7.3

Connection Examples

Pos: 39 /Serie 753 (WAGO-I/O-SYSTEM)/Hinweise zur Dokumentation/Hinweis zum Zubehörteil 753-120 (PROFIsafe) @ 20\mod_1411713230395_21.docx @ 164884 @ @ 1
Depiction of the I/O module with 753-120 Connector!
Information on this pluggable connection pertains to the 753-120 Connector,
which is not included with the I/O module.
Pos: 40.1 /Serie 750 (WAGO-I/O-SYSTEM)/Anschließen/Anschlussbeispiele/Sonderklemmen/Anschlussbeispiele 750-066x PROFIsafe/Anschlussbeispiele 750-066x/000-003 Einleitung, Digitale Eingänge Betriebsart "Standard" @ 7\mod_1266335192714_21.docx @ 50826 @ 3 @ 1
Warning against personal and property damage!
The use of the connection examples described in this section alone is not enough
to execute the safety function according to the SIL, Cat./PL determined from the
risk analysis. In connection with safe devices, sensors and actuators, additional
measures may be necessary to ensure the safety function.
This includes, for example, the appropriate wiring and parameterization of digital
inputs and outputs, as well as measures to exclude unforeseeable errors.
More information is available in the user manuals of the safe devices used.
The section "Connect Devices" > ... > "Connection Examples" generally
describes possible applications, in which the functions of the PROFIsafe I/O
module for implementation of a safety function are used.
For the digital inputs of the PROFIsafe I/O module, you can use the WAGO
parameterization tool during individual parameterization to select the "Standard"
or "Rotary table" operating mode. For more information, read the section
"Commissioning" > ... > "Parameterization of the PROFIsafe I/O Module with
the WAGO Parameterization Tool".
Depending on the operating mode of the PROFIsafe I/O module selected, you can
operate the following sensors on the digital inputs:
7.3.1
Connection Examples for Digital Inputs in the "Standard"
Operating Mode
If you have set the Operating Mode parameter of the PROFIsafe I/O module to
"Standard" using the WAGO parameterization tool, you can operate the inputs of
the PROFIsafe I/O module single- or two-channel.
Connection examples for the "Standard" operating mode are further examined
below.
Pos: 40.2 /Serie 750 (WAGO-I/O-SYSTEM)/Anschließen/Anschlussbeispiele/Sonderklemmen/Anschlussbeispiele 750-066x PROFIsafe/Anschlussbeispiel 750-066x/000-003 Not-Aus, einkanalig, Überschrift 4 + Warnung @ 7\mod_1269863045886_21.docx @ 54626 @ 4 @ 1