance/approvals

1000000
100000
10000
0
1
2
Figure D-1

Relay life expectancy @ 120 V AC

5-10 Hz @ 3.55 mm, 10-150 Hz @ 2g
15g @ 11 ms all axis
Criterian B
4 kV contact discharge
8 kV air discharge
Criterian A
Field strength 10 V/M
Criterian A
All interfaces: 1 kV
Criterian B
All interfaces : 2 kV
Criterian B
0.5 kV symmetrical
Criterian A
Test voltage 10 V
Class A Industrial
3
4
5
6
7
8
9
Current (A)
10