Page 3-16
Installation
Revised 10/14
Storage and Disposal of the Application System
Temporary Storage of the Unit
1. Flush the adhesive application system with flushing fluid (PN L15653), following the instruc-
tions detailed in chapter 6 of this manual.
2. Clean or replace both the outlet filter and the primary filter, following the instructions
detailed in chapter 6.
3. Shut OFF all pressure and power sources.
4. Release residual air pressure.
5. Remove all residual adhesive and wipe components clean.
6. Remove all air lines and all power supply cables.
7. Pack the unit in a corrosion-proof manner.
8. Store the unit in such a way that it is protected from damage.
Disposal of the Unit
1. Shut OFF all pressure and power sources.
2. Release residual air pressure.
3. Remove all residual adhesive.
4. Remove all air and adhesive supply hoses and all power supply cables.
5. Dismantle all components and sort into mechanical and electrical components.
6. Arrange for all components to be recycled.
D15/D25/D45 V6 DCL ASU Manual #20-63
ITW Dynatec
Need help?
Do you have a question about the DYNAMELT D15 Series and is the answer not in the manual?