Temperature/ Pressure Conversion (P1)
After turning the Input Wheel to select the Temperature/ Pressure parameter, toggle between
Fahrenheit with PSI or Celsius with BAR readouts by pressing the Enter Knob.
Language Selection (P1)
After turning the Input Wheel to select the Language parameter, press the Enter Knob. The cur‐
rent language will flash. Turn the Input Wheel to select a language from the ones listed. Confirm
your choice by pressing the Enter Knob.
Zone Configuration (P1)
This menu configures the controller's temperature zones by listing the number of each type of
zone. Zone configuration is typically done at the ITW Dynatec factory and does not require pro‐
gramming by the user.
The Zone Configuration screen may be used to reload the ITW Dynatec factory default controller
parameters. To do so: turn the Input Wheel to select the Zone Configuration parameter and
press the Enter Knob. Press and hold the F1 button for five seconds, then press F2 to restore de‐
faults and wait for the controller to reboot.
Pump Configuration (P1)
This menu configures the ASU's pump by listing pump type. Most pump parameters are setup at
the ITW Dynatec factory. There are two user‐programmable pump parameters: Pump Enable
Temperature and Individual Pump Control. NOTE: D15/25/45 models have a maximum of two
pumps; D50/90 models have a maximum of four pumps.
Pump Enable Programming:
The Pump Enable Temperature serves as a low limit value. The controller will not allow the
pump to come on until its enable temperature is achieved. By doing so, it protects the pump,
pump shaft, motor and motor control module.
After pressing the Enter Knob to select the Pump Enable parameter, turn the Input Wheel to in‐
crease or decrease the pump enable temperature. Confirm your choice by pressing the Enter
Knob.
Individual Pump Control Programming:
When there are multiple pumps on a unit, they may be controlled individually since each pump
has its own external contact.
After pressing the Enter Knob to select the Individual Pump Control parameter, turn the Input
Wheel to select individual control, if desired, by choosing YES or NO. Confirm your choice by
pressing the Enter Knob.
LCD Programming Page 5-17
Revised 10/14
) or F1.