Page 5-24 LCD Programming
Revised 10/14
Power‐On Configuration (P4)
Two start‐up parameters are programmed at the Power‐On Configuration screen, and they are
set by choosing YES or NO:
Power‐On Motor Stop
At the Power‐On Motor Stop parameter, you decide if you prefer that the motor to be stopped
when the ASU is turned on (if so, choose YES) or if you prefer that the motor remain in its previ‐
ous mode when the ASU is turned on (choose NO).
Power‐On Heater Start
At the Power‐On Heater Start parameter, you decide if you prefer that the temperature zones
start heating automatically when the ASU is turned on (if so, choose YES) or if the heaters should
require a manual start when the ASU is turned on (choose NO). NOTE: If you choose NO, the
heaters will not begin to heat until the Enter Knob is pressed at start‐up.
From the System Configuration Menu: after turning the Input Wheel to select Power‐On Config‐
uration, press the Enter Knob. The first parameter (Power‐On Motor Stop) will be activated (see
illustration below). Press the Enter Knob to choose YES or NO.
Turn the Input Wheel to activate the second parameter (Power‐On Heater Start). Press the Enter
Knob to choose YES or NO.
After programming, press RETURN twice to return to the Overview Screen.
POWER-ON MOTOR STOP
POWER-ON MOTOR STOP
POWER-ON HEATER START
POWER-ON HEATER START
POWER ON CONFIGURATION
POWER ON CONFIGURATION
Parameter is activated (programmable).
Press Enter Knob to make selection.
YES
NO
This parameter may not be programmed until is is
activated. To activate, turn the Input Wheel.